What an installation price covers, line by line
The headline price usually covers the units, a set length of piping, trunking, drainage, mounting, vacuuming and testing. The lines below are the ones that most often appear on top.
Market ranges come from published Singapore operator rates. Snowflake Aircon Services' own extras are shown from its rate card.
Scroll to see more columns
| Line item | Market range in Singapore | Our rate | When it appears |
|---|---|---|---|
| Outdoor unit bracket | $130–$180 per unit | $200 / unit | Standard or stainless steel, where no safe bracket exists |
| Extra refrigerant piping past the included length | $15–$120 per metre | Long runs between indoor and outdoor units | |
| Isolator switch, 20A or 32A | $180–$600 per job | Larger units and multi-splits | |
| Dismantling an old unit, kept or disposed of separately | $50–$150 per unit | Replacing an existing system | |
| Disposal of the old unit | Operators price disposal together with removal or bundle it into a replacement; no three price it on its own. | Replacing an existing system | |
| Drain pipe extension | No published per-metre drain price was found; the length and how it is hidden set it. | Indoor unit far from a drain point | |
| Second trip, if needed | $150 / trip | Work that cannot finish in one visit |
Most quotes include a set piping length per indoor unit before the per-metre charge starts, and operators set that length differently. Snowflake's packages allow 50 feet of upgraded piping for each indoor unit.
Market ranges: published rates from 3 Singapore operators; published rates from 5 Singapore operators; published rates from 4 Singapore operators. Checked 20 Nov 2026.
Lines that should be in the headline price
Some steps are part of any proper installation. Ask why if a quote lists any of them as an extra.
- Vacuuming the piping before the gas is released.
- A leak and pressure check on the new joints.
- Trunking along the standard route.
- Commissioning: running every unit and checking it cools and drains.
Lines to ask about before you sign
Written answers to these make two quotes comparable.
- How many metres of piping are included per indoor unit?
- Is the old system dismantled and disposed of, and is that priced?
- Is a bracket needed, and what material is it?
- Does the electrical supply need an isolator or a new point, and who fits it?
- Is the piping new, or is the old piping being reused?
What Snowflake's packages include
Snowflake Aircon Services' packages cover one trip and a full standard installation, with 50 feet of upgraded piping allowed for each indoor unit. They also cover taking out and disposing of the old system, and vacuuming, testing and commissioning.
The bracket and the power point are not included, and a bracket is charged only if one is needed. Dismantling fees apply where no existing system is being replaced.