Installation faults that appear during early humid nights
Biofilm jelly takes months to grow, so a spotless new fan coil leaking during week two points straight to gravity flow or vapour sealing. Even a two-millimetre tilt away from the drain outlet lets water pool at the wrong corner of the shallow internal tray until it spills down freshly painted plaster.
Equally frequent in renovated flats is a corrugated drain hose crushed between the rear unit chassis and the wall, or a PVC drain run clipped dead-flat inside trunking without downward fall. Whenever a carpenter later drives a screw or shifts false-ceiling framing, hidden drain joints can pull slightly loose.
| Where water appears | Most probable setup cause | Clean permanent fix |
|---|---|---|
| Left or right bottom corner of FCU | Wall mounting plate tilted slightly away from the drain spout | Re-level backplate with spirit level and pour-test tray runoff |
| Centre trickle down wall behind unit | Kinked rear drain tailpiece or loose rubber hose clamp | Lift chassis, unkink hose cleanly, and secure clamp tightly |
| Drips along PVC trunking seam | Split foam insulation gap letting humid air sweat on cold copper | Seal closed-cell insulation seams airtight with vapour-barrier tape |
| Delayed gurgling then sudden overflow | Flat or sagging drain pipe creating an air-locked water belly | Re-clip drain line to continuous downward gradient to floor trap |
Why renovation dust accelerates early drain blockages
Turning on a freshly mounted aircon while painters sand skim-coat plaster or tile cutters run in the next room pulls fine cement powder directly onto wet aluminium fins. Unlike fluffy bedroom lint, plaster dust sets into gritty grey mortar right inside the first elbow of a brand-new condensate pipe.
Keep new indoor units wrapped and powered off until wet carpentry and sanding wrap up completely. If plaster dust already entered the tray, prompt thorough flushing prevents hardened plugs from backing water onto bedroom walls.
Checking workmanship coverage before paying out of pocket
Most residential aircon installations in Singapore include a separate workmanship warranty covering pipe slope, mounting level, and insulation sealing alongside the manufacturer hardware warranty. Document exact drip locations with timestamped photos while the wall is still visibly damp.
If the installation warranty has lapsed or you need an independent diagnostic check after handover, verify first whether your hardware carries brand-specific rules such as PRISM+ official support for in-warranty hardware defects. Otherwise WhatsApp a photo of the damp wall; Snowflake Aircon Services handles spirit-level, pour-test, and insulation checks.