A Fujitsu that has power but will not start, keeps restarting or shows a communication code may need a new board, or only a smaller fix to its wiring or controls. We test the supply, wiring, sensors and connected parts before quoting a replacement board.

Message us on WhatsApp

On-site check: $30 / visit. Visit fee waived if you proceed with the quoted work.

On this page

Signs Your Fujitsu Aircon Needs a PCB Check

  • The Unit Has Power but Will Not Start

    Lights or the controller may still respond while the indoor unit, outdoor unit or both refuse to run normally.
  • One Room or the Whole System Stops Responding

    The pattern across rooms helps separate an indoor-board problem from an outdoor or shared communication fault.
  • A Communication or Board-Related Error Appears

Service Scope

  • Find the cause

    We check power, wiring and sensors to isolate the fault. Depending on the model, we test the indoor and outdoor boards or inverter drive.

  • Confirm the repair and quote

    We quote the repair and confirm parts and lead time before you approve. If the board has failed, we replace it with one of the same revision and test startup, controls and communication after fitting.

Workmanship Warranty

Labour

30-day workmanship warranty. If the same fault returns from our repair, we come back and the labour is on us, with no second on-site check fee.

Parts

Parts carry the distributor's warranty for that component, so the term varies by part. We tell you both terms before you approve the work.

Photos from Recent Jobs

What Customers Say

  • “Great people and process. Booked their $30 check when my air conditioner could not switch on. They traced the problem to wiring. No upsell, no drama. Repair done same day, check fee waived. Everything upfront, no hidden cost. Definitely would use their services again! 5/5”
    Yong Jun YeoGoogle
  • “The installer for my new aircon had done a brillant job and the communication had been seamless as well. I am happy in engaging their service!😄”
    cz0903Carousell
  • “Repeated the chemical wash today. Their professional team made sure there was minimal mess and dirt during the process. Can really feel the difference, the aircon feels much better after the servicing. Very satisfied with their service!”
    jonathan limGoogle
  • “they are amazingly on time, and very upfront on the prices. Friendly disposition and they provided valuable advices. i like how that they only sell what you need. Just awesome!”
    makchique_specsCarousell
  • “Customer service was prompt and responsive throughout. Guys came on time, helped to advise on the proper cleaning and relocation, even helped me to save money. Highly recommended!”
    A NGoogle
  • “The guys at Snowflake go above & beyond in terms of customer service. I had contacted them due to my aircon unit leaking. The guys spent an hour doing chemical clean. However my unit starting leaking again that night. Snowflake were extremely proactive by sending same guys next guy to fix the problem. They located pipe outside & cleared it. Really highly recommend 👍🏼🤩”
    nazzasgCarousell
  • “For our 1 year contract, we are satisfied with the efficiency and skilled of the technicians who maintained our aircon. Easy to schedule and coordinate. Hence, we will re contract for another year. Thanks for your service.”
    Marian ArcaoGoogle
  • “Fast and efficient service! 100% satisfied with the fast work! Arrived on time and work done was very professional for our commercial unit! Even provide us with new controller (at a price) cause ours didnt work anymore! 😔”
    baecaresgCarousell
  • “Used them a few times, very pleased with service level and prices. They provide honest advice on what is needed or not. Plus, they always bring a tarp to cover surfaces. No dodgy upselling practices. Recommended. Will continue to engage their service.”
    HW LGoogle
  • “Angeline is very patient in answering all my queries via chat. Tony came to check and does the necessary and give really good recommendation and advices on what is really needed to be done. Recommended 👍”
    lill.yCarousell
  • “Excellent Experience Installing System 3 Air Conditioner Knowledgeable, flexible, and efficient service.”
    David NgGoogle
  • “Excellent service, able to solve our problem with the aircon removal professionally and goes the extra mile to help us! Would recommend 101%! 💯💯”
    kullookCarousell
  • “Mr Yi Tat & Mr Kian were very efficient at servicing 4 ACs within 2 hours! They were very friendly and extremely easy to communicate with throughout the process. Will definitely call them back for future servicing. Thank you, gentlemen!”
    Murshidah MunibGoogle
  • “Engaged them because of good reviews and truly they deserved the good reviews. Tony and Ian were able to rectify my problems (other technician was not able to pin point the fault). Repaired and service with resonable charges. Thanks Tony and Ian for solving my issue. 🙏”
    ngeokhimCarousell
  • “My go to Aircon servicing for years on. Always prompt in responses and punctual on day if servicing. If delays are expected, they will update via WhatsApp. Never upsell and is honest and dependable. I always have Yen for my servicing. great guy!”
    Joanne CGoogle
  • “Technician came within the time frame that they provided and the technician even go extra miles in cleaning and wiping the surrounding areas after chemical wash. Servicing is indeed good”
    SharonnczyCarousell
  • “The technician explained their solution thoroughly and their price is transparent. Recommended”
    Zi Hao TanGoogle
  • “trusted,easy&fast reply..e service was excellent..e servicing man advice abt my aircon..no messy dust..👍 now my 3 unit aircon getting much colder...tqsm..(will deal wif u again)❤”
    idaomrsleeCarousell
  • “Great service! The response was very fast and they arranged the repair quickly. The technician was experienced and knew exactly what to do. Everything was fixed efficiently and the pricing was very reasonable. Definitely value for money—highly recommended!”
    Alex LuGoogle
  • “Thumbs up for snowflake aircon service. Delayed a bit on the arrival but they are able to inform prehand. Their guys are very professional to recommend what's the best solution for me. Reasonable price with quality work. Will surely engage them again :)”
    ivanaviCarousell
  • “My family has been going back to them for 10 years+. Service is always amazing and the people are very friendly 🤗🤗”
    naurahGoogle
  • “Prompt arrival and professional service. Been engaging them for 3 years now. Highly recommend! 👍”
    luckyzackyCarousell
Checks, models and error codes

Is Fujitsu PCB Repair Worth It?

Replacing the PCB is usually sensible when the rest of the system is healthy, the exact board revision is available and testing has ruled out wiring, sensors and connected loads.

Fujitsu repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsRepair.
5-8 yearsRepair most faults.
8-12 yearsPCB and fan motor failures become likely, and parts take longer.
Over 12 yearsReplace after a major component failure, especially if the unit has had several repairs.

Reasons for each row: full Fujitsu table.

You can wait

Testing finds a loose connector or a bad sensor. Fix that and keep the board.

Do not wait

The compressor fails to start on most attempts. A failing board does not recover, and an intermittent fault becomes permanent.

On-site check $30 / visit, waived if you go ahead with the quoted repair. Rates as of 20 Nov 2026. See our aircon system replacement process.

  • Power or Wiring Fault

    Loose terminals, a damaged interconnect or unstable supply can produce board and communication errors.
  • Sensor or Connected Load

    A shorted thermistor, motor or valve can pull down a healthy board or make its input look incorrect.
  • Inverter Power Stage

    On inverter systems, the main control PCB and the IPM or driver circuit are tested as separate failure points.

What Is Different on Fujitsu Systems

A single Fujitsu indoor unit faulting while the other rooms continue normally usually keeps the investigation on that unit's board, sensor or wiring rather than the shared outdoor unit.

Examples of Fujitsu Systems We Check

  • ASAG / ASYG Residential Wall-Mounted Systems

  • AOTG / AOYG Multi-Split Outdoor Systems

  • AUXG Ceiling Cassette Systems, Subject to Panel and Access Checks

Model not listed

Message us the error code or what the unit is doing. A photo or short video helps if you have one.

Parts and timing

Common Fujitsu parts remain available, but older outdoor boards and fan motors can take longer to source than equivalent Daikin or Mitsubishi Electric parts.

Choose where the code appeared on your unit.

Indoor unit or controller57 guides
Outdoor unit10 guides
Whole-system faults3 guides

Every code is in the full lookup for this brand. Last reviewed 2026-08-21.

Other Fujitsu Repair Checks

Find the service that matches a different fault on the same brand of aircon.

Frequently Asked Questions

How do you confirm a Fujitsu PCB fault?
To confirm a Fujitsu PCB fault, we identify the exact indoor and outdoor models, check the displayed code, test the power supply and communication wiring, then separate sensor, connected-load, indoor-board, outdoor-board and inverter-stage faults. The part is quoted, with its lead time, only after those tests.
Is a Fujitsu error code enough to order the PCB?
A Fujitsu error code alone is not enough to order the PCB. We match the code to the exact Fujitsu model and test the reported PCB circuit or protection on site. The PCB is ordered only when that testing confirms it, so a cheaper fault is not missed.
Should I repair or replace my Fujitsu aircon?
Replacing a Fujitsu PCB is usually worth it when the rest of the system is healthy and the exact board revision is available. Fujitsu systems commonly last 10-14 years. For a Fujitsu system over 12 years, replace after a major component failure, especially if the unit has had several repairs.