Gree Aircon PE Error Code
Gree PE means temperature excursion protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models. If this meaning of PE matches your model, do not reset it.
- What it means
- Temperature excursion protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models. Other Gree models list a different meaning for PE; match the model first.
- Is it serious?
- Yes. Gree PE is a high-severity refrigerant or pressure fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- If this meaning of PE matches your model, do not reset it. Note the code and arrange a diagnosis. Do not follow the steps for a different model. Any homeowner step for PE depends on which model you have.
- Is it worth repairing?
- Whether Gree PE is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the refrigerant circuit. A leak has to be found and sealed before any gas goes in, and the leak's location sets most of the cost. The code names the fault, not the failed part, so measure before you decide on PE.Gree by age, from our Gree page:
Gree repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair sensor, fan and minor electrical faults. Over 8 years A compressor or inverter fault on a budget-tier system can reach replacement cost. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing Gree PE before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page. On a Gree VRF system, we service but do not repair, so that fault goes to Gree's authorised agent.
What Does Gree PE Mean?
Gree PE means temperature excursion protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models. Other Gree models list a different meaning for PE; match the model first.
What Causes Gree PE?
Gree's fault list for U-Match duct type gives the meaning of Gree PE but not its causes. A technician finds the cause by measurement against the service manual for the installed model.
Which Gree PE Meaning Matches Your Unit?
Gree PE has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means |
|---|---|
| U-Match duct type | Temperature excursion protection |
| Ultra Heat GMV6 Mini VRF (2024) | Phase-lacking of inverter compressor |
| MultiPRO / GMV VRF II R410A | Phase loss of inverter compressor |
- Model / series
- U-Match duct type
- What it means
- Temperature excursion protection
- Model / series
- Ultra Heat GMV6 Mini VRF (2024)
- What it means
- Phase-lacking of inverter compressor
- Model / series
- MultiPRO / GMV VRF II R410A
- What it means
- Phase loss of inverter compressor
What Does a Technician Check for Gree PE?
Before quoting parts for Gree PE, a technician should match PE to your exact model before choosing what to test.
Follow that model's service procedure for PE and quote parts only on measured evidence.
Do not apply a sensor, drain, valve, fan, compressor, electrical, or reset procedure meant for a different model.
| Detail | What it says |
|---|---|
| Diagnostic note | Check temperature readings, airflow, and refrigerant-side condition. |
- Detail
- Diagnostic note
- What it says
- Check temperature readings, airflow, and refrigerant-side condition.
Will Gree PE Need a Repair or a New Unit?
Gree PE names a different fault on different models, not a failed part. Approve parts only once tests on your model show the cause of PE; compare repair cost with system age only after that.