Which casement and window aircon models are sold in Singapore?
NEA's register holds 19 casement and window records, which are 17 distinct models: 12 casement and 5 window. Midea's MWAC-09PRO and MWAC-12PRO are each registered twice under separate registration numbers.
A casement unit fits an existing window or casement opening with no separate outdoor unit, as EuropAce describes it. Fujitech's NCB-07CI is a slim version made for sliding windows. The EuropAce range is covered in the europace aircon buying guide.
Scroll to see more columns
| Brand and model | Type | Ticks | Cooling capacity (kW) | Full-load COP | NEA label annual cost (S$, label figure) |
|---|---|---|---|---|---|
| PASECO PWA-3300W | Casement | 2 | 1.31 | 3.81 | 268 |
| EuropAce EAC8EUV | Casement | 2 | 1.69 | 3.79 | 356 |
| EuropAce EAC601D | Casement | 2 | 1.69 | 3.79 | 356 |
| SONA SCM 6228 | Casement | 2 | 2.06 | 3.81 | 435 |
| Bree BRE010CA | Casement | 2 | 2.1 | 3.79 | 437 |
| EIKOU EIK-07Cl | Casement | 2 | 2.1 | 3.79 | 437 |
| FUJITECH NCB-07CI | Casement | 2 | 2.1 | 3.8 | 437 |
| SONA SCM 6226 | Casement | 2 | 2.1 | 3.79 | 437 |
| EuropAce EAC 801A | Casement | 2 | 2.19 | 3.9 | 443 |
| EuropAce EAC10EUV | Casement | 2 | 2.19 | 3.9 | 443 |
| Tecno TAC 823i | Casement | 2 | 2.19 | 3.9 | 443 |
| Shinco KYC-26C/B7-FC | Casement | 2 | 2.49 | 3.85 | 506 |
| FUJITECH FW-08IVT | Window | 2 | 2.3 | 3.85 | 475 |
| Midea MWAC-09PRO | Window | 2 | 2.3 | 3.85 | 475 |
| Midea MWAC-12PRO | Window | 2 | 2.36 | 3.86 | 484 |
| FUJITECH FW-13IVT | Window | 2 | 2.37 | 3.86 | 484 |
| Midea MWAC-14PRO | Window | 2 | 4.3 | 4.22 | 798 |
How do you read ticks, COP and the label cost?
All 19 records carry 2 ticks. Compare full-load COP instead: the casement units run 3.79 to 3.9, the window units 3.85 to 4.22. Weighted COP is blank for every one.
Capacity is a rating in kW, not a room size, and the register gives no room size. To convert, 1 kW is 3,412 BTU/h, so 2.1 kW is about 7,165 BTU/h. Ask the seller for the room the unit is rated to cool.
The label cost is a test figure, not a quote or a bill. For single-phase units NEA's label assumes 27 cents per kWh, 8 hours of use daily and 16 hours of standby.
When is a casement or window unit the right buy, and when is a split better?
A casement or window unit suits a room that already has a casement slot or window opening and where an outdoor unit is not wanted.
Snowflake Aircon Services treats a split system as the better long-term fix when one unit has to carry a large room, or when the window is needed for light and ventilation. The portable aircon vs split system guide sets out that choice for the three formats.
Snowflake Aircon Services quotes casement and window installation. How a window aircon works as a machine is covered in its own guide.