LG Aircon CH29 Error Code & Blinking Light
LG CH29 means inverter compressor amperage is too high on HSV4 / HSV5 single-zone wall-mounted systems. Switch the unit off if CH29 shows and leave it off.
- What it means
- Inverter compressor amperage is too high on HSV4 / HSV5 single-zone wall-mounted systems. Other LG models list a different meaning for CH29; match the model first.
- Is it serious?
- Yes. LG CH29 is a high-severity compressor fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- Switch the unit off if CH29 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the pattern. The manufacturer's fault list gives no homeowner fix for CH29, so leave it for diagnosis.
- Is it worth repairing?
- Whether LG CH29 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on CH29.LG by age, from our LG page:
LG repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair. 8-10 years This is the decision point. Over 10 years Replace after a major component failure. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing LG CH29 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page. On a LG VRF system, we service but do not repair, so that fault goes to LG's authorised agent.
What Does LG CH29 Mean?
LG CH29 means inverter compressor amperage is too high on HSV4 / HSV5 single-zone wall-mounted systems. Other LG models list a different meaning for CH29; match the model first.
What Causes LG CH29?
LG's fault list for HSV4 / HSV5 single-zone wall-mounted systems gives the meaning of LG CH29 but not its causes. These are typical for this fault type, not listed for CH29.
Compressor start, lock, overcurrent, overload, or inverter-drive protection.
Power-module, IPM, voltage, or wiring fault affecting compressor drive.
Compressor mechanical or winding issue after electrical checks are confirmed.
Which LG CH29 Meaning Matches Your Unit?
LG CH29 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means |
|---|---|
| HSV4 / HSV5 single-zone wall-mounted systems | Inverter compressor amperage is too high |
| LS091HSV / LS121HSV wall-mounted single-zone | Inverter compressor amperage too high |
| LG Multi V 5 commercial VRF: master outdoor unit: Inverter-compressor overcurrent fault | master outdoor unit: Inverter-compressor overcurrent fault |
- Model / series
- HSV4 / HSV5 single-zone wall-mounted systems
- What it means
- Inverter compressor amperage is too high
- Model / series
- LS091HSV / LS121HSV wall-mounted single-zone
- What it means
- Inverter compressor amperage too high
- Model / series
- LG Multi V 5 commercial VRF: master outdoor unit: Inverter-compressor overcurrent fault
- What it means
- master outdoor unit: Inverter-compressor overcurrent fault
Show 2 more meanings
| Model / series | What it means |
|---|---|
| LG Multi V 5 commercial VRF: slave 1 outdoor unit: Inverter-compressor overcurrent fault | slave 1 outdoor unit: Inverter-compressor overcurrent fault |
| LG Multi V 5 commercial VRF: slave 2 outdoor unit: Inverter-compressor overcurrent fault | slave 2 outdoor unit: Inverter-compressor overcurrent fault |
- Model / series
- LG Multi V 5 commercial VRF: slave 1 outdoor unit: Inverter-compressor overcurrent fault
- What it means
- slave 1 outdoor unit: Inverter-compressor overcurrent fault
- Model / series
- LG Multi V 5 commercial VRF: slave 2 outdoor unit: Inverter-compressor overcurrent fault
- What it means
- slave 2 outdoor unit: Inverter-compressor overcurrent fault
What Does a Technician Check for LG CH29?
Before quoting parts for LG CH29, a technician should confirm whether CH29 is compressor start, overload, lock, or drive protection.
Check supply voltage, inverter output, IPM status, compressor current, and winding readings.
Review trip history and compressor mechanical signs before quoting replacement.
| Detail | What it says |
|---|---|
| Diagnostic note | Stop repeated resets and arrange compressor current and inverter diagnosis if CH29 returns. |
- Detail
- Diagnostic note
- What it says
- Stop repeated resets and arrange compressor current and inverter diagnosis if CH29 returns.
Will LG CH29 Need a Repair or a New Unit?
LG CH29 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.