A genuine wall-mounted chemical overhaul dismantles eight physical assemblies off the wall: outer shell, mesh filters, swing louvres, front drain pan, electrical PCB box, blower wheel, fan motor shaft clearance, and the evaporator coil chassis. Wall-bag spraying alone is chemical servicing, not an overhaul.
Why Some Crews Charge Overhaul Prices for In-Place Sprays
Wall-hung chemical washing takes twenty minutes with a plastic funnel sheet, whereas a proper strip-down requires roughly sixty minutes per fan coil plus pump-down or careful flare-nut handling. Shortcuts happen when operators hang a canvas bag, mist coil foam onto the front face, and invoice S$150 anyway.
Resale home buyers who have never watched a teardown often assume heavy foam and loud water pumps equal a full overhaul. Yet without lifting the evaporator fin block and blower barrel away from the wall bracket, rear sludge stays trapped inside the housing.
Watching what physically leaves your bedroom wall makes fake upsells unmistakable within ten minutes.
The 8 Components Dismantled in a Real Chemical Overhaul
Every wall-mounted residential split unit from Mitsubishi Starmex, Daikin, Panasonic, or Midea follows this core teardown sequence. Technicians lay separated plastic covers, louvres, trays, and barrels neatly before carrying wet-safe pieces to the bathroom.
Electrical modules stay dry on clean cloths inside the bedroom while aluminium coils undergo two-sided chemical immersion and plain-water flushing.
Scroll to see more columns
| Component | Removed from wall? | Hidden dirt cleared | What homeowners see |
|---|---|---|---|
| 1. Pre-filters and deodorising strips | Yes, lifted out first | Loose fluff and kitchen dust | Rinsed clear and air-dried |
| 2. Outer plastic casing and intake panel | Yes, unscrewed fully | Yellow grease and corner lint | Washed inside toilet wet zone |
| 3. Motorised swing louvres and blades | Yes, unclipped carefully | Dark mould dots along vent lips | Scrubbed clean without snapping pins |
| 4. Detachable front condensation drain pan | Yes, unlatched from chassis | Sludge pools and algae jelly | Both corners and spout brushed bare |
| 5. PCB control box and wiring harness | Yes, unplugged and kept dry | Protected from chemical splash | Laid on dry towel away from water |
| 6. Cross-flow cylindrical blower wheel | Yes, slid off motor shaft | Compacted black slime in blade cups | Hand-brushed rib by rib in bathroom |
| 7. Evaporator coil fin block | Yes, brought down for two-sided soak | Rear-fin biofilm and baked oil | Flushed front and back until clear |
| 8. Rear back-casing and secondary drip trough | Yes, stripped chassis washed bare | Back-pan jelly and wall-side spores | Clean plastic wall frame before remount |
Pump-Down Safety, Fan Bearings, and Leak Checks on Remount
When the copper flare unions are disconnected to bring the entire indoor assembly down, technicians first pump refrigerant safely back into the outdoor condenser so zero R32 or R410A escapes. After reattaching flare nuts, vacuuming and soap-bubble joint checks ensure tight seals.
Before sliding the clean blower drum back onto the motor shaft, technicians lubricate the opposite rubber bearing sleeve and check motor spin resistance so bedroom noise stays whisper-quiet.
Inspecting fragile plastic mounting hooks and thermistor clips during reassembly also prevents hairline vibration buzz once cooling restarts.
How to Verify a Genuine Wall-off Overhaul Before Paying
Clarifying scope over WhatsApp prevents awkward disputes once technicians set up ladders in your HDB flat or condo. Genuine full dismantles take about an hour per unit and leave dismantled components laid neatly for bathroom washing.
Verify these four markers before agreeing to any overhaul quote.
- Ask directly whether the indoor coil, blower drum, and plastic back frame come down off the wall bracket.
- Expect roughly 60 minutes per wall-mounted unit rather than a rushed 15-minute spray-and-go job.
- Check that the PCB housing is disconnected and set aside dry instead of loosely wrapped with a plastic bag.
- Confirm transparent tiered rates upfront, such as Snowflake Aircon Services' S$150 single-unit fee, S$125 each for two units, and S$115 each for three or more.
Common Questions
Does every chemical overhaul require disconnecting the copper refrigerant pipes?
Will disconnecting pipes during an overhaul cause my aircon to lose gas?
How is a chemical overhaul different from chemical servicing in Singapore?
Why must the PCB box be removed before chemical washing begins?