Mitsubishi Starmex MXY-3H28VG vs MXY-4H33VG Compared

Mitsubishi Electric MXY-3H28VG powers up to three indoor units at 6.56 kW (weighted COP 6.05), whereas MXY-4H33VG adds a fourth indoor port at 6.93 kW (weighted COP 5.76). Because MXY-4H33VG only adds 0.37 kW of outdoor output, four-room simultaneous cooling needs MXY-4H38VG instead.

On this page

Exact NEA register specs: MXY-3H28VG vs MXY-4H33VG

Both outdoor condensers sit at the core of Singapore's best-selling 5-tick R32 Mitsubishi Electric Starmex residential packages. Pulling exact figures from NEA's public air-conditioner directory (21 November 2026) highlights a subtle capacity detail many buyers miss when upgrading from System 3 to System 4.

Adding a fourth room port on MXY-4H33VG raises rated outdoor capacity by just 0.37 kW over MXY-3H28VG, making it tailored for alternating daytime living and nighttime bedroom schedules.

Exact NEA register specs: MXY-3H28VG vs MXY-4H33VG summary table
Specification (NEA 21 Nov 2026)MXY-3H28VG (System 3)MXY-4H33VG (System 4)
Maximum indoor unitsUp to 3 fan coilsUp to 4 fan coils
NEA ticks & refrigerant5 ticks | R325 ticks | R32
Rated cooling capacity6.56 kW (MXY-3H28VG2: 6.45 kW)6.93 kW (MXY-4H33VG2: 6.88 kW)
Full-load / weighted COP4.89 / 6.05 (VG2: 4.86 / 6.07)4.86 / 5.76 (VG2: 4.89 / 5.95)
NEA annual energy & cost estimate2,418 kWh | S$653/yr (VG2: S$645)2,646 kWh | S$714/yr (VG2: S$694)

When MXY-3H28VG is the smarter buy for 3-room and 4-room flats

If you live in a 3-room BTO flat (two bedrooms plus living hall) or a 4-room flat where you rely on a ceiling fan in the living room and cool only three bedrooms at night, MXY-3H28VG hits a sweet spot. Every connected head gets generous outdoor compressor headroom and a higher 6.05 weighted COP.

Avoid picking MXY-3H28VG expecting to splice a fourth indoor head onto it later; the outdoor manifold physically has only three piping ports.

Choosing between MXY-4H33VG and MXY-4H38VG for four rooms

MXY-4H33VG shines in typical 4-room HDB flats where the 18,000 BTU living-room unit runs during daytime weekends while the three 9,000 BTU bedrooms run after bedtime. Because rarely more than three heads run together, 6.93 kW handles alternating loads comfortably.

If your household regularly runs all three bedrooms and the living hall together on hot evenings, step up to MXY-4H38VG (8.05 kW, 6.19 weighted COP) so cooling stays brisk across every zone.

Common questions

What is the real difference between MXY-3H28VG and MXY-3H28VG2 on Singapore quotes?
MXY-3H28VG2 is an updated Singapore 5-tick revision of MXY-3H28VG listed on NEA's 21 November 2026 register. Rated output sits nearly identical at 6.45 kW versus 6.56 kW, while weighted COP edges up to 6.07 and annual label estimate trims slightly from S$653 to S$645.
Can MXY-4H33VG cool three bedrooms and an 18,000 BTU living room at the exact same time?
MXY-4H33VG delivers 6.93 kW total outdoor cooling, which covers alternating day living and night bedroom use cleanly. Turning all four indoor units on together on a warm Singapore evening splits that 6.93 kW across four rooms, noticeably slowing pull-down compared with MXY-4H38VG.
Is MXY-3H28VG more electricity efficient than MXY-4H33VG for a three-bedroom HDB flat?
On NEA's official efficiency figures, MXY-3H28VG posts a higher 6.05 weighted COP and lower S$653 annual label estimate than MXY-4H33VG (5.76 weighted COP, S$714). If you genuinely need only three indoor units, choosing MXY-3H28VG avoids paying for an unused fourth port.
Can I add a fourth indoor unit onto an MXY-3H28VG condenser in the future?
Adding a fourth indoor fan coil onto an MXY-3H28VG outdoor condenser is impossible because the outdoor manifold supports a strict maximum of three refrigerant ports. Homeowners who expect to air-condition a living hall or study room later should install a 4-port condenser upfront.