Gree Aircon LC Error Code
Gree LC means compressor start failure on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. If this meaning of LC matches your model, do not reset it.
- What it means
- Compressor start failure on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. Other Gree models list a different meaning for LC; match the model first.
- Is it serious?
- Yes. Gree LC is a high-severity compressor fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- If this meaning of LC matches your model, do not reset it. Note the code and arrange a diagnosis. Do not follow the steps for a different model. Any homeowner step for LC depends on which model you have.
- Is it worth repairing?
- Whether Gree LC is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on LC.Gree by age, from our Gree page:
Gree repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair sensor, fan and minor electrical faults. Over 8 years A compressor or inverter fault on a budget-tier system can reach replacement cost. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing Gree LC before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page. On a Gree VRF system, we service but do not repair, so that fault goes to Gree's authorised agent.
What Does Gree LC Mean?
Gree LC means compressor start failure on Multi GEN2 wall mount, Multi GEN2 cassette and Multi GEN2 slim duct and other models. Other Gree models list a different meaning for LC; match the model first.
What Causes Gree LC?
Gree's fault list for Multi GEN2 wall mount gives the meaning of Gree LC but not its causes. A technician finds the cause by measurement against the service manual for the installed model.
Which Gree LC Meaning Matches Your Unit?
Gree LC has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means |
|---|---|
| U-Match duct type | Start-up failure |
| Multi GEN2 wall mount | Compressor start failure |
| Ultra Heat GMV6 Mini VRF (2024) | IDU is not matching with outdoor unit |
- Model / series
- U-Match duct type
- What it means
- Start-up failure
- Model / series
- Multi GEN2 wall mount
- What it means
- Compressor start failure
- Model / series
- Ultra Heat GMV6 Mini VRF (2024)
- What it means
- IDU is not matching with outdoor unit
Show 2 more meanings
| Model / series | What it means |
|---|---|
| MultiPRO / GMV VRF II R410A | Indoor-unit model cannot match the outdoor-unit model |
| Multi ECO R32 multi-zone / All Match floor / ceiling R32 | Compressor start-up failure |
- Model / series
- MultiPRO / GMV VRF II R410A
- What it means
- Indoor-unit model cannot match the outdoor-unit model
- Model / series
- Multi ECO R32 multi-zone / All Match floor / ceiling R32
- What it means
- Compressor start-up failure
What Does a Technician Check for Gree LC?
Before quoting parts for Gree LC, a technician should match LC to your exact model before choosing what to test.
Follow that model's service procedure for LC and quote parts only on measured evidence.
Do not apply a sensor, drain, valve, fan, compressor, electrical, or reset procedure meant for a different model.
| Detail | What it says |
|---|---|
| Diagnostic note | Check compressor wiring, stop duration, refrigerant charge, and outdoor drive board. |
- Detail
- Diagnostic note
- What it says
- Check compressor wiring, stop duration, refrigerant charge, and outdoor drive board.
Will Gree LC Need a Repair or a New Unit?
Gree LC names a different fault on different models, not a failed part. Approve parts only once tests on your model show the cause of LC; compare repair cost with system age only after that.