Which inverter aircon is most efficient for each room size?
Fujitsu leads three of the four bands on NEA's register snapshot of 17 September 2026. The leaders by weighted COP are the AOAG09CMTA, AOAG12CMTA and AOAH24CBTA, and the Panasonic U-18PRH1Z5 at 18,000 BTU.
A higher weighted COP means more cooling per unit of electricity. Annual energy is NEA's figure at eight hours a day.
9,000 BTU (2.3 to 3.0 kW): 25 registered models
The band for a study or common bedroom. Two Gree rows share one rating.
Scroll to see more columns
| Rank | Brand | Outdoor model | Cooling (kW) | Ticks | Weighted COP | Annual kWh |
|---|---|---|---|---|---|---|
| 1 | Fujitsu | AOAG09CMTA | 2.87 | 5 | 6.28 | 993 |
| 2 | Midea | MAS-1S09E | 2.90 | 5 | 6.07 | 1,098 |
| 3 | Gree | GWC09ATDXD-K6DNA3A/O | 2.65 | 5 | 6.02 | 969 |
| 3 | Gree | GWC-09Charmo/O | 2.65 | 5 | 6.02 | 969 |
| 5 | Mitsubishi Electric | MUY-GP10VF | 2.62 | 5 | 6.01 | 958 |
12,000 BTU (3.1 to 4.0 kW): 28 registered models
The band for a typical master bedroom.
Scroll to see more columns
| Rank | Brand | Outdoor model | Cooling (kW) | Ticks | Weighted COP | Annual kWh |
|---|---|---|---|---|---|---|
| 1 | Fujitsu | AOAG12CMTA | 3.59 | 5 | 5.90 | 1,326 |
| 2 | Gree | GWC-12Charmo/O | 3.48 | 5 | 5.83 | 1,302 |
| 3 | Panasonic | CU-XU12XKZ | 3.63 | 5 | 5.67 | 1,472 |
| 4 | Mitsubishi Electric | MUY-GA13VF | 3.61 | 5 | 5.66 | 1,407 |
| 5 | Gree | GWC-12SP/O | 3.43 | 5 | 5.59 | 1,332 |
18,000 BTU (4.6 to 5.6 kW): 26 registered models
The band for a small living room or a large master bedroom. The register names only the outdoor unit, so confirm the indoor type, wall, ceiling or ducted, in the quote.
Scroll to see more columns
| Rank | Brand | Outdoor model | Cooling (kW) | Ticks | Weighted COP | Annual kWh |
|---|---|---|---|---|---|---|
| 1 | Panasonic | U-18PRH1Z5 | 4.95 | 4 | 6.08 | 1,840 |
| 2 | Daikin | RZF50DVMG | 5.02 | 4 | 6.05 | 1,845 |
| 3 | Hitachi | PAS-2.0UFASNQ1 | 5.04 | 4 | 6.02 | 1,916 |
| 4 | Mitsubishi Electric | SUY-ZM50VA-SG | 5.11 | 5 | 5.99 | 1,910 |
| 5 | Mitsubishi Electric | MUY-GA18VF | 4.65 | 5 | 5.79 | 1,810 |
24,000 BTU (5.9 to 7.5 kW): 31 registered models
The band for a large living room or open space.
Scroll to see more columns
| Rank | Brand | Outdoor model | Cooling (kW) | Ticks | Weighted COP | Annual kWh |
|---|---|---|---|---|---|---|
| 1 | Fujitsu | AOAH24CBTA | 7.26 | 5 | 6.04 | 2,657 |
| 2 | Fujitsu | AOAG24CMTA | 6.20 | 4 | 5.78 | 2,459 |
| 3 | Mitsubishi Electric | SUY-M60VA-SG | 6.11 | 4 | 5.70 | 2,453 |
| 4 | Daikin | RZFV71AVMG | 6.90 | 5 | 5.56 | 2,792 |
| 4 | Daikin | RZF60DVMG | 5.93 | 4 | 5.56 | 2,429 |
How the list was built
The data is NEA's air-conditioner register, downloaded on 17 September 2026. It includes single splits with a weighted COP and a registration valid past 31 December 2026.
NEA defines weighted COP as 0.4 times full-load COP plus 0.6 times half-load COP. Its minimum for a single-split inverter is 4.86, and every model listed is above 5.5.
A 4-tick model can outrank a 5-tick one here, because the list ranks on weighted COP. Ties share a rank.
- Not measured: noise, reliability, parts supply or installation quality.
- Not a sales ranking: registrations say nothing about units sold.
- Outdoor model only: the indoor model comes from the quote.
Which band fits which room
Size first, efficiency second. These are the starting bands the site's BTU calculator uses.
Sun exposure, ceiling height and an open kitchen can move a room up a band. The BTU sizing guide covers those adjustments.
| Room | Floor area | Starting band |
|---|---|---|
| Study or common bedroom | Up to 150 sqft | 9,000 BTU |
| Master bedroom | 150 to 220 sqft | 12,000 BTU |
| Small living room or large master | 220 to 320 sqft | 18,000 BTU |
| Large living room or open space | 320 to 450 sqft | 24,000 BTU |
Reading the numbers without being misled
Compare annual energy only within a band. At 9,000 BTU, the MUY-GP10VF uses less than the top Fujitsu because it is smaller, not more efficient.
The first and fifth models in each band are 0.27 to 0.48 apart on weighted COP. At that spread, sizing and installation are the larger decisions.
The register is a snapshot. Check a model's current entry on NEA's search before buying.