Why single-glazed bay windows and damp planter walls hit dew point
Most older and mid-2000s Singapore condos feature single-pane bay window glass and concrete planter ledges watered daily by rain or potted plants. When an indoor fan coil blows 14°C supply air straight across those thin surfaces, the exterior glass face drops below the 26°C to 27°C tropical outdoor dew point and beads up outside, while leaky rubber gaskets pull muggy exterior air indoors to wet window sills and cushions.
Concrete planter box walls behave similarly: damp soil cools external masonry, and poorly insulated trunking passing near that chilled corner condenses moisture that homeowners often mistake for a leaking indoor coil.
| Where water appears | Underlying moisture driver | Targeted fix |
|---|---|---|
| Fogging and droplets on outside of bay glass | Indoor blast overchilling single-pane glass | Aim louvers away from glass and set 24°C–25°C |
| Puddles along interior marble sill and cushions | Worn window gasket leaking humid outdoor air | Replace rubber casement seals and latch tightly |
| Damp strip beside trunking near planter wall | Thin or torn foam insulation on refrigerant pipe | Re-insulate pipes with tight closed-cell armaflex |
| Peeling paint along lower exterior planter wall | External waterproofing seepage plus indoor chill | Check MCST waterproofing and reduce direct cold blast |
Separating architectural sweating from an actual aircon leak
Before booking an emergency drain flush, inspect the indoor unit underside and bottom wall edge with a dry tissue. If the fan coil bottom rim and drain pipe stay bone-dry while droplets form strictly across window mullions or cold marble bay ledges, the culprit is surface dew-point condensation rather than a choked condensate tray.
However, if water trails directly from trunking seams or drips straight beneath the indoor casing, degraded pipe insulation or a sluggish drain line requires technician attention right away.
Louvre deflection, setpoint tuning, and perimeter sealing
Redirect horizontal louvers away from bay window panes so supply air circulates across the sleeping zone first instead of scrubbing bare glass. Raising overnight thermostat settings from 20°C to 24°C or 25°C with a ceiling fan keeps bedrooms comfortable while lifting glass temperatures above outdoor dew point.
Closing blackout curtains or roller blinds loosely traps an insulating air buffer against bay glass, and renewing perished window rubber strips stops humid corridors of air from pouring onto cold marble sills.
Common questions
Why does condensation form on the outside of condo bay windows at night?
Can an aircon pipe running near a planter box cause wall dampness?
How can homeowners check if bay window water is from window seals or the aircon?