Gree Aircon LP Error Code
Gree LP means DC bus-bar low-voltage protection on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. If this meaning of LP matches your model, do not reset it.
- What it means
- DC bus-bar low-voltage protection on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. Other Gree models list a different meaning for LP; match the model first.
- Is it serious?
- Yes. Gree LP is a high-severity electrical fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- If this meaning of LP matches your model, do not reset it. Note the code and arrange a diagnosis. Do not follow the steps for a different model. Any homeowner step for LP depends on which model you have.
- Is it worth repairing?
- Whether Gree LP is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the power supply or an electrical circuit. If the cause is a failed board, it is replaced, not repaired; a wiring or supply fault is a smaller repair. The code names the fault, not the failed part, so measure before you decide on LP.Gree by age, from our Gree page:
Gree repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair sensor, fan and minor electrical faults. Over 8 years A compressor or inverter fault on a budget-tier system can reach replacement cost. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing Gree LP before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page. On a Gree VRF system, we service but do not repair, so that fault goes to Gree's authorised agent.
What Does Gree LP Mean?
Gree LP means DC bus-bar low-voltage protection on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. Other Gree models list a different meaning for LP; match the model first.
What Causes Gree LP?
Gree's fault list for Multi GEN2 wall mount gives the meaning of Gree LP but not its causes. A technician finds the cause by measurement against the service manual for the installed model.
Which Gree LP Meaning Matches Your Unit?
Gree LP has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means |
|---|---|
| U-Match duct type | Models of indoor unit and outdoor unit do not match |
| Multi GEN2 wall mount | DC bus-bar low-voltage protection |
| Ultra Heat GMV6 Mini VRF (2024) | Zero-crossing malfunction of PG motor |
- Model / series
- U-Match duct type
- What it means
- Models of indoor unit and outdoor unit do not match
- Model / series
- Multi GEN2 wall mount
- What it means
- DC bus-bar low-voltage protection
- Model / series
- Ultra Heat GMV6 Mini VRF (2024)
- What it means
- Zero-crossing malfunction of PG motor
Show 2 more meanings
| Model / series | What it means |
|---|---|
| Multi ECO R32 multi-zone | Indoor and outdoor unit capacity mismatch |
| All Match floor / ceiling R32 | Indoor/outdoor unit capacity mismatch |
- Model / series
- Multi ECO R32 multi-zone
- What it means
- Indoor and outdoor unit capacity mismatch
- Model / series
- All Match floor / ceiling R32
- What it means
- Indoor/outdoor unit capacity mismatch
What Does a Technician Check for Gree LP?
Before quoting parts for Gree LP, a technician should match LP to your exact model before choosing what to test.
Follow that model's service procedure for LP and quote parts only on measured evidence.
Do not apply a sensor, drain, valve, fan, compressor, electrical, or reset procedure meant for a different model.
| Detail | What it says |
|---|---|
| Diagnostic note | Confirm the indoor and outdoor model pairing before assuming a board fault. |
- Detail
- Diagnostic note
- What it says
- Confirm the indoor and outdoor model pairing before assuming a board fault.
Will Gree LP Need a Repair or a New Unit?
Gree LP names a different fault on different models, not a failed part. Approve parts only once tests on your model show the cause of LP; compare repair cost with system age only after that.