On this page
Quick summary
A five-minute phone clip at HDB move-in and move-out records louvre sweep, dry drain pans, remote beeps, and air temperature drops across every room. Dated footage and proper bills prevent unfair deposit cuts.
Why Phone Video and Probe Tests Beat Paper Inventory Ticks
Flat handover forms often shrink aircon status down to one ticked box. Weeks later, a stiff flap or slow leak sparks arguments over who caused the fault.
One short unedited phone video walking room by room locks proof on a clear date stamp. Stay indoors on floor level and keep off outdoor ledges and live power boxes.
Follow the 5-Minute Move-in and Move-Out Handover Checklist
Set each wall unit to cool mode at 18 degrees and top fan speed for ten minutes. Then film these four quick checks across every room:
Scroll to see more columns
| 5-minute check step | What phone video captures | Pass benchmark in SG flats | Action if test fails |
|---|---|---|---|
| Remote & beep response | Press on, mode, and fan speed keys | Clear indoor beep and full LCD icons | Swap batteries; log receiver fault early |
| Swing louvres & noise | Cycle vertical flap open and closed | Smooth vane sweep without clicking | Flag stuck motor in defect list immediately |
| Drain pan & wall dryness | Pan torch below casing and trunking | Dry underside, steady flow at floor trap | Book drain clear before keys return |
| Digital probe delta-T | Hold probe 5 cm at intake then outlet | 8 to 12 degree drop across fins | Below 6 degrees needs wash or S$30 check |
Send Footage Inside the Defect Window to Lock Baseline Proof
New tenants should email or chat the unedited video to their agent within the defect period. Early proof of rattles, dim screens, or weak airflow stays outside tenant liability.
Leaving tenants gain equal cover by filming right after final cleaning, three to seven days before key return. Pair the video with quarterly invoices so normal wear never triggers unfair claims.
Compare HDB Handover Servicing Rates and Fault Check Fees
Clearing dirt or drain slime before inspection day saves far more than landlord-billed deductions:
- General handover cleaning charges S$50 for a lone HDB blower. Cleaning a pair totals S$60, while booking three-plus heads settles at S$25 per handover head carrying 14-day warranty assurance.
- Sour move-out odours clear through chemical servicing. Single blowers bill S$80, paired blowers cost S$70 each, and three or more drop to S$60 per handover unit with 60-day warranty terms.
- Slime-choked drain pans demand full strip-down overhauls. One messy FCU bills S$150, two FCUs run S$125 each, and three-plus FCUs fall to S$115 per handover FCU with 90-day warranty terms.
- Weak delta-T drops under 6 degrees warrant a S$30 inspection before key return. That fee drops off repair invoices, while yearly plans get S$0 fault checks.
Check Your Diagnostic or Servicing Price
Tap your job, unit count, and home type for our published Singapore rate — then send the pre-filled message on WhatsApp.
Published Singapore estimate
$75 nett
Published wall-mounted rate: $25 per unit × 3 units (no GST or area surcharge).
Includes 14-day workmanship warranty on general wash (60 days on chemical wash). Units above 12,000 BTU +$10/unit.