Toshiba Aircon 1C Error Code & Blinking Light

Toshiba 1C means compressor drive output error or abnormal voltage/current/frequency relationship on YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG models. Switch the unit off if 1C shows and leave it off.

What it means
Compressor drive output error or abnormal voltage/current/frequency relationship on YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG models. Other Toshiba models list a different meaning for 1C; match the model first.
Is it serious?
Yes. Toshiba 1C is a high-severity compressor fault. Have it diagnosed before relying on the unit.
Can I keep running it?
Switch the unit off if 1C shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the pattern. The manufacturer's fault list gives no homeowner fix for 1C, so leave it for diagnosis.
Is it worth repairing?
Whether Toshiba 1C is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair. The code names the fault, not the failed part, so measure before you decide on 1C.Toshiba by age, from our Toshiba page:
Toshiba repair-or-replace guidance by system age
System ageUsual call
Under 5 yearsRepair.
5–8 yearsRepair is cost-effective for most faults.
8–10 yearsRepair sensor, drainage and minor electrical faults.
Over 10 yearsA major component failure generally favours replacement.
What it costs to find out
An on-site check in Singapore costs $30 and finds what is causing Toshiba 1C before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.
On this page

What Does Toshiba 1C Mean?

Toshiba 1C means compressor drive output error or abnormal voltage/current/frequency relationship on YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG models. Other Toshiba models list a different meaning for 1C; match the model first.

What Causes Toshiba 1C?

Toshiba's fault list for YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG gives the meaning of Toshiba 1C but not its causes. These are typical for this fault type, not listed for 1C.

  • Compressor start, lock, overcurrent, overload, or inverter-drive protection.

  • Power-module, IPM, voltage, or wiring fault affecting compressor drive.

  • Compressor mechanical or winding issue after electrical checks are confirmed.

Which Toshiba 1C Meaning Matches Your Unit?

Toshiba 1C has more than one listed meaning. Your model, the system type and the unit that shows the code decide which one applies.

  • Model / series
    YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG
    What it means
    Compressor drive output error or abnormal voltage/current/frequency relationship
  • Model / series
    RAC TU2C-LINK Interface - Residential AC type
    What it means
    Compressor system or other error

What Does a Technician Check for Toshiba 1C?

Before quoting parts for Toshiba 1C, a technician should confirm whether 1C is compressor start, overload, lock, or drive protection.

  • Check supply voltage, inverter output, IPM status, compressor current, and winding readings.

  • Review trip history and compressor mechanical signs before quoting replacement.

  • Detail
    Diagnostic note
    What it says
    Remove the compressor lead for controlled testing, check inverter 3-phase output, compressor winding resistance, power supply, refrigerant load, and PMV operation where applicable.

Will Toshiba 1C Need a Repair or a New Unit?

Toshiba 1C is still a repair if power, inverter or module checks find the cause. Weigh compressor replacement against age, warranty and the rest of the system.

Toshiba 1C Questions

What does the Toshiba 1C error code mean?
Toshiba 1C means compressor drive output error or abnormal voltage/current/frequency relationship on YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG models, according to Toshiba's fault list for YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG. Other Toshiba models list a different meaning for 1C; match the model first.
Is it safe to keep running an aircon showing Toshiba 1C?
Treat Toshiba 1C as a fault to diagnose, not a display to clear. Switch the unit off if 1C shows and leave it off. Forcing a compressor or inverter fault to run adds to the damage. Do not power-cycle the unit to clear the pattern.
What causes Toshiba 1C?
Toshiba's fault list for YouMe 2.0 System 5 - RAS-5M51U2ACVG-SG gives the meaning of Toshiba 1C but not its causes. Typical causes for this fault type are compressor start, lock, overcurrent, overload, or inverter-drive protection; power-module, IPM, voltage, or wiring fault affecting compressor drive; compressor mechanical or winding issue after electrical checks are confirmed.
Is Toshiba 1C worth repairing?
Whether Toshiba 1C is worth repairing depends on the unit's age, the part that has failed, and that repair's cost against a new unit. For this fault type the part is usually in the compressor or its inverter drive. A confirmed compressor failure on an older unit is where a replacement is most often priced beside the repair.
How much does it cost to find out what is causing Toshiba 1C in Singapore?
An on-site check in Singapore costs $30 and finds what is causing Toshiba 1C before any repair is quoted. The fee is waived if you go ahead with the quoted work. Rates as of 20 Nov 2026, on our Pricing page.