Why is my Daikin not cold?
Daikin Singapore lists a dirty air filter and something blocking the indoor or outdoor unit. It adds a temperature set too high, open windows or doors, the airflow direction and the remote not in cooling mode, then faulty parts.
If those are ruled out, the fault is inside the system. A U0 code on many Daikin inverters means the unit has detected a refrigerant shortage.
| Cause | What you notice | Who fixes it |
|---|---|---|
| Dirty filter or coil | Weak airflow | Servicing |
| Blocked indoor or outdoor unit | Weak airflow, room slow to cool | A technician clears the airflow |
| Settings or remote mode | Fan only, no cooling | Check the mode and setting |
| Refrigerant shortage, often a leak | U0 code; cooling fades over weeks | Leak test, repair, recharge |
| Sensor, valve or compressor fault | Code shown or unit stops | Diagnosis and part replacement |
What the U0 code means
Daikin's service manual for its FTXS-L and FDXS-L inverter series describes U0 as a refrigerant shortage. The unit detects it from the compressor's current and speed, the discharge pipe temperature and the expansion valve opening. Its listed causes are a disconnected thermistor, a closed stop valve, a leak, poor compressor performance or a faulty electronic expansion valve.
So U0 does not always mean a leak, but a leak is the first thing to test for. A top-up without finding it fixes nothing.
Repair or replace
A sensor, a valve or a joint leak is normally worth fixing. When an older Daikin has a compressor fault, price a new system against the repair.
Boards are replaced, not repaired, and only after the sensors are ruled out.