Do not keep resetting a breaker that trips repeatedly. It is isolating a real fault. Leave the circuit off and have the connections checked.
Likely Causes
- A terminal left under-tightened holds in calm conditions and fails under load.
- A protective cover left open lets moisture reach an exposed terminal.

Quick Fault Summary
| Likely cause | What to check | Typical next step |
|---|---|---|
| A terminal left under-tightened | The trips started only after the service or top-up visit. | A technician opens the terminals that were worked on, checks for tightness and heat damage, replaces anything discoloured and runs the unit under load to confirm it stays cool. |
| A protective cover left open | The trips follow humid weather rather than heavy use. | A technician dries and inspects the exposed terminal, closes and secures the cover, and checks for corrosion before the circuit returns to service. |
- Likely cause
- A terminal left under-tightened
- What to check
- The trips started only after the service or top-up visit.
- Typical next step
- A technician opens the terminals that were worked on, checks for tightness and heat damage, replaces anything discoloured and runs the unit under load to confirm it stays cool.
- Likely cause
- A protective cover left open
- What to check
- The trips follow humid weather rather than heavy use.
- Typical next step
- A technician dries and inspects the exposed terminal, closes and secures the cover, and checks for corrosion before the circuit returns to service.
1. A Terminal Left Under-Tightened
Trips that began after a visit and worsen when the unit works hard usually mean a terminal was not fully tightened. It holds in calm conditions, then heats under load until the breaker sees a fault.
How to Tell
Trips under heavy load in any weather point to the terminal. A cover left open trips on humid days, not on dry days however hard the unit works.
- The trips started only after the service or top-up visit.
- They happen when the unit works hardest, such as hot afternoons.
- A sharp or acrid smell lingers around the outdoor switch.
- The trips are becoming more frequent over time.
How We Confirm It
A technician opens the terminals that were worked on, checks for tightness and heat damage, replaces anything discoloured and runs the unit under load to confirm it stays cool.
Do not run the circuit if anything smells sharp or scorched at the switch. A terminal that has begun arcing worsens each time it is re-energised.
Related Cases
2. A Protective Cover Left Open
Trips that follow humid days on a recently serviced unit usually mean a protective cover was not fully closed. The gap lets moisture settle on an exposed terminal until it bridges and the breaker cuts the circuit.
How to Tell
Trips on humid days and none on dry days, however hard the unit works, point to the cover.
- The trips follow humid weather rather than heavy use.
- It behaves normally on dry days.
- A cover or panel near the terminals sits slightly open.
- Nothing was wrong before the service visit.
How We Confirm It
A technician dries and inspects the exposed terminal, closes and secures the cover, and checks for corrosion before the circuit returns to service.
Never touch or close a displaced cover around electrical connections yourself. Leave the circuit off and send a photo of the cover with your WhatsApp message.