Mitsubishi Heavy Industries (MHI) SRK indoor units signal hardware lockouts by pairing green RUN and orange TIMER indicator lamps. Counting both lamps from floor level separates indoor thermistor faults, fan stoppages, and outdoor communication drops. Recording the exact pair speeds up MHI spare checks across Singapore HDB flats and condos.

On this page

Quick summary

Mitsubishi Heavy Industries (MHI) wall units report faults using two lamps together: the green RUN light and orange TIMER light. Watch which lamp stays solid while counting flashes on the other across two pause cycles. Logging both states prevents brand mix-ups with Mitsubishi Electric.

How to Count Mitsubishi Heavy RUN and TIMER Flashes Safely

First confirm your wall casing reads Mitsubishi Heavy Industries with an SRK model code, rather than Mitsubishi Electric Starmex. Both are separate Japanese makers with distinct blink tables and control boards.

Leave your room isolator switched on while observing, because cutting mains power clears the live blink pattern. Stand on the floor about 1.5 metres away and soften overhead glare so both tiny indicator lenses stay crisp.

  • Look at both lamps at once: note whether the green RUN lamp is lit solid, blinking in counted bursts, or flashing non-stop.
  • Check the orange TIMER lamp beside it at the same moment to see if it stays solid or blinks in bursts.
  • Wait for the dark break between bursts, then count each flash aloud across two full cycles to confirm the exact number.
  • Record a steady 10-second phone video showing both lenses clearly, then switch the unit off with the wireless remote.

Pass or Fail Self-Check for MHI RUN and TIMER Patterns

MHI residential self-diagnosis charts pair RUN flashes against TIMER flashes to separate indoor and outdoor zones. Compare your counted lamp pair against the verified SRK table below.

Scroll to see more columns

Pass or fail self-check for MHI RUN and TIMER patterns summary table
RUN and TIMER lamp pairPass or failVerified MHI fault meaningSafe next step
RUN flashes slowly with TIMER off during cool startupPass (normal cycle)Standard standby, frost protection, or mode changeover delayWait 5 minutes and check room airflow; wash dust screens if weak
RUN blinks 1x or 2x while TIMER stays litFail (stop DIY)Indoor coil sensor (E6) or room air sensor (E7) wire or plug faultSwitch off that head via handset; arrange sensor resistance testing
RUN blinks 6x while TIMER stays litFail (stop DIY)Indoor fan motor fault (E16) or loose motor harnessKeep unit powered down to avoid board damage; book inspection
RUN blinks 7x while TIMER stays litFail (stop DIY)Insufficient refrigerant, shut service valve, or indoor coil sensor errorStop cooling mode; request manifold pressure and leak check
RUN stays lit while TIMER blinks 5x or 6xFail (stop DIY)Compressor overheat (E36 at 5x) or signal transmission fault (6x)Avoid repeated isolator resets; log whether other rooms cooled
RUN blinks 2x and TIMER blinks 2x togetherFail (stop DIY)Outdoor compressor rotor lock (E60) or outdoor inverter board faultShut off via remote and arrange metered outdoor diagnosis

Singapore EMA, HDB, and MOM Safety Stop-Line

Keep every check on the bedroom floor. Never pry open the SRK wiring box to pull sensor plugs or probe fan pins while live 230V power feeds the unit. EMA rules bar DIY work on live circuits.

Never step onto HDB ledges or lean past condo rails to view outdoor SCM board lights. MOM and BCA rules require fall gear for all high-rise outdoor work.

Choosing MHI Fault Diagnosis Versus Routine Servicing

MHI spares are stocked less widely locally than mainstream brands, so accurate first-visit checks save days of wait time. Repeating RUN and TIMER lockouts need metered fault testing rather than a filter wash. Snowflake Aircon Services bills S$30 for an MHI fault check and drops that charge to zero when repair goes ahead. For healthy MHI sets with no active blinks, routine cleaning starts at S$50 for one room, dropping to S$30 per blower for two and S$25 for larger multi-room flats. Deep chemical washes sit at S$80 (single), S$70 (pair), and S$60 (three or more), while complete overhauls run S$150, S$125, and S$115.

Include these four clues when WhatsApping Snowflake:

  • State both lamp states explicitly, such as RUN solid with TIMER blinking 6 times.
  • Attach your 10-second phone clip so technicians verify burst pacing before arriving.
  • Lift the front cover gently and snap the bottom-right SRK model sticker (or invoice copy).
  • Note if the unit sits on an SCM multi-split and whether sibling bedrooms still blow cold.

Common Questions

Are Mitsubishi Heavy Industries blink codes the same as Mitsubishi Starmex?
Mitsubishi Heavy Industries and Mitsubishi Electric Starmex are separate companies using completely different LED logic, wiring layouts, and control boards. Starmex flashes one green operation lamp, whereas MHI pairs green RUN and orange TIMER states. Sending the wrong brand name delays local parts checks.
What does it mean if my MHI RUN light flashes continuously while TIMER blinks?
Continuous rapid RUN flashing paired with counted TIMER bursts on residential MHI SRK systems maps to outdoor sensor errors, such as outdoor ambient, outdoor coil, or discharge pipe thermistors. Keep the indoor head switched off via remote and send a video clip for metered verification.
Can washing my MHI filters stop a 7-blink RUN and solid TIMER lockout?
Rinsing mesh dust screens cannot resolve a 7-blink RUN lockout because that code flags low refrigerant pressure, a closed service valve, or an indoor heat exchanger sensor defect. Continuing to run the unit low on gas risks overheating the outdoor compressor rather than restoring cooling.
Should I repair or replace an older MHI unit showing rotor lock or PCB blinks?
Sensors and indoor fan faults on MHI units under 8 years old are usually practical to repair once verified on site. For an outdoor board or E60 compressor rotor lock past 8 to 10 years, technicians confirm MHI parts lead time and cost first so you can weigh repair against replacement.

Sources