What fixing a not-cold aircon usually costs
It depends on the cause, and the causes run from a dirty coil to a failed compressor. Most not-cold faults sit at the cheaper end of that list.
The table puts each cause beside the sign that points to it, with Snowflake Aircon Services' rates and published market ranges.
Scroll to see more columns
| Cause and repair | Market range in Singapore | Our rate | Sign that points to it |
|---|---|---|---|
| Dirty coil, chemical servicing | $80 for one unit; $70 each for two; $60 each for three or more | Weak, warm airflow; musty smell | |
| Low gas, R32 top-up after any leak is sealed | $120–$200 | Ice on the pipes; cooling fades over weeks | |
| Low gas, R410A top-up after any leak is sealed | $80–$150 | Ice on the pipes; cooling fades over weeks | |
| Faulty temperature sensor (thermistor) | Operators quote it after testing; the sensor's position and the model set it. | Quoted per job | Unit stops cooling early or blinks a code |
| Indoor fan motor, wall-mounted unit | $120–$400 per job | $220–$320 | Fan slow, noisy or stopping |
| Compressor or condensing unit | $300–$1,500 per job | Quoted per job | Outdoor unit hums or stays silent |
| Diagnostic visit to find the cause | $30 / visit | Any of the above |
Rows run from the cheapest likely cause to the dearest. A gas top-up is only a repair once any leak is found and sealed; otherwise the gas escapes again.
Market ranges: published rates from 4 Singapore operators; published rates from 6 Singapore operators. Checked between 18 Nov 2026 and 20 Nov 2026.
Start with the cheapest cause
Check when the filters were last cleaned. If they have gone weeks without a wash, airflow may be the whole fault, and a servicing fixes it.
If the filters were clean, a coil that has not had a chemical service in a year or more is the next likely cause. It is also the cheapest repair on the list.
Why a top-up alone is the wrong fix
Gas does not get used up. If the gas is low, it has leaked, and a top-up only refills a circuit that is still leaking.
Ask for the leak to be found first. What that adds to the bill is in the gas leak repair cost guide.
Signs the bill will be at the top end
Listen to the outdoor unit from indoors, or from a window, while the aircon runs. What it does narrows the cause before anyone opens it.
- Outdoor fan turns, no cold air indoors: gas or a sensor.
- Outdoor unit hums with its fan still: a capacitor on non-inverter units, otherwise the board or the compressor.
- Outdoor unit stays silent: power, the board or the compressor.
- Indoor fan weak even with clean filters: the indoor fan motor or a fouled blower.
When to repair, and when to price a replacement
A compressor fault on a unit past ten years old is where the sums turn. Get a replacement quote for the same rooms before approving the repair, since every other part is just as old.