Daikin Aircon Not Cold: Inverter Causes and Repair Decisions

A Daikin inverter that stops cooling either has an airflow or settings problem, which is quick to fix, or a fault in the refrigerant circuit. Daikin's own guidance separates the two.

On this page

Why is my Daikin not cold?

Daikin Singapore lists a dirty air filter and something blocking the indoor or outdoor unit. It adds a temperature set too high, open windows or doors, the airflow direction and the remote not in cooling mode, then faulty parts.

If those are ruled out, the fault is inside the system. A U0 code on many Daikin inverters means the unit has detected a refrigerant shortage.

Why is my Daikin not cold? summary table
CauseWhat you noticeWho fixes it
Dirty filter or coilWeak airflowServicing
Blocked indoor or outdoor unitWeak airflow, room slow to coolA technician clears the airflow
Settings or remote modeFan only, no coolingCheck the mode and setting
Refrigerant shortage, often a leakU0 code; cooling fades over weeksLeak test, repair, recharge
Sensor, valve or compressor faultCode shown or unit stopsDiagnosis and part replacement

What the U0 code means

Daikin's service manual for its FTXS-L and FDXS-L inverter series describes U0 as a refrigerant shortage. The unit detects it from the compressor's current and speed, the discharge pipe temperature and the expansion valve opening. Its listed causes are a disconnected thermistor, a closed stop valve, a leak, poor compressor performance or a faulty electronic expansion valve.

So U0 does not always mean a leak, but a leak is the first thing to test for. A top-up without finding it fixes nothing.

Repair or replace

A sensor, a valve or a joint leak is normally worth fixing. When an older Daikin has a compressor fault, price a new system against the repair.

Boards are replaced, not repaired, and only after the sensors are ruled out.

Common questions

Why is my Daikin aircon running but not cold?
Daikin Singapore lists a dirty air filter, a blocked indoor or outdoor unit, the temperature set too high, open windows or doors, the airflow direction and the remote not being in cooling mode as common causes. If those check out, a part or the refrigerant circuit is the likely fault.
What does the U0 code mean on a Daikin aircon?
In Daikin's service manual for its FTXS-L and FDXS-L inverter series, U0 means a refrigerant shortage. The manual lists the possible causes as a disconnected thermistor, a closed stop valve, a refrigerant leak, poor compressor performance or a faulty electronic expansion valve, so the system is tested before gas is added.
Can I fix a Daikin U0 error with a gas top-up?
Not reliably. A U0 code points to a refrigerant shortage, which usually means a leak, but Daikin also lists sensor, valve and compressor causes. A top-up without finding the cause refills a leaking circuit or misses the real fault, so the system is tested first.
Is a Daikin aircon worth repairing when it is not cold?
Usually, if the cause is a filter, a sensor, a valve or a joint leak. If an older Daikin has a failed compressor, price a replacement system serving the same rooms against the repair quote, because the coils, board and fan motors are just as old.