Gree Aircon PA Error Code

Gree PA means AC current protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models. If this meaning of PA matches your model, do not reset it.

What it means
AC current protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models. Other Gree models list a different meaning for PA; match the model first.
Is it serious?
Yes. Gree PA is a high-severity electrical fault. Have it diagnosed before relying on the unit.
Can I keep running it?
If this meaning of PA matches your model, do not reset it. Note the code and arrange a diagnosis. Do not follow the steps for a different model. Any homeowner step for PA depends on which model you have.
Is it worth repairing?
Whether Gree PA is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the power supply or an electrical circuit. If the cause is a failed board, it is replaced, not repaired; a wiring or supply fault is a smaller repair. The code names the fault, not the failed part, so measure before you decide on PA.Gree by age, from our Gree page:
Gree repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsRepair.
5-8 yearsRepair sensor, fan and minor electrical faults.
Over 8 yearsA compressor or inverter fault on a budget-tier system can reach replacement cost.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Gree PA before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page. On a Gree VRF system, we service but do not repair, so that fault goes to Gree's authorised agent.
On this page

What Does Gree PA Mean?

Gree PA means AC current protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models. Other Gree models list a different meaning for PA; match the model first.

What Causes Gree PA?

Gree's fault list for U-Match duct type gives the meaning of Gree PA but not its causes. A technician finds the cause by measurement against the service manual for the installed model.

Which Gree PA Meaning Matches Your Unit?

Gree PA has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    U-Match duct type
    What it means
    AC current protection
  • Model / series
    Ultra Heat GMV6 Mini VRF (2024)
    What it means
    Malfunction of drive storage chip of compressor

What Does a Technician Check for Gree PA?

Before quoting parts for Gree PA, a technician should match PA to your exact model before choosing what to test.

  • Follow that model's service procedure for PA and quote parts only on measured evidence.

  • Do not apply a sensor, drain, valve, fan, compressor, electrical, or reset procedure meant for a different model.

  • Detail
    Diagnostic note
    What it says
    Check input current, compressor load, and outdoor drive circuit.

Will Gree PA Need a Repair or a New Unit?

Gree PA names a different fault on different models, not a failed part. Approve parts only once tests on your model show the cause of PA; compare repair cost with system age only after that.

Gree PA Questions

What does the Gree PA error code mean?
Gree PA means AC current protection on U-Match duct type, U-Match cassette type and U-Match floor/ceiling type models, according to Gree's fault list for U-Match duct type. Other Gree models list a different meaning for PA; match the model first.
Is it safe to keep running an aircon showing Gree PA?
Treat Gree PA as a fault to diagnose, not a display to clear. If this meaning of PA matches your model, do not reset it. Note the code and arrange a diagnosis. Do not follow the steps for a different model.
What causes Gree PA?
Gree's fault list for U-Match duct type gives the meaning of Gree PA but does not list its causes. A technician finds the cause by following the service manual for your exact model and measuring the unit, not from the code alone.
Is Gree PA worth repairing?
Whether Gree PA is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the power supply or an electrical circuit.
How much does it cost to find out what is causing Gree PA in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Gree PA before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.

Where to Go Next

Confirm the Fault

Message us the code and what the unit is doing, and we tell you the likely cause.

Not the Right Code?

Browse the full Gree list or check a few codes in the same fault category.

Read Next

Use these if the quote mentions the parts, checks, or repair path this code points to.