Mitsubishi Starmex MXY-5H48VG System 5 Sizing Guide

Mitsubishi Electric MXY-5H48VG provides 9.1 kW cooling across five circuits at 6.07 weighted COP and 3,399 kWh yearly under MELS-MIT-AC190019. Learn how executive flats, maisonettes, and landed homes plan zoning, pipe lengths, and isolators.

On this page

Quick summary

Mitsubishi Electric MXY-5H48VG holds NEA 5-tick approval MELS-MIT-AC190019 with 9.1 kW output, 6.07 weighted COP, and 3,399 kWh yearly use. One-chassis five-zone sets suit single-ledge executive flats and condos, while landed homes need careful pipe length and amp balancing.

Review MXY-5H48VG Output Figures and SP Household Billing

Approved on NEA MELS-MIT-AC190019 through 14 April 2028, Mitsubishi Electric MXY-5H48VG carries 5 ticks at 9.1 kW. Rated efficiency reaches 4.87 full load, 6.87 part load, and 6.07 weighted COP.

NEA records 3,399 kWh annually (S$918 label figure). Under Singapore's Q4 household price (31.16 cents per kWh after GST), that test benchmark hits S$1,059 yearly. Keeping two sleep rooms chilled overnight for 8h uses roughly S$53 to S$62 monthly.

Four to five active rooms across afternoons and nights land around S$125 to S$165 monthly. HDB executive flats and maisonettes claim S$400 Climate Vouchers, whereas landed houses and condos stay ineligible.

Compare MXY-5H48VG Specs Against Dual-Condenser Planning

Compare one MXY-5H48VG System 5 condenser against a System 3 plus System 2 split across ledge capacity and redundancy:

Scroll to see more columns

Compare MXY-5H48VG specs against dual-condenser planning summary table
Planning factorSingle MXY-5H48VG System 5Dual condenser (System 3 + 2)Site-survey verdict
NEA MELS registrationMELS-MIT-AC190019 (5 ticks)Two separate 5-tick condensers9.1 kW | 6.07 weighted COP on 5H48VG
Simultaneous 5-room load9.1 kW shared across 5 ports10.5 to 11.0 kW combined ceilingSplit setup holds higher midday reserve
Ledge space & redundancy1 outdoor chassis; 0 backup2 outdoor frames; split backupSingle-ledge flats need MXY-5H48VG
Power & pipe allowance1 high-amp isolator pointCheck HDB 30A/40A or landed 3-phaseStandard 50 ft/unit; long runs extra
Install & warranty termsQuoted after S$30 site survey22 SWG + 0.5-inch Armaflex Shield CX1yr work / 1yr parts / 5yr compressor

Balance Long Pipe Runs and Power Supply in Landed Homes

Multi-storey maisonettes and landed terraces stretch copper routes near or beyond our 50 ft per head baseline. Vertical risers need 22 SWG copper enclosed within half-inch Armaflex Shield CX foam sleeves, weighed R32 trim, and sloped Class 0 PVC drains per level.

Assign bedrooms to lower-draw ports so an 18,000 BTU lounge blower never starves upstairs zones. Confirm HDB 30A or 40A breaker caps on older executive flats early. Landed renovations should verify single-phase versus three-phase isolator capacity during site checks.

Decide When MXY-5H48VG Fits Your Layout and Service Budget

Pick MXY-5H48VG when a tight ledge holds just one outdoor unit. Choose a 3+2 split when two spaces allow full backup:

  • Start with a S$30 survey covering multi-floor risers and electrical breakers. Snowflake credits that exact fee toward your approved System 5 order or repair.
  • Five rooms enter our lowest S$25 per FCU general tier. Booking two FCUs runs S$30 per FCU, whereas one standalone FCU bills S$50 (14-day cover).
  • Chemical servicing removes thick slime across high-load zones. Groups of three-plus FCUs clean at S$60 per FCU, pairs clean at S$70 per FCU, and one standalone FCU runs S$80 with 60-day cover.
  • Stubborn blower fouling or recurring drips require chemical overhauls. Three-plus blowers cost S$115 per FCU, two cost S$125 per FCU, and one standalone blower runs S$150 with 90-day warranty.

Check Your Diagnostic or Servicing Price

Tap your job, unit count, and home type for our published Singapore rate — then send the pre-filled message on WhatsApp.

1. What do you need?
2. How many indoor units?
3. Property type & estate (optional)

Published Singapore estimate

$30 / visit site survey (waived on installation)

WhatsApp this estimate

Covers piping route check, condenser ledge access, and a firm nett package quote for your 3 indoor units.

1-year installation workmanship warranty + agent parts and 5-year compressor warranty.

Common Questions

Can an HDB Executive Apartment or Maisonette install Mitsubishi MXY-5H48VG?
Many HDB executive flats and maisonettes can install MXY-5H48VG when the concrete ledge fits the chassis and total draw stays within HDB's 30A or 40A limit. A BCA-trained installer should verify amps and exhaust clearance on site first.
Should a landed home choose one MXY-5H48VG or a System 3 plus System 2 split?
Landed houses with spacious outdoor yards gain higher peak cooling and fault redundancy by splitting five zones across System 3 plus System 2 condensers. Single-chassis MXY-5H48VG fits tight balconies or single-isolator zones.
What happens when landed or maisonette pipe runs exceed 50 feet per head?
Baseline installs include 50 ft runs using 22 SWG copper paired with half-inch Shield CX Armaflex for every FCU. Multi-storey landed drops exceeding 50 ft require extra pipe, insulation, and trimmed refrigerant charge priced after a S$30 site survey.
Do HDB MXY-5H48VG buyers get S$400 Climate Vouchers?
Citizen and permanent-resident HDB executive flat or maisonette owners claim S$400 vouchers for 5-tick MXY-5H48VG packages until end-2027. Landed houses and condos remain outside HDB voucher eligibility.