MXY-4H33VG vs MXY-4H38VG: Starmex System 4 Condensers

On NEA's register as of 21 November 2026, Mitsubishi Electric MXY-4H38VG delivers 8.05 kW at 6.19 weighted COP, against 6.93 kW and 5.76 weighted COP for MXY-4H33VG. Step up to MXY-4H38VG when running a large living room alongside bedrooms simultaneously.

On this page

MXY-4H33VG vs MXY-4H38VG: exact NEA register comparison

Both MXY-4H33VG (along with its updated MXY-4H33VG2 registration) and MXY-4H38VG are 5-tick R32 System 4 outdoor condensers for Mitsubishi Electric Starmex multi-splits in Singapore. Many HDB quotes default to the smaller 4H33VG to keep headline prices low without explaining the 16% capacity difference.

All figures below come straight from NEA's Registered Goods Product Search snapshot checked on 21 November 2026.

MXY-4H33VG vs MXY-4H38VG: exact NEA register comparison summary table
NEA specificationMXY-4H33VG (and 4H33VG2)MXY-4H38VG
NEA tick rating5 ticks (Multi Split)5 ticks (Multi Split)
Rated cooling capacity6.93 kW (VG2: 6.88 kW)8.05 kW (+16% higher capacity)
Full-load / weighted COP4.86 / 5.76 (VG2: 4.89 / 5.95)4.97 / 6.19 (higher efficiency ratio)
NEA label annual energy & cost2,646 kWh / S$714 (VG2: 2,570 kWh / S$694)2,926 kWh / S$790
Registration expiry on NEA27 Mar 2028 (VG2: 26 Dec 2028)6 Mar 2028

When MXY-4H33VG is plenty for a 4-room HDB flat

If your household runs two or three 9,000 BTU bedrooms overnight and switches the 18,000 BTU living-room unit on only during weekends when bedrooms are empty, 6.93 kW covers that staggered load comfortably.

Notice also that the newer MXY-4H33VG2 revision edges weighted COP up from 5.76 to 5.95 while trimming NEA label annual consumption to 2,570 kWh, making it an efficient match for standard 4-room HDB layouts.

When paying extra for MXY-4H38VG pays off

Step up to the 8.05 kW MXY-4H38VG whenever you fit a 24,000 BTU indoor unit in an open-concept living room, have west-facing afternoon sun across multiple rooms, or run three bedrooms plus the living area at the same time on weekends and holidays.

Despite delivering 1.12 kW more peak cooling, MXY-4H38VG actually posts a higher weighted COP (6.19 versus 5.76 on 4H33VG), meaning it handles part-load cruising efficiently without straining the compressor.

Check physical dimensions and electrical supply before ordering

Verify your HDB aircon ledge clearance and electrical circuit rating before upgrading to the larger 8.05 kW condenser, especially in older resale flats with 30A electrical loading. Always match exact indoor unit combinations against Mitsubishi Electric Singapore's published table.

Snowflake Aircon Services sizes MXY-4H33VG and MXY-4H38VG installations against real simultaneous room usage rather than pushing the cheaper 4H33VG onto heavy family loads.

Common questions

Is MXY-4H38VG worth the upgrade over MXY-4H33VG for a 4-room HDB flat?
Upgrading to MXY-4H38VG is worth the extra cost in a 4-room or 5-room HDB flat if you pair a 24,000 BTU living-room unit with three bedrooms or regularly run all four rooms together. Its 8.05 kW capacity prevents afternoon cooling slowdown.
Why does MXY-4H38VG show a higher NEA annual cost if its COP is higher?
NEA calculates label annual energy cost proportionally to rated cooling capacity under standardised test hours. Because MXY-4H38VG is rated at 8.05 kW versus 6.93 kW for MXY-4H33VG, its higher 6.19 weighted COP still reflects stronger efficiency per kilowatt of cooling delivered.
What is the difference between MXY-4H33VG and MXY-4H33VG2?
On NEA's register as of 21 November 2026, MXY-4H33VG2 is an updated 5-tick registration rated at 6.88 kW with a higher 5.95 weighted COP and lower 2,570 kWh annual estimate, compared with 6.93 kW, 5.76 weighted COP and 2,646 kWh for MXY-4H33VG.
Can MXY-4H33VG handle a 24,000 BTU living room unit plus three bedrooms?
Running a 24,000 BTU living-room head plus three 9,000 BTU bedrooms simultaneously pushes a 6.93 kW MXY-4H33VG well beyond its shared outdoor capacity. Homes with a 24,000 BTU living unit get noticeably stronger peak cooling from the 8.05 kW MXY-4H38VG condenser.