Portable Aircon Models on the NEA Register: Ticks and kW

NEA's register lists 28 distinct portable aircon models from seven brands, and none rates above 2 ticks, so capacity and the label's running cost separate them. Sixteen sit at 1 tick and twelve at 2 ticks, from 1.9 kW to 4.7 kW.

On this page

Which portable aircon models are on the NEA register?

The register holds 29 portable records but 28 distinct models. Midea's MPPD-09CRN7-A appears twice under two registrations with identical figures, and the table counts it once.

EuropAce has 11 models, Midea 5, TCL 4, Novita 3, SONA 3, and iFan and Mistral one each. Each TCL record lists two model codes for one unit, shown as listed. The snapshot is dated 21 November 2026.

The Midea MPPT-14CRFN7-B lists a yearly figure about ten times its siblings', which looks like a register error, so its cost is left out. Confirm that model's figures with the supplier.

Scroll to see more columns

Which portable aircon models are on the NEA register? summary table
Brand and modelTicksCapacity (kW)NEA label annual cost (S$, label figure)
EuropAce EGAC10A612.06536
EuropAce EGAC10E6ION12.06536
EuropAce EGAC10E7ION11.9497
EuropAce EGAC10E8UV22.53615
EuropAce EGAC12A612.75710
EuropAce EGAC12D7F13.5891
EuropAce EGAC12E313.4883
EuropAce EGAC12E6ION12.7710
EuropAce EGAC12E8UV23.43828
EuropAce EGAC14E3141,049
EuropAce EGAC14F8INV24946
iFan IF9010A12.87757
Midea MPPD-09CRN7-A22.38536
Midea MPPD-11CRN7-A912.91741
Midea MPPT-12CRFN7-A22.99717
Midea MPPT-12CRFN7-B22.7607
Midea MPPT-14CRFN7-B22.99 (confirm with supplier)not shown (register figure looks wrong)
Mistral MPAC16GM14.71,230
Novita NAC10000UV-i22.81678
Novita NAC12000UV-i23.43828
Novita NAC14000UV-i141,049
SONA SACN 628222.53615
SONA SACN 628313.4883
SONA SACN 6284141,049
TCL TAC-09CPD/DM*, TAC-09CPD/DM422.53615
TCL TAC-12CPD/DM*, TAC-12CPD/DM413.39883
TCL TAC-12CPD/N*, TAC-12CPD/NZ23.43820
TCL TAC-14CPD/N*, TAC-14CPD/NZ141,049

How do you read the ticks on a portable aircon?

NEA rates portables on coefficient of performance, the cooling delivered per unit of electricity. A portable needs a COP of at least 3.0 to be sold. Below 3.25 it earns 1 tick, and 3.25 or above earns 2 ticks. The scale stops at 2.

For a climate voucher, the Climate Friendly Households page says 5-tick air-conditioners are eligible. It does not mention portables.

The label's annual cost assumes 8 hours of use a day at 27 cents per kWh. Treat it as a comparison figure, not a quote for your flat.

A single-duct portable also pushes its condenser air out of the room. The US Department of Energy found the resulting negative pressure draws outside air in, so cooling in the field can fall short of the rated capacity.

When is a portable the right buy, and when is a split better?

A portable suits a room used for a few hours, a rental where nothing may be fixed to the wall, or a stopgap before a proper installation. It needs a window or opening for the hose.

A room cooled most nights, or a bedroom where the hose and noise sit beside the bed, is the case for a split. Read portable aircon vs split system for the comparison, and the europace aircon buying guide if EuropAce is on your shortlist.

Snowflake Aircon Services leaves portable repairs to each brand's own service. Keep to the owner's manual for filters, the water tank and hose placement, and do not open the casing. For a fault, go to the supplier named on the warranty, or replace the unit.

Sizing a split starts with the number of rooms to cool and the type of home.

Common questions

How many portable aircon models are registered with NEA?
NEA's register, in its snapshot of 21 November 2026, holds 29 portable records covering 28 distinct models from seven brands. Midea's MPPD-09CRN7-A is registered twice with identical figures, which accounts for the difference. EuropAce has the most registered portables, with 11 models.
What do the ticks mean on a portable aircon?
Ticks on a portable aircon show its coefficient of performance: 1 tick from a COP of 3.0, and 2 ticks at 3.25 or above. NEA's scale for portables stops at 2 ticks, so a 2-tick portable carries the best rating any registered portable can have.
Does a single-hose portable cool as much as its rated capacity?
A single-hose portable can cool less than its rated capacity in a real room. Exhausting condenser air creates negative pressure, which draws outside air into the room. The US Department of Energy found this effect most pronounced for single-duct units.
Can a portable aircon qualify for a climate voucher?
Climate vouchers for air-conditioners cover units with a 5-tick rating, according to the Climate Friendly Households page, which does not mention portables. The best rating any registered portable carries is 2 ticks, so no portable on the current register reaches the 5-tick level the voucher page names.