Minimum clearances to mark on renovation drawings
Built-in curtain pelmets look sleek in modern Singapore BTO and condo bedrooms, yet carpenters frequently extend the pelmet right into the corner where the aircon sits. Once the gypsum box or timber pelmet crowds the fan coil, airflow and servicing access both suffer.
Agree on exact clearance numbers between your interior designer and aircon installer during Trip 1 piping.
| Clearance zone | Recommended minimum | What goes wrong if cramped |
|---|---|---|
| Side gap to curtain pelmet / track | 150 mm to 200 mm | Blackout curtains blow sideways, block return air and wick cold moisture |
| Top intake gap to ceiling / pelmet lip | 100 mm to 150 mm | Choked top return grille raises fan noise and lowers cooling output |
| Bottom edge above window frame or sill | Keep full front casing clear of pelmet overhang | Front cover cannot swing upward to remove filters or drain pan |
| Front throw clear of sheer curtains | At least 300 mm clear swing path | Cold air bounces off heavy drapes back into thermostat sensor |
Why curtains near an aircon grow mould and cause short-cycling
When an indoor fan coil blows sideways across a thick night curtain, chilled air strikes the fabric and rebounds straight back into the unit's top temperature thermistor. The aircon reads the room as cold too early and cycles down while the far side of the bedroom stays warm.
Repeated blasts of cold air onto warm window glass behind the curtain also raise local condensation, encouraging dark mildew patches along the upper curtain header.
Practical fixes if the pelmet is already built
If your curtain pelmet already extends close to the aircon wall, stop the curtain track 200 mm short of the indoor unit edge or install a recessed roller blind on that outer window pane instead of pleated fabric drapes. Aim the inner vertical aircon vanes away from the window side.
Always check that a technician can still unclip the entire front cover and slide a wash canvas safely underneath during servicing.