What do Daikin's extra remote symbols do?
Daikin ARC-series remotes shipped with Singapore iSmile and iSmileEco+ wall units add six signature controls on top of Cool, Dry and Fan. Each control alters compressor limits, louver geometry or post-shutdown coil drying.
Two icons, Econo and Outdoor Unit Quiet, actively limit maximum compressor output. Leaving either engaged during a hot Singapore afternoon reduces cooling capacity on purpose, even when the thermostat shows 23°C.
| Daikin symbol or button | What it changes on the unit | When to switch it on or off |
|---|---|---|
| Econo (house or leaf icon) | Caps maximum running current and compressor frequency to cut peak draw | Use once the room is cool; turn off when cooling a hot room quickly |
| Powerful (flexed figure) | Runs fan and compressor at maximum output for 20 minutes, then reverts | Use briefly when returning to a hot west-facing HDB bedroom |
| Comfort (person with upward wave) | Tilts the flap upward in Cool mode so cold air avoids blowing onto skin | Keep on in compact bedrooms where the unit sits near the bed |
| Indoor Quiet (tree or whisper icon) | Drops indoor blower speed below low setting to cut bedroom noise | Use for light sleepers; avoid if airflow already feels weak |
| Mold Proof / Streamer | Runs low-heat or fan-only drying and Streamer discharge after shutdown | Helpful in humid Singapore flats to slow coil slime, not a substitute for servicing |
Why Daikin's fan keeps running after you switch off
A Daikin unit whose indoor fan keeps spinning gently after pressing OFF is usually running its Mold Proof dry cycle. Daikin's FTKM operation manual notes that the drying run clears residual moisture from the evaporator coil before closing the flap.
This dry cycle lasts up to roughly an hour depending on the series and does not signal a stuck relay. If the fan never stops after two hours or emits a damp odour anyway, the coil needs physical cleaning rather than a longer dry run.
Motion sensor and comfort airflow in Singapore flats
Select Daikin Singapore models carry an Intelligent Eye infrared sensor on the front panel. When the sensor detects no movement for 20 minutes, it shifts the setpoint up by 2°C to save electricity.
In a bedroom with a still sleeper under a blanket, Intelligent Eye can sometimes misread inactivity and raise the temperature overnight. Disabling the sensor icon on the remote restores a fixed setpoint immediately.
What to do when Daikin settings do not fix weak cooling
Clear Econo, Quiet and Intelligent Eye icons, confirm the snowflake Cool symbol at 24°C, and listen for the outdoor condenser. Daikin Singapore's FAQ also flags flat AAA batteries and blocked indoor receivers as the first checks whenever a handset fails to beep the unit.
When a Daikin still blows warm air or flashes its green operation lamp after settings are verified, use the Daikin blinking light guide to retrieve the stored code before booking aircon repair. Snowflake Aircon Services checks airflow, drain lines and refrigerant readings on site instead of guessing from remote symptoms.