- 5.0Google & Carousell
- 15,000+jobs completed
Daikin VRV 5 Heat Recovery Aircon UJ-37 Error Code
Confirm the listed meaning of Daikin VRV 5 Heat Recovery UJ-37, note the unit that shows the code and its model, and match the service manual before diagnosis. Match the model first; same-looking codes can point to different rows.
What does Daikin UJ-37 mean?
Daikin VRV 5 Heat Recovery UJ-37 is listed as airflow rate below the legal limit for EKEA or EKVDX, the paired VAM reported A6-28 for the R32 application, and supply airflow rate below the legal safety limit in the VRV 5 Heat Recovery REMA / REYA R32, VRV 5 Heat Pump RYMA / RXYA R32, EKVDX / VAM R32 ventilation, and EKEA / EKEXVA AHU control box fault lists. This meaning comes from the manufacturer's own diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
What to do now
Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.
Record UJ-37 and match the service manual
Record UJ-37 and stop there; the manufacturer gives no customer reset procedure. Arrange diagnosis with the matching service manual.
No manufacturer reset steps listed for UJ-37
Capture the complete UJ-37 error code and model stickers first. The manufacturer lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
UJ-37 error code, a clear display photo, Daikin VRV 5 Heat Recovery indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared
Choose the listing that matches your unit
The same code has more than one listed meaning. Match the model family, the system type and the unit that shows the code before approving parts.
| Code | What it means | What to check first |
|---|---|---|
| VRV 5 Heat Recovery R32 - UJ-37 / VRV 5 Heat Pump R32 - UJ-37 | Airflow rate below the legal limit for EKEA or EKVDX | Record the displayed code, which unit shows it, and the serial number for qualified diagnosis. |
| EKVDX / VAM R32 ventilation - UJ-37 | The paired VAM reported A6-28 for the R32 application | Match the EKVDX and paired VAM model, then use the project service manual for diagnosis. |
| EKEA / EKEXVA AHU control box | Supply airflow rate below the legal safety limit | Match this meaning to your installed model and the unit that shows the code, then use the checks below. |
- Code
- VRV 5 Heat Recovery R32 - UJ-37 / VRV 5 Heat Pump R32 - UJ-37
- What it means
- Airflow rate below the legal limit for EKEA or EKVDX
- What to check first
- Record the displayed code, which unit shows it, and the serial number for qualified diagnosis.
- Code
- EKVDX / VAM R32 ventilation - UJ-37
- What it means
- The paired VAM reported A6-28 for the R32 application
- What to check first
- Match the EKVDX and paired VAM model, then use the project service manual for diagnosis.
- Code
- EKEA / EKEXVA AHU control box
- What it means
- Supply airflow rate below the legal safety limit
- What to check first
- Match this meaning to your installed model and the unit that shows the code, then use the checks below.
Guidance for your model
Notes that match the code to your exact model. Electrical, refrigerant, wiring, resistance and component checks are for a technician.
| Detail | What it says |
|---|---|
| Singapore / model note | Official Daikin 4P687640-1D row for the REMA5A7Y1B and REYA8~20A7Y1B VRV 5 Heat Recovery R32 family. Confirm the exact model and displayed punctuation before using this interpretation. |
| Singapore / model note | Official Daikin 4P749918-1B row for the RYMA5A7Y1B and RXYA8~20A7Y1B VRV 5 Heat Pump R32 family. Confirm the exact model and displayed punctuation before using this interpretation. |
| Singapore / model note | Daikin Singapore lists heat-reclaim ventilation and DX-coil air-treatment applications, but exact EKVDX suffix availability is not claimed. Apply this row only to a matching EKVDX32~100A2VEB and paired VAM system. |
- Detail
- Singapore / model note
- What it says
- Official Daikin 4P687640-1D row for the REMA5A7Y1B and REYA8~20A7Y1B VRV 5 Heat Recovery R32 family. Confirm the exact model and displayed punctuation before using this interpretation.
- Detail
- Singapore / model note
- What it says
- Official Daikin 4P749918-1B row for the RYMA5A7Y1B and RXYA8~20A7Y1B VRV 5 Heat Pump R32 family. Confirm the exact model and displayed punctuation before using this interpretation.
- Detail
- Singapore / model note
- What it says
- Daikin Singapore lists heat-reclaim ventilation and DX-coil air-treatment applications, but exact EKVDX suffix availability is not claimed. Apply this row only to a matching EKVDX32~100A2VEB and paired VAM system.
What to check before repair
The manufacturer's fault table gives the code's meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.
| You can check | Technician should confirm |
|---|---|
| Photograph the complete UJ-37 error code before taking any action. | Confirm UJ-37 exactly and record which controller, gateway, or unit reported it. |
| Capture the Daikin VRV 5 Heat Recovery indoor and outdoor model stickers and identify which controller or unit reported it. | Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope. |
| The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action. | Follow the matching service-manual procedure and keep measured test evidence before naming a failed part. |
- You can check
- Photograph the complete UJ-37 error code before taking any action.
- Technician should confirm
- Confirm UJ-37 exactly and record which controller, gateway, or unit reported it.
- You can check
- Capture the Daikin VRV 5 Heat Recovery indoor and outdoor model stickers and identify which controller or unit reported it.
- Technician should confirm
- Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope.
- You can check
- The manufacturer provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action.
- Technician should confirm
- Follow the matching service-manual procedure and keep measured test evidence before naming a failed part.
Source-bounded repair decision
Daikin VRV 5 Heat Recovery UJ-37 confirms the fault label the manufacturer lists, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
Whether the reporting controller or unit and exact installed model are confirmed.
What the matching service-manual procedure and measured tests show.
Whether the proposed repair names the evidence for the failed part or condition.
Daikin UJ-37 questions
What does the Daikin UJ-37 error mean?
Can I fix a Daikin UJ-37 error myself?
Is it safe to keep running the aircon with a UJ-37 error?
What causes a Daikin UJ-37 error?
Will a Daikin UJ-37 error need a repair or a full replacement?
What should I send a technician about a Daikin UJ-37 error?
Where to go next
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Daikin list or check a few codes in the same fault category.
Read next
Use this quote-check guide only after the matching service manual identifies the diagnostic path.