Mitsubishi Electric or Panasonic for a 4-Room HDB System 4

A 4-room HDB flat has three bedrooms and a living area, so a System 4 quote means one outdoor unit for all four. Between these two brands, that outdoor unit decides more than the badge.

On this page

Mitsubishi Electric or Panasonic for a 4-room HDB System 4?

Choose Mitsubishi Electric if efficiency decides it: its MXY-4H outdoor units beat Panasonic's CU-4XU units on weighted COP at both sizes. Choose Panasonic when its quote covers the same rooms and work for less.

The figures come from the NEA register as downloaded on 17 September 2026. All five units carry 5 ticks, so ticks do not separate them. Snowflake Aircon Services recommends Starmex unless a customer asks for another brand, because it has found the range reliable, easy to service and well supplied with parts.

Scroll to see more columns

Mitsubishi Electric or Panasonic for a 4-room HDB System 4? summary table
Outdoor unitCooling (kW)Weighted COPAnnual kWh (NEA basis)Registration expires
Mitsubishi Electric MXY-4H33VG26.885.952,57026 Dec 2028
Mitsubishi Electric MXY-4H33VG6.935.762,64627 Mar 2028
Panasonic CU-4XU33YBZ6.965.612,70410 May 2028
Mitsubishi Electric MXY-4H38VG8.056.192,9266 Mar 2028
Panasonic CU-4XU38YBZ7.935.783,00217 May 2028

Which size the flat needs: 6.9 kW or 8 kW

HDB lists a 4-room flat as three bedrooms, one of them a master, plus a living and dining area. That is four indoor heads on one outdoor unit.

Each brand registers two sizes, about 6.9 kW and about 8 kW. The right one depends on the four indoor sizes and how many rooms run together on a normal evening.

A quote built from the floor plan alone tends to land on the larger unit. The System 3 vs System 4 guide covers whether a fourth head is needed at all.

What the efficiency gap means in a year

The MXY-4H33VG2 is rated at 2,570 kWh a year against 2,704 kWh for the CU-4XU33YBZ. That is 134 kWh, about 5 percent, for nearly the same capacity.

The gap is real but modest. Compare it only after both quotes size the same rooms the same way.

What to check in each System 4 quote

A fair comparison needs the same four rooms and the same installation scope on both quotes. Ask for these lines in writing.

  • The exact outdoor model, the four indoor models, and that the maker approves the combination.
  • The capacity of each indoor head, room by room.
  • Piping, trunking, drainage, electrical work and removal of the old units.
  • Each brand's written warranty terms for the exact model, and the registration step.

Warranty terms to compare

Mitsubishi Electric's Singapore terms give 12 months general cover and 60 months on the compressor, with first-year labour. Ask the dealer for Panasonic's written terms for the same model.

The aircon warranty by brand guide sets the published terms side by side.

Common questions

Is Mitsubishi Electric or Panasonic more energy efficient for a System 4?
In the NEA register download dated 17 September 2026, Mitsubishi Electric's MXY-4H outdoor units have a higher weighted COP than Panasonic's CU-4XU units at both registered sizes, about 6.9 kW and about 8 kW. All of them carry 5 ticks on the NEA energy label.
What size System 4 does a 4-room HDB flat need?
Mitsubishi Electric and Panasonic both register System 4 outdoor units of about 6.9 kW and about 8 kW. For a 4-room HDB flat, the right size depends on the four indoor unit sizes and how many rooms run together, which a site check confirms.
Can I mix Mitsubishi Electric and Panasonic units on one System 4?
No. A System 4 uses one outdoor unit, and every indoor unit on it has to be the same brand. Each indoor model also has to be on that outdoor unit's approved combination list, so a Panasonic head cannot join a Mitsubishi Electric System 4.
Is a System 4 cheaper to run than four single splits?
Not necessarily. On the NEA register, the 5-tick System 4 outdoor units from both brands have weighted COPs between 5.61 and 6.19. Compare the annual kWh of the exact System 4 quoted against the single splits for the same rooms before deciding.

Sources