On this page
Quick summary
On MHI wall units without a display, the RUN lamp counts first and the TIMER lamp second, and the pair maps to an E-code. Count two full cycles. MHI is a separate company from Mitsubishi Electric with its own code table, so read the brand on the sticker first.
MHI light behaviour by unit type
MHI's Singapore residential range covers the Rocket, Deluxe and Exclusive families. Wall-mounted SRK units carry RUN and TIMER lamps, and some add a power lamp. Newer models have a display, while older units rely on the lamp pattern alone.
Lamp position and colour vary by model, and some units use symbols instead of RUN and TIMER labels. Match the pattern to your own unit before counting.
| Unit type | Indicators | Fault display |
|---|---|---|
| Wall-mounted SRK with display | RUN, TIMER and power lamps | E-prefix code on the panel or remote |
| Wall-mounted SRK without display | RUN and TIMER lamps | Counted RUN and TIMER flash pattern |
| Multi-split SRK fan coils | RUN and TIMER lamps per head | Pattern or code on the affected head |
Normal MHI light behaviour versus a fault
A steady RUN light is normal running. A slow RUN blink is standby, waiting for a command. A short wait before the compressor starts is protection logic. Inverter models pulse the RUN light during compressor ramp-up and the pulse settles once the room reaches the set temperature. None of these needs a service call.
| Pattern | Meaning |
|---|---|
| Steady RUN light | Running normally |
| Slow RUN blink | Standby, waiting for a command |
| RUN light pulsing at ramp-up | Compressor easing up to setpoint |
| Short wait before airflow | Compressor protection delay |
Fault patterns and the error codes they map to
On units without a display, the RUN light counts first and the TIMER light second. The pair maps to a row in the handbook table, and every row also appears in the Mitsubishi Heavy Industries error code list. Watch two full cycles before deciding, noting a lamp that stays on or off.
Outdoor rows include E40 for a closed gas-side service valve, E36 for compressor overheat and E59 for outdoor unit trouble. The same E-code can carry different board detail across MHI platforms. E14 depends on the platform, so note which unit reported it.
| RUN and TIMER pattern | Code | Fault row |
|---|---|---|
| RUN 1x, TIMER on | E6 | Indoor heat exchanger sensor 1 |
| RUN 2x, TIMER on | E7 | Room temperature sensor |
| RUN 4x, TIMER on | E9 | Drain abnormal |
| RUN 6x, TIMER on | E16 | Indoor fan motor |
| RUN on, TIMER 2x | E59 | Outdoor unit trouble |
| RUN keeps flashing, TIMER 5x | E53 | Suction pipe sensor |
| RUN on, TIMER 5x | E36 | Compressor overheat |
| RUN on, TIMER 6x | E5 | Signal transmission |
| RUN 2x, TIMER 2x | E1 | Wired remote controller wiring |
How to retrieve the stored error code
On units with a display, the panel or wired remote shows the E-code directly. Units with a wireless remote can also run self-diagnosis from the handset, and the manual for the exact model lists the button sequence.
Without a display, the RUN and TIMER pattern is the code. With several indoor heads, read the pattern from each head separately. A short video of both lamps on a lamp-only model keeps the count.
Blinking lights on MHI multi-split systems
MHI multi-splits pair several SRK indoor heads with one SCM outdoor unit. Each head reports its own pattern, so the number of heads affected is the first clue.
| What you see | Likely location | First step |
|---|---|---|
| One head blinks, others run | That head or its connection | Record the pattern from the affected head |
| Every head blinks together | Outdoor unit or shared wiring | Compare the pattern across heads |
| Heads blink different patterns | Separate indoor faults | List each pattern for the technician |
Shared versus local faults
The same pattern on every head points to the shared outdoor unit and wiring. A head that differs from the rest usually has the fault at that unit or its connection.