Refrigerant ODP Explained: The Test Every Gas Now Passes
The gas in a household aircon was replaced once before warming entered the argument. Ozone depletion potential decided that earlier round. Knowing what it graded, and what it has stopped deciding, keeps a green claim from doing work it cannot do.
By Team Snowflake | Updated 15 Sept 2026
What does ozone depletion potential measure?
The measure is a ratio built around one fixed point. CFC-11 was assigned the value 1, and every other substance is placed against it. UNEP describes the calculation as a steady-state ozone reduction per unit of mass released each year, taken relative to CFC-11.
Nobody handles the reference compound any more. CFC-11 was a foam agent and refrigerant that the Montreal Protocol removed from production decades ago. Its value stayed pinned at 1 regardless, because moving the anchor would break every figure already written into treaty annexes and national registers.
A score of zero says something narrow and precise. It says the substance carries none of the chemistry that attacks ozone. Whether the gas cools efficiently, whether it burns, and what it does to the atmosphere in any other respect are all questions answered somewhere else.
The Environmental Protection Agency in the United States publishes reference points across the range, and they show how uneven the scale is. Halons reach as high as 10. The whole hydrochlorofluorocarbon family sits below 0.2. Hydrofluorocarbons sit at zero, and the agency gives the reason in one clause: they contain no chlorine.
| Where a substance sits | What that band holds | What the position tells you |
|---|---|---|
| 1, by definition | CFC-11, the compound the whole scale is built on | The anchor. It was set by agreement, not derived from anything |
| Above 1 | Halons, which carry bromine in place of chlorine | Bromine attacks ozone harder per atom. EPA lists halons as high as 10 |
| Below 0.2 | The hydrochlorofluorocarbon family, as EPA groups it | A reduced score, and still a controlled substance |
| Zero | The hydrofluorocarbons, including the gas in current splits | No chlorine in the molecule, so there is nothing here to grade |
- Where a substance sits
- 1, by definition
- What that band holds
- CFC-11, the compound the whole scale is built on
- What the position tells you
- The anchor. It was set by agreement, not derived from anything
- Where a substance sits
- Above 1
- What that band holds
- Halons, which carry bromine in place of chlorine
- What the position tells you
- Bromine attacks ozone harder per atom. EPA lists halons as high as 10
- Where a substance sits
- Below 0.2
- What that band holds
- The hydrochlorofluorocarbon family, as EPA groups it
- What the position tells you
- A reduced score, and still a controlled substance
- Where a substance sits
- Zero
- What that band holds
- The hydrofluorocarbons, including the gas in current splits
- What the position tells you
- No chlorine in the molecule, so there is nothing here to grade
Why chlorine decided which compounds went on the list
The score follows one element through the atmosphere. EPA describes ozone depleting substances as compounds that release chlorine or bromine atoms once they break down high above the ground, and those loose atoms are what take ozone apart. How much of either element arrives up there, and how long it survives, is what a figure on this scale summarises.
Bromine does the same job harder, which is why the worst entries in the treaty are not cooling gases. Halons were built around bromine for fire suppression, and their scores sit above the reference compound. A refrigerant has never held the top of this scale.
Family names carry the answer before any table is opened. A chlorofluorocarbon holds chlorine and fluorine and little that helps it break apart early. Add hydrogen and the molecule becomes vulnerable in the lower atmosphere, so a smaller share of its chlorine survives the climb. EPA groups that whole hydrogen-bearing family below 0.2.
Take the chlorine out entirely and the score falls to zero. No engineering produced that result. It came from a change of composition, and it was finished across the industry well before most equipment now hanging on a wall was designed.
Treat ozone-friendly as a property of the chemistry when a brand attaches it to a product. Every manufacturer buying the same refrigerant inherits the same zero, at the same moment, without doing anything to earn it. A claim that cannot separate two boxes on a shop floor is decoration on a spec sheet.
How a measurement turned into a rule
The Montreal Protocol never counts raw kilograms. Article 3 sets out how a country's controlled level is worked out, and it instructs that annual production of each controlled substance be multiplied by the ozone depleting potential specified for it in the annexes. The ledger is therefore denominated in the measure itself.
Weighting the ledger set an exchange rate between substances. A low-scoring compound spent a small share of the allowance for the same tonnage, and anything above the anchor spent more than its weight. That arithmetic is how the hydrogen-bearing family got its opening, and EPA describes those compounds as transitional substitutes for the class above them.
The annexes are where a measure becomes a list. Each controlled substance appears in a group with its score attached, and that score travels with it into every national register built on the treaty. NEA runs the local register for the hydrochlorofluorocarbon family, licensing the companies that bring it across the border, and publishes a table of common HCFCs alongside their odp value.
How the tightening eventually reached one specific refrigerant is a longer story, and the r22 phase-out carries it. The part that belongs here is smaller. This measure never reached an owner. It reached production, it reached imports, and it reached the annex a substance was written into.
The rare environmental criterion with a finish line
WMO and UNEP publish a joint Scientific Assessment of Ozone Depletion every four years. The 2022 edition put the figure at close to 99 percent of the controlled substances phased out worldwide. Few rules of any kind can report a number like that.
The same assessment projects the layer returning to its 1980 values around 2040 for most of the world, around 2045 over the Arctic and around 2066 over the Antarctic, if current policies hold. Those dates explain why the ozone question has drifted out of sales conversations. The problem was worked through, and the argument moved to a different index.
What a production ban leaves behind
Stopping production leaves an inventory standing, and that inventory is why the recovery dates sit decades out. Compounds already manufactured carried on working inside equipment, inside foam and inside cylinders. Concentrations up there fall slowly because that stock drains slowly, and no factory has to be involved for a single kilogram of it to escape.
For a household the whole thing narrows to one moment of contact. A chlorine-bearing charge in an older machine only gets up there if the circuit is opened badly, and that happens on a repair day or a removal day. Every other day of that system's life is neutral on this measure, whatever the gas inside it scores.
Why every current refrigerant scores zero
The gases in household splits sold here are hydrofluorocarbons, and that family carries no chlorine. EPA puts it in a single sentence: these substances have zero ODP because they do not contain chlorine. R32 and R410A both belong to the family, so both score zero, and so does anything else assembled from the same chemistry.
On this scale the current generation is flat. Two models on the same shop floor score identically, and they would have scored identically the day either was launched. A figure that stopped varying has no power to separate them.
A second index took over the question, and it grades a different harm. Ozone depletion asks what a substance does to the layer overhead. Global warming potential asks what it does to the heat balance below, and the current generation is being reduced under that second measure through the hfc phase-down.
So a refrigerant can be genuinely harmless to ozone while sitting under active restriction. Both statements hold at once. A sales conversation that mentions only the first has told you about the settled half and stopped short of the live one.
Keep the energy instruments clear of all this. Minimum energy performance standards sit on the electricity side of the machine, and the energy label reports what a buyer is entitled to see. Neither one reads the refrigerant.
The designations turning up in newer equipment overseas, R290 and R454B among them, hold no chlorine either. Nothing in the next transition is being driven by this measure, and no future gas will be chosen because of it.
What a blend inherits
A mixture takes this property straight from its components. Where not one of them carries chlorine, the mixture scores zero, and there is no calculation left to check or dispute. Composition settles it.
That makes this measure easier to read than the warming index, where a blend gets a number of its own and somebody has to work it out before it can be trusted. On the ozone scale, a chlorine-free ingredient list is the whole answer.
What a zero on this scale is worth to a buyer
Read it as a settled constraint and move to what still varies. Every household split lawfully on sale here holds a chlorine-free gas, so an ozone line in a brochure describes a condition the whole shop floor met before opening. What differs between two compliant models shows up elsewhere: in what the label reports about electricity, in the sizing, and in the workmanship at the wall.
An older system is a different conversation, and it was never a legal one. The phase-out reached production and import. Equipment already fitted kept running, and the charge sealed inside was never something an owner had to hand over. What genuinely shifted for those systems is how easily a refill can be bought, and r22 refrigerant has its own page for that.
Push back if ozone is offered as a reason to replace a machine that still cools. The measure placed no duty on any owner, and it stopped distinguishing between products years ago. Anybody reaching for it now is reaching for a word with warm associations and no remaining content.
Ask which refrigerant the system holds, then confirm it yourself. One look at the aircon rating plate ends the guessing, and the charge weight is printed beside it. Everything about the gas on either index follows from that one short string of characters.
- Treat a zero on this scale as background. It stopped separating one product from another when the previous generation left production.
- Ask for the designation printed on the plate. A refrigerant name can be checked against a published table. An adjective cannot.
- Hold the two indices apart. One grades ozone damage and is closed out, the other grades warming and is still being tightened.
- Refuse the replacement pitch when ozone is the reason offered. That word has no bearing on a machine already hanging on a wall.
- Spend the attention on sizing and workmanship. Those still vary between two quotes. The ozone score does not.
| What you are told | What it settles | What to ask next |
|---|---|---|
| An ozone-friendly claim on the spec sheet | Nothing between two models. Every one of them qualifies | Which refrigerant by designation, and how many kilograms |
| Your old unit runs on an ozone-depleting gas | That it belongs to an earlier chemical family | What the actual fault is, before the gas takes the blame |
| Zero ODP and low warming impact, in one breath | Only the first half. The second half is still moving | Split the two claims apart and weigh them separately |
| Environmental rules mean the system has to go | Nothing at all. No rule here reaches an installed machine | Which instrument, and the date it commenced |
- What you are told
- An ozone-friendly claim on the spec sheet
- What it settles
- Nothing between two models. Every one of them qualifies
- What to ask next
- Which refrigerant by designation, and how many kilograms
- What you are told
- Your old unit runs on an ozone-depleting gas
- What it settles
- That it belongs to an earlier chemical family
- What to ask next
- What the actual fault is, before the gas takes the blame
- What you are told
- Zero ODP and low warming impact, in one breath
- What it settles
- Only the first half. The second half is still moving
- What to ask next
- Split the two claims apart and weigh them separately
- What you are told
- Environmental rules mean the system has to go
- What it settles
- Nothing at all. No rule here reaches an installed machine
- What to ask next
- Which instrument, and the date it commenced