Why fresh leaks persist after clearing the drain pipe
Most residential water leaks stem from jelly-like biofilm choking the condensate hose, so homeowners reasonably expect a thorough flush to solve the mess. When droplets still trail down the painted wall or fall from the centre casing within hours, the collection pan itself is usually failing to hold chilled water.
Years of thermal contraction, harsh alkaline cleaners, or rough dismantling during past washes can open fine stress cracks along plastic tray spigots. On older ducted fan coil units in offices and shophouses, galvanic corrosion eats pinholes straight through galvanised steel trays.
| Drain pan condition | Leak pattern observed | Practical repair path |
|---|---|---|
| Hairline crack in plastic FCU tray | Steady dripping from one corner or middle housing seam | Replace OEM drain pan assembly if model parts remain stocked |
| Saturated rear tray foam insulation | Cold sweating along the wall directly behind the FCU | Dismantle FCU, dry chassis, and apply fresh closed-cell insulation |
| Rusted commercial metal pan | Brown rust stains spreading across false ceiling boards | Fabricate replacement stainless tray or swap aged fan coil unit |
Assessing plastic trays versus concealed rear drainage channels
Wall-mounted fan coil units actually rely on two catch surfaces: the visible front tray beneath the louvres and a moulded rear trough cast into the back chassis. If the rear channel splits behind the evaporator coil, silicone sealant applied blindly from the front rarely holds under constant cold moisture.
Replacing a removable front drain pan on current Daikin, Mitsubishi Electric, or Midea units is straightforward once stock availability is confirmed. Conversely, a split integrated rear chassis on an eight-year-old FCU often makes swapping the indoor unit or full system more sensible.
Preventing repeat ceiling damage in homes and shops
Temporary tape or quick epoxy patches tend to peel away once humid Singapore air condenses on cold plastic overnight. Before committing to another chemical overhaul, ask the technician to perform a controlled water-pour test with the front cover removed so you can watch where water escapes.
Commercial ceiling cassettes and concealed ducted systems benefit from periodic tray inspection during routine servicing before rust penetrates false ceilings. Clear photographic evidence of the cracked spigot or rusted seam helps owners decide confidently between a genuine tray swap and equipment replacement.
Common questions
Can silicone sealant permanently fix a cracked plastic aircon drain pan?
How do technicians tell a cracked drain pan apart from sweating insulation?
Are replacement drain pans available for every old aircon model in Singapore?