Gree Aircon Compressor Repair in Singapore
Weak cooling, protection trips and compressor codes on a Gree can come from the compressor, its starting circuit, the inverter board or low gas. We test those first, because a compressor replacement is the largest repair on an aircon.
On-site check: $30 / visit. Visit fee waived if you proceed with the quoted work.
Signs Your Gree Aircon Needs a Compressor Check
The Aircon Runs but Does Not Cool
The indoor fan may still blow while the outdoor unit struggles to start, stops early or produces little cooling.The System Shuts Down or Trips
Repeated stopping, protection trips or a breaker trip needs testing before the system is restarted again.An Error Code or Unusual Outdoor Noise Appears
A Gree fault code, hard starting, loud vibration or a sudden change in outdoor-unit sound helps narrow the check.
Service Scope
Find the cause
We test power, the starting circuit or inverter board, and the compressor itself. We also check airflow and refrigerant readings.
Confirm the repair and quote
We quote the repair and confirm parts and lead time before you approve. If the compressor needs replacing, we match it to the system and check that it starts and cools after fitting.
Workmanship Warranty
Labour
30-day workmanship warranty. If the same fault returns from our repair, we come back and the labour is on us, with no second on-site check fee.
Parts
Parts carry the distributor's warranty for that component, so the term varies by part. We tell you both terms before you approve the work.
Photos from Recent Jobs
What Customers Say
“Great people and process. Booked their $30 check when my air conditioner could not switch on. They traced the problem to wiring. No upsell, no drama. Repair done same day, check fee waived. Everything upfront, no hidden cost. Definitely would use their services again! 5/5”
Yong Jun YeoGoogle “The installer for my new aircon had done a brillant job and the communication had been seamless as well. I am happy in engaging their service!😄”
cz0903Carousell “Repeated the chemical wash today. Their professional team made sure there was minimal mess and dirt during the process. Can really feel the difference, the aircon feels much better after the servicing. Very satisfied with their service!”
jonathan limGoogle “they are amazingly on time, and very upfront on the prices. Friendly disposition and they provided valuable advices. i like how that they only sell what you need. Just awesome!”
makchique_specsCarousell “Customer service was prompt and responsive throughout. Guys came on time, helped to advise on the proper cleaning and relocation, even helped me to save money. Highly recommended!”
A NGoogle “The guys at Snowflake go above & beyond in terms of customer service. I had contacted them due to my aircon unit leaking. The guys spent an hour doing chemical clean. However my unit starting leaking again that night. Snowflake were extremely proactive by sending same guys next guy to fix the problem. They located pipe outside & cleared it. Really highly recommend 👍🏼🤩”
nazzasgCarousell “For our 1 year contract, we are satisfied with the efficiency and skilled of the technicians who maintained our aircon. Easy to schedule and coordinate. Hence, we will re contract for another year. Thanks for your service.”
Marian ArcaoGoogle “Fast and efficient service! 100% satisfied with the fast work! Arrived on time and work done was very professional for our commercial unit! Even provide us with new controller (at a price) cause ours didnt work anymore! 😔”
baecaresgCarousell “Used them a few times, very pleased with service level and prices. They provide honest advice on what is needed or not. Plus, they always bring a tarp to cover surfaces. No dodgy upselling practices. Recommended. Will continue to engage their service.”
HW LGoogle “Angeline is very patient in answering all my queries via chat. Tony came to check and does the necessary and give really good recommendation and advices on what is really needed to be done. Recommended 👍”
lill.yCarousell “Excellent Experience Installing System 3 Air Conditioner Knowledgeable, flexible, and efficient service.”
David NgGoogle “Excellent service, able to solve our problem with the aircon removal professionally and goes the extra mile to help us! Would recommend 101%! 💯💯”
kullookCarousell “Mr Yi Tat & Mr Kian were very efficient at servicing 4 ACs within 2 hours! They were very friendly and extremely easy to communicate with throughout the process. Will definitely call them back for future servicing. Thank you, gentlemen!”
Murshidah MunibGoogle “Engaged them because of good reviews and truly they deserved the good reviews. Tony and Ian were able to rectify my problems (other technician was not able to pin point the fault). Repaired and service with resonable charges. Thanks Tony and Ian for solving my issue. 🙏”
ngeokhimCarousell “My go to Aircon servicing for years on. Always prompt in responses and punctual on day if servicing. If delays are expected, they will update via WhatsApp. Never upsell and is honest and dependable. I always have Yen for my servicing. great guy!”
Joanne CGoogle “Technician came within the time frame that they provided and the technician even go extra miles in cleaning and wiping the surrounding areas after chemical wash. Servicing is indeed good”
SharonnczyCarousell “The technician explained their solution thoroughly and their price is transparent. Recommended”
Zi Hao TanGoogle “trusted,easy&fast reply..e service was excellent..e servicing man advice abt my aircon..no messy dust..👍 now my 3 unit aircon getting much colder...tqsm..(will deal wif u again)❤”
idaomrsleeCarousell “Great service! The response was very fast and they arranged the repair quickly. The technician was experienced and knew exactly what to do. Everything was fixed efficiently and the pricing was very reasonable. Definitely value for money—highly recommended!”
Alex LuGoogle “Thumbs up for snowflake aircon service. Delayed a bit on the arrival but they are able to inform prehand. Their guys are very professional to recommend what's the best solution for me. Reasonable price with quality work. Will surely engage them again :)”
ivanaviCarousell “My family has been going back to them for 10 years+. Service is always amazing and the people are very friendly 🤗🤗”
naurahGoogle “Prompt arrival and professional service. Been engaging them for 3 years now. Highly recommend! 👍”
luckyzackyCarousell
Checks, models and error codes
Is Gree Compressor Repair Worth It?
Compressor repair is usually sensible when the rest of the system is healthy, the correct part is available and the quote is reasonable for the unit's age.
| System age | Usual call |
|---|---|
| Under 5 years | Repair. |
| 5-8 years | Repair sensor, fan and minor electrical faults. |
| Over 8 years | A compressor or inverter fault on a budget-tier system can reach replacement cost. |
Reasons for each row: full Gree table.
You can wait
Cooling is weaker but the outdoor unit starts and runs steadily. Book a diagnosis, and note whether cooling keeps falling.
Do not wait
The outdoor unit repeatedly shuts down mid-cycle or will not start. Switch the aircon off at the remote and leave it until it is tested.
Where the outdoor unit hangs on the outside of the building, the work is high-risk work at height. If its bracket is corroded or loose, a BCA-trained air-con installer must fix it before servicing work goes ahead. Source: MOM and BCA circular, 3 Jun 2024, checked 21 Nov 2026.
On-site check $30 / visit, waived if you go ahead with the quoted repair. Rates as of 20 Nov 2026. See our aircon system replacement process.
It May Not Be the Compressor
Capacitor, Relay or Power Fault
A weak starting component or unstable supply can stop a healthy compressor from starting correctly.Inverter PCB or IPM
A driver-stage fault can produce the same no-start or overcurrent symptoms as a compressor failure.Airflow, Pressure or Refrigerant Condition
A dirty coil, failed outdoor fan, restriction or leak can trigger compressor protection without internal damage.
What Is Different on Gree Systems
Gree pressure and compressor protections are not automatic gas-top-up instructions. Airflow, fan operation and measured refrigerant conditions come first.
Examples of Gree Systems We Check
Lomo Residential Single-Split Systems
Free Match Residential Multi-Split Systems
U-Match and Gree Commercial Families, with Scope Confirmed from the Exact Model
Model not listed
Message us the error code or what the unit is doing. A photo or short video helps if you have one.
Parts and timing
Gree parts availability is model-dependent. The indoor model, outdoor model and board or motor part number are needed before availability is promised.
Gree Error Codes Related to Compressor Problems
Choose where the code appeared on your unit.
Outdoor unit28 guides
- E4Compressor high discharge temperature protection; High discharge temperature protection of compressor
- H3Compressor overload protection; Overload protection of compressor
- H5IPM or power-module protection; IPM protection
- H7Drive desynchronizing protection; Compressor desynchronizing
- HCPFC protection
- HECompressor demagnetization protection
- J1Over-current protection of compressor 1; Overcurrent protection of compressor 1
- LCStart-up failure; Compressor start failure
- LDCompressor phase protection; Compressor lost-phase fault
- P0Drive reset protection; Malfunction of driving board of compressor
- P1Driving board of compressor operates abnormally; Compressor driving board operates abnormally
- P2Voltage protection of driving board power of compressor; Compressor driving-board power-voltage protection
- P3Reset protection of driving module of compressor; Reset protection of compressor driving module
- P4Drive PFC protection of compressor; Compressor drive PFC protection
- P5Compressor phase current protection; Over-current protection of inverter compressor
- P6Drive IPM module protection of compressor; Compressor drive IPM-module protection
- P8Drive IPM high temperature protection of compressor; Module high-temperature protection
- P9Desynchronizing protection of inverter compressor
- PAMalfunction of drive storage chip of compressor
- PCMalfunction of current detection circuit drive of compressor; Compressor drive current-detection circuit malfunction
- PEPhase-lacking of inverter compressor; Phase loss of inverter compressor
- PFMalfunction of charging loop of driven of compressor; Compressor drive charging-circuit malfunction
- PHHigh-voltage protection of compressor’s drive DC bus bar; High-voltage protection of compressor drive DC bus
- PJFailure startup of inverter compressor; Failure to start inverter compressor
- PLLow voltage protection for DC bus bar of drive of compressor; Low-voltage protection of compressor drive DC bus
- PPAC current protection of inverter compressor; AC-current protection of inverter compressor
- PUAC input voltage of drive of inverter compressor; Capacitor-charging malfunction
- U2Compressor lost-phase protection
Whole-system faults7 guides
- E5Over-current protection; Overcurrent protection
- E8High-temperature resistance protection
- EEEEPROM malfunction
- L9High-power protection
- U1Phase current detection circuit malfunction for compressor; Compressor phase-current detection-circuit malfunction
- U3DC bus voltage-drop malfunction
- U5Complete-unit current-detection malfunction
Codes that depend on the exact model1 guide
Every code is in the full lookup for this brand. Last reviewed 2026-08-21.
Other Gree Repair Checks
Find the service that matches a different fault on the same brand of aircon.
Frequently Asked Questions
How do you confirm a Gree compressor fault?
Is a Gree error code enough to order the compressor?
Should I repair or replace my Gree aircon?
Ready to Get Started?
Include model and error code or light.