Reinstalling an Aircon After a Move: Gas, Piping, Warranty

A relocated aircon only works as well as the way it was taken down. If the gas was pumped into the outdoor unit and the pipes are re-flared and vacuumed at the new place, it should cool as before.

On this page

What a relocated aircon needs

Before removal, the refrigerant is pumped back into the outdoor unit so none escapes. At the new place, the flares are remade, the piping is vacuumed and the charge is checked before the unit runs.

Mitsubishi Electric's installation manual sets out the same steps: pump down when relocating, remake flares, then vacuum before charging.

Relocation and the gas after reinstallation
JobOur rate
Relocate a unit within the same home$300–$450 / unit
Relocation to a new addressQuoted per job
Gas after a leak is found and sealed, R32$120–$200
Gas after a leak is found and sealed, R410A$80–$150

A relocation to a new address is quoted after a site check. If the charge is short after reinstallation, gas has leaked, and the leak is found and sealed before any gas is added.

Our rates are from our rate card.

Reinstallation checklist

Ask the relocation company which of these it does, in writing.

  • Refrigerant pumped back before the pipes were cut.
  • Units capped and moved upright, without knocks to the coils.
  • New piping where the old run cannot be reused at the new place.
  • Flares remade, not reused.
  • Piping vacuumed before the gas is released.
  • Charge checked; extra gas only for a pipe run longer than the manual's pre-charged length, never to cover a leak.
  • Every unit run and checked for cooling and drainage.

Why a moved aircon sometimes leaks

Most leaks after a move are at the joints. A flare reused instead of remade, or a joint not pressure checked, can lose gas within weeks.

If cooling fades soon after a move, ask the relocation company to check its joints before paying anyone for a top-up.

What a move does to the warranty

Warranty terms differ on moves. Daikin Singapore ends cover once a unit goes to another premises; MHI's terms list relocation as an exclusion; LG's exclude faults arising from dismantling or relocation.

Ask the relocation company which brand terms apply, and keep its invoice on file.

Common questions

Does a relocated aircon need a gas top-up?
Not always. If the gas was pumped down into the outdoor unit and the new run is within the pipe length the unit's manual pre-charges for, the existing charge is usually enough. A longer run needs gas added by weight. A short charge after a move means a leak, which has to be found and sealed first.
Can the old piping be reused when an aircon is relocated?
Usually not at a new address, where the route and lengths differ. New piping is laid to suit the new positions. Within the same home, a short reroute may reuse some piping, but the flares are always remade and the pipes vacuumed before any gas goes back in.
Why is my aircon not cold after being relocated?
An aircon that is not cold after relocation has usually lost gas at a joint, often a flare that was reused or not tightened properly, or was not charged correctly for a longer pipe run. Ask the relocation company to check its joints and the charge before paying for a separate top-up.
Who should take down an aircon that is still under warranty?
Read the brand's terms first. Daikin Singapore ends its warranty on relocation to another premises, MHI lists relocation as an exclusion, and LG rules out faults from dismantling or relocation. Where cover ends anyway, any trained technician can move the unit; where it does not, ask the brand who may.