Quick summary
Clear 1.5 metres below each wall mount and trunking line the night before. Drape plastic sheets over beds and wardrobes to block cement dust. Confirm HDB permits, 20A isolator power, floor-trap access, and stay home to approve routes before drilling.
Clearing 1.5 Metres of Floor Space and Shielding Furniture
Aircon crews open tall A-frame ladders along bedroom walls and feed stiff copper lengths through beams and corners. Leaving beds, study desks, or bookcases pushed tight against the mounting wall slows work and risks scratched laminate.
Pull furniture at least 1.5 metres away from every indoor unit zone and trunking run the night before. Clear a straight walkway from the main gate to the service yard or aircon ledge so heavy condensers move cleanly without bumping door frames.
Core-drilling concrete HDB walls sends fine grey masonry powder drifting across rooms. Tape lightweight plastic drop sheets over mattresses, built-in wardrobes, curtains, and televisions so post-work cleanup stays simple.
Day-Before Readiness Checks Across HDB and Condo Rooms
Missing one small utility check often triggers a wasted second trip and extra labour charges. Walk every zone in your flat against this readiness table:
Scroll to see more columns
| Room or utility zone | Preparation target | Why installers need it | Delay if skipped |
|---|---|---|---|
| Wall mount and trunking path | 1.5m clear floor depth along walls | Safe ladder footing and straight pipe routing | Crew pauses while furniture gets shifted |
| Beds, wardrobes, and flooring | Plastic dust covers and floor cardboard | Catches masonry drilling grit and pipe debris | Fine cement dust coats bedding and hinges |
| DB box and 20A isolator | Confirmed live 15A or 20A aircon circuit | Safe final power hookup and run testing | Commissioning stalls until an EMA electrician attends |
| Toilet or service yard floor trap | Unobstructed wall access to drain point | Allows proper downward PVC condensate slope | Drain cannot terminate cleanly without backfall |
| HDB permit or condo MCST | Approved papers and lift padding booked | Mandatory estate compliance before noisy works | Security blocks crew entry on install morning |
Verifying the 20A Isolator Switch and Floor Trap Route
Most BTO flats come pre-wired with a dedicated 15A or 20A aircon power point beside the aircon ledge or service yard. Resale HDB flats sometimes hide aged switches behind cabinets or carry undersized legacy wiring for modern System 4 loads.
Find your DB box and check the aircon breaker label the night before. Need a new 20A isolator? Hire an EMA-licensed worker early so power is live for testing.
Open the bathroom and service yard doors to confirm nothing blocks the floor trap where the white PVC condensate pipe will discharge. Keep laundry racks, washing machines, and storage boxes pulled back temporarily.
What to Verify on Site Before Masonry Drilling Starts
Never leave installation day solely to a helper or empty flat unless you have already signed off exact positions during a pre-install site survey. Once a core drill punches through an HDB beam or wall, shifting trunking leaves permanent patch marks.
Keep a decision-making adult on site for the morning walkthrough and check four points:
- Stand in each bedroom and confirm exact indoor blower height, wardrobe door swing clearance, and curtain pelmet spacing.
- Trace the chalk-marked trunking path from every room to the condenser ledge and bathroom floor trap before the first drill bit turns.
- Inspect the delivered copper coil (SWG 22), 1/2-inch closed-cell insulation, and exact indoor-outdoor model labels on the cartons.
- If layout clashes look tricky, book a S$30 pre-install site survey beforehand (waived on installation) so routes and permits are locked early.