Quick summary
Every Singapore wall aircon carries a white rating sticker on its underside edge or inside the hinged front cover. Photographing the full indoor model string, trailing suffix, and serial code lets technicians match exact error tables, thermistors, and PCBs before visit one.
How to Locate and Photograph Your Indoor Sticker Safely
Switch the indoor unit off via your wireless remote before touching the casing so the horizontal swing flap closes cleanly. Stand squarely on the floor or a low, flat-footed step stool if the unit sits high above a doorway.
Never remove screws or pull trunking covers loose just to peek behind pipes. Every major Singapore residential brand places the rating sticker where owners can inspect it with bare hands.
- Check the smooth bottom face or lower-right side flank of the casing first using your phone torchlight.
- If nothing shows outside, grip both side notches of the hinged front cover and swing it upward until it clicks open.
- Look along the right-hand chassis rail near the filter frame for the barcode sticker showing Model No., Serial No., and refrigerant (R32 or R410A).
- Snap one sharp, glare-free close-up capturing every trailing letter and digit, then close both sides of the front cover firmly.
Brand-by-Brand Sticker Locations and Self-Check Table
Prefix letters tell technicians immediately whether you photographed the indoor fan coil or the outdoor condenser, and separate brands with similar names. Use the quick reference below to verify you grabbed the right code.
Scroll to see more columns
| Brand and indoor prefix | Typical indoor sticker spot | Pass or fail photo check | Safe fallback if unreadable |
|---|---|---|---|
| Daikin (CTKM, CTKC, CTKP, CTKS, FTKM) | Bottom-right underside edge or right flank inside hinged front panel | Pass when full trailing suffix (e.g. ZVMG) reads clearly | Check original tax invoice or NEA 5-tick label paperwork |
| Mitsubishi Electric Starmex (MSXY, MSY) | Bottom edge or bottom-right frame behind the hinged front cover | Pass when MSXY/MSY indoor code is distinct from outdoor MXY | Check each bedroom head separately; capacities vary per room |
| Mitsubishi Heavy Industries (SRK) | Bottom-right corner behind front panel (behind grille on cassettes) | Pass when SRK prefix confirms MHI rather than Starmex | Use purchase receipt or warranty slip instead of guessing brand |
| Panasonic (CS- indoor; CU- outdoor) | Bottom-right frame inside hinged front cover | Pass when full CS- string plus suffix appears in frame | Avoid prying stuck louvers; snap the installer invoice copy |
| Toshiba (RAS-), Midea, LG, Samsung, Sharp (AH-) | Right-hand interior wall beside filter slot under hinged cover | Fail if sticker is faded, painted over, or blocked by trunking | Stop prying Wind-Free or Frost Wash panels; send invoice or Form AC-02 |
Singapore EMA, HDB, and MOM Safety Stop-Line
Never unscrew indoor terminal covers just to read hidden board stamps. EMA rules keep live 230V wiring boxes closed to anyone without proper electrical training.
Never step onto window sills or HDB ledges to snap the outdoor unit plate. HDB and MOM height rules bar unsafe ledge access. A trained crew can check the outdoor unit safely if your invoice is lost.
Using Your Model Code to Book Repair or Servicing
One crisp plate photo stops wrong-part trips, since HDB living rooms often carry 18,000 BTU coils beside 9,000 BTU bedrooms. When a unit blinks, trips, or stops cooling, Snowflake Aircon Services tests faults on site for S$30, waiving that fee once repair proceeds. For routine care on working sets, standard servicing runs S$50 for a lone unit, S$60 total for two units, and S$25 per head once three or more rooms book together. Chemical washes run S$80 for one, S$70 per unit for two, and S$60 for three-plus flats. Strip-down overhauls cost S$150, S$125 per unit, or S$115 per unit.
Pair your sticker photo with these three helpful notes:
- Label which room each photo belongs to, such as master bedroom versus living hall.
- Include the refrigerant line printed on the sticker (R32 or R410A) if the text sits near a corner.
- Attach any original installation invoice or BCA Form AC-02 if you also need the outdoor condenser model confirmed.
- Note if the casing hides behind a condo false-ceiling slot so crews bring appropriate ladder clearance.