Mitsubishi Heavy Industries Aircon E47
Mitsubishi Heavy Industries E47 means active filter voltage error on Singapore Rocket YYS single split and SRK-YYS indoor with SRC-YYS outdoor models. Switch the unit off if E47 shows and leave it off.
- What it means
- Active filter voltage error on Singapore Rocket YYS single split and SRK-YYS indoor with SRC-YYS outdoor models. Other Mitsubishi Heavy Industries models list a different meaning for E47; match the model first.
- Is it serious?
- Yes. Mitsubishi Heavy Industries E47 is a high-severity electrical fault. Have it diagnosed before relying on the unit.
- Can I keep running it?
- Switch the unit off if E47 shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the pattern. The manufacturer's fault list gives no homeowner fix for E47, so leave it for diagnosis.
- Is it worth repairing?
- Whether Mitsubishi Heavy Industries E47 is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the power supply or an electrical circuit. If the cause is a failed board, it is replaced, not repaired; a wiring or supply fault is a smaller repair. The code names the fault, not the failed part, so measure before you decide on E47.Mitsubishi Heavy Industries by age, from our Mitsubishi Heavy Industries page:
Mitsubishi Heavy Industries repair-or-replace guidance by system age System age Usual call Under 5 years Repair. 5-8 years Repair unless the compressor or inverter board fails. 8-10 years Weigh the repair cost against the wait for MHI parts. Over 10 years A major component failure usually favours replacement. - What it costs to find out
- An on-site check in Singapore costs $30 and finds what is causing Mitsubishi Heavy Industries E47 before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
What Does Mitsubishi Heavy Industries E47 Mean?
Mitsubishi Heavy Industries E47 means active filter voltage error on Singapore Rocket YYS single split and SRK-YYS indoor with SRC-YYS outdoor models. Other Mitsubishi Heavy Industries models list a different meaning for E47; match the model first.
What Causes Mitsubishi Heavy Industries E47?
Mitsubishi Heavy Industries' fault list for Singapore Rocket YYS single split gives the meaning of Mitsubishi Heavy Industries E47 but not its causes. These are typical for this fault type, not listed for E47.
Compressor start, lock, overcurrent, overload, or inverter-drive protection.
Power-module, IPM, voltage, or wiring fault affecting compressor drive.
Compressor mechanical or winding issue after electrical checks are confirmed.
Which Mitsubishi Heavy Industries E47 Meaning Matches Your Unit?
Mitsubishi Heavy Industries E47 has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.
| Model / series | What it means | What to check first |
|---|---|---|
| Singapore Rocket YYS single split | Active filter voltage error | Match this meaning to your model and the unit that shows the code, then use the checks below. |
| Inverter PAC SRC outdoor diagnostics | Inverter overcurrent | Confirm the installed unit belongs to Inverter PAC SRC ZHX-S / ZIX-S / ZJX-S / ZMX-S / ZSX-S outdoor units before using this meaning. |
| Inverter PAC FDC outdoor diagnostics | Inverter overvoltage | Confirm the installed unit belongs to Inverter PAC FDC VA / VN / VNA / VNP / VS / VSA / VNX / VSX outdoor units before using this meaning. |
- Model / series
- Singapore Rocket YYS single split
- What it means
- Active filter voltage error
- What to check first
- Match this meaning to your model and the unit that shows the code, then use the checks below.
- Model / series
- Inverter PAC SRC outdoor diagnostics
- What it means
- Inverter overcurrent
- What to check first
- Confirm the installed unit belongs to Inverter PAC SRC ZHX-S / ZIX-S / ZJX-S / ZMX-S / ZSX-S outdoor units before using this meaning.
- Model / series
- Inverter PAC FDC outdoor diagnostics
- What it means
- Inverter overvoltage
- What to check first
- Confirm the installed unit belongs to Inverter PAC FDC VA / VN / VNA / VNP / VS / VSA / VNX / VSX outdoor units before using this meaning.
What Does a Technician Check for Mitsubishi Heavy Industries E47?
Before quoting parts for Mitsubishi Heavy Industries E47, a technician should confirm whether E47 is compressor start, overload, lock, or drive protection.
Check supply voltage, inverter output, IPM status, compressor current, and winding readings.
Review trip history and compressor mechanical signs before quoting replacement.
| Detail | What it says |
|---|---|
| Diagnostic note | Record the exact E-code and whether it came from the indoor display, wired remote, or outdoor PCB, then arrange diagnosis by a qualified Mitsubishi Heavy Industries technician. |
- Detail
- Diagnostic note
- What it says
- Record the exact E-code and whether it came from the indoor display, wired remote, or outdoor PCB, then arrange diagnosis by a qualified Mitsubishi Heavy Industries technician.
Will Mitsubishi Heavy Industries E47 Need a Repair or a New Unit?
Mitsubishi Heavy Industries E47 is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.