What new aircon piping costs
Operators price extra length per metre past the run they include, and quote the run itself by its length and how it is hidden. Concealed runs cost more than exposed ones.
Check how long a run each quote includes. Operators set that allowance differently, so two per-unit prices can cover very different lengths.
| Piping job | Market range in Singapore | Our rate |
|---|---|---|
| Piping run replaced, one indoor unit | Only two operators publish a per-run price, for different lengths; the run's length and concealment set it. | Quoted per job |
| Extra piping beyond the included length | $15–$120 per metre | |
| Whole system re-piped, System 2 to System 4 | Only two operators publish a whole-system price; the number of runs and how much is concealed set it. | |
| New trunking along the route | Fewer than three operators price trunking per metre; exposed or concealed trunking sets it. | Quoted per job |
An exposed run costs least. A run concealed in a wall or false ceiling costs more, and operators include different lengths before charging per metre.
Market ranges: published rates from 5 Singapore operators. Checked 20 Nov 2026.
Keep or replace: a checklist
Old piping can stay only if it passes every check. A single failure is enough to replace it.
| Check | Keep it if | Replace it if |
|---|---|---|
| Pipe size and wall gauge | They suit the new unit's manual | They are smaller or thinner than specified |
| Flare joints | Remade to suit the new refrigerant | Old flares left as they are |
| Pressure test | Holds with no drop | Pressure falls during the hold |
| Oil inside the old pipe | Clean | Dark oil, or the old compressor failed |
| Insulation | Whole and dry | Cracked, wet or with rust underneath |
| Route | Same rooms, same unit positions | Units are moving or the layout changes |
Why concealed piping costs more
Concealed piping runs inside a wall, a false ceiling or a boxed-up trunk. Replacing it means cutting into that finish and patching it afterwards.
Before a renovation closes a wall, ask whether the piping in it is new and tested. Replacing it later costs more than doing it while the wall is open.
When the piping question comes up
Each of these is a chance to test the old run before deciding. A pressure test answers whether it leaks; the other checks answer whether it suits the new unit.
- Replacing an old system, especially one on R22.
- A gas leak traced to a section of pipe rather than a joint.
- A renovation that moves the indoor or outdoor unit.
- Insulation that has cracked or is dripping along the trunking.