Daikin Aircon Won't Turn On: Checks Before Booking a Repair

A Daikin that will not turn on is first checked for remote batteries, the timer setting, a power cut and a tripped breaker or blown fuse, the four checks in a Daikin operation manual. A breaker that has tripped stays off, and finding why is a technician's job.

On this page

Why won't my Daikin aircon turn on?

Daikin's operation manual for its FTX25KM and FTX35KM wall units, a European range, gives four checks when the unit does not operate and the operation lamp is off. A breaker is off or a fuse has blown, the power has failed, the remote has no batteries, or the timer is wrong.

What the operation lamp does narrows it further. Daikin separates a dead unit with the lamp off from one that stopped with the lamp on, and from one whose lamp is flashing.

Why won't my Daikin aircon turn on? summary table
What you seeWhat Daikin's manual saysNext step
Operation lamp off, no responseCheck the breaker or fuse, a power failure, remote batteries and the timerOwner checks below; a tripped breaker stays off
Remote display faint or blankThe batteries are dyingReplace both AAA batteries together
Stopped after a power cutResumes by itself in about 3 minutesWait before calling
Stopped suddenly, operation lamp onA large voltage swing stops it; resumes in about 3 minutesWait; repeated stops need a supply test
Stopped, operation lamp flashingDaikin lists filters and blocked inlets first; call the service shop if it keeps flashingRead the code, then book
Breaker, fuse or earth leakage breaker cuts off oftenCall the service shopLeave it off and book

What a Daikin owner can check safely

Start with the remote. Daikin Singapore blames a missed signal on flat batteries, a blocked receiver on the indoor unit or standing too far away. A daikin remote not responding can also be taken to Daikin's spare parts centre for checking.

Daikin's manual says a faint or blank remote display means the batteries are dying, and both AAA batteries go in new together. Changing them also wipes any ON or OFF timer from memory.

Timers matter more than they look. The manual says to set the timer again after a breaker trip, a power failure or a battery change. A forgotten timer can leave the unit idle.

Then look at the distribution board without touching it. If the aircon breaker or isolator has tripped, leave it off and book a check. The general page on an aircon cannot turn on covers the circuit side. A unit found dead after a service visit has its own page.

Keep it off or book: what a technician tests

Daikin's manual lists the signs that mean stop, turn the breaker off and call the service shop. They are a burning smell, a hot or damaged power cord, and a breaker, fuse or earth leakage breaker that keeps cutting out. It also says not to repair or modify the unit yourself.

A technician measures the supply from the breaker to the unit terminals before suspecting a part. Daikin's SM-TS3 code table then narrows the rest: U2 covers abnormal supply voltage or an instantaneous power failure.

U4 is a break in the indoor and outdoor link. Its causes include wiring faults, outdoor power switched off and a defective board. A1 points to the indoor board. A flashing lamp holds one of these codes, and the daikin blinking light guide shows how to read it.

Snowflake Aircon Services replaces a failed board rather than repairing it. The board is condemned only once the supply, fuse and wiring have tested clean.

Common questions

Why is my Daikin aircon not turning on at all?
A Daikin with its operation lamp off is checked for four things in Daikin's operation manual: a breaker that has turned off or a blown fuse, a power failure, missing or flat remote batteries, and a wrong timer setting. A tripped breaker stays off until a technician has found the cause.
Why is my Daikin remote not working?
Daikin Singapore gives three reasons a unit misses the remote signal: flat batteries, an object blocking the receiver on the indoor unit, or standing too far away. A faint or blank remote display means the batteries are dying, and Daikin advises fitting two new AAA alkaline batteries together.
Should I switch the breaker back on if my Daikin tripped it?
A tripped aircon breaker is best left off until a technician has tested the circuit and the unit. Daikin's operation manual tells owners to turn the breaker off and call the service shop when a breaker, fuse or earth leakage breaker keeps cutting off operation, or when there is a burning smell.
What does a technician check when a Daikin has no power?
A technician measures the supply from the breaker to the unit before suspecting a part. Daikin's SM-TS3 code table links U2 to abnormal supply voltage, U4 to a break in the indoor and outdoor link, and A1 to the indoor board, so the stored code points the test.