Step-by-step wireless remote check
Stand directly below the Daikin indoor unit with the flashing green operation lamp and make sure fresh batteries sit inside the handset. Aim the transmitter straight at the receiver window so every signal registers cleanly.
This built-in procedure is strictly a read-only diagnostic check. It queries stored fault memory without opening any covers or clearing the active error record.
| Step | Remote action | What you see and hear |
|---|---|---|
| 1 | Point remote at the blinking FCU and press and hold CANCEL for 5 seconds. | The LCD display switches to a flashing 00 diagnostic prompt. |
| 2 | Tap CANCEL once per second to step through each stored fault code. | Short single beeps mean no match; two quick beeps mark a related fault group. |
| 3 | Stop immediately when one long continuous beep plays from the indoor unit. | The two-character code shown on the screen is the active Daikin fault. |
| 4 | Hold CANCEL for 5 seconds again or wait 60 seconds to exit. | The handset returns to normal temperature display automatically. |
Why you must keep wall switches untouched
Resist the temptation to flip the wall isolator switch off and on or push a tripped circuit breaker back up before reading the fault. Cutting mains power wipes volatile fault logs on several Daikin models and forces technicians to wait for an intermittent trip to reoccur.
When the unit shows 00 with a long beep, no active error is currently stored. If cooling still feels weak despite a 00 readout, clogged filters, fouled evaporator coils, or gradual refrigerant loss may be present without triggering an electronic lock.
What to send before booking service
Write down the exact two-character code such as U4, U0, A6, or E5, and check whether neighbouring bedrooms on your multi-split also flash or cool poorly. Photograph the barcode nameplate on the underside or right flank of the indoor unit.
Snowflake Aircon Services can review that photo and retrieved code over WhatsApp so technicians arrive prepared with testing meters and matched spares.