Mitsubishi Electric Aircon Won't Turn On: Causes and Repair

A Mitsubishi Electric aircon that will not switch on usually has a remote, power supply or safety switch problem, or a fault the unit reports through its lamps. A tripped breaker stays off until the circuit is tested.

On this page

Why won't my Mitsubishi Electric aircon turn on?

Mitsubishi Electric's Singapore FAQ names a faulty remote, a faulty receiver on the indoor unit, remote batteries that need replacing, or no power reaching the indoor unit. It also asks owners to see whether the power supply has tripped.

Blinking indoor lamps point elsewhere: the unit is reporting a fault or sitting on a safety switch. The general steps when an aircon cannot turn on apply to every brand; the table covers the Mitsubishi Electric signs.

Why won't my Mitsubishi Electric aircon turn on? summary table
What you seeLikely causeWho deals with it
No response to the remoteRemote batteries, the remote itself or the indoor receiverOwner changes the batteries; a technician tests the rest
Breaker or isolator trippedA fault on the aircon circuitLeave it off; a technician tests the circuit
Two indicator lights blinking non-stopFan coil safety switch not locked in, which is not a faultHave it secured in position
Operation lamp blinking a pattern, nothing runsWiring or signal between units, a sensor, the fan motor or the indoor boardA technician reads the code
Outdoor unit LED blinking, outdoor unit stoppedOutdoor power or control system, or the signal wiringA technician tests the outdoor unit

What an owner can check safely

Mitsubishi Electric says two continuously blinking fan coil lights mean the safety switch beside the louvers is not locked in, and that the unit is not faulty. It tends to follow work on the front panel, so ask whoever last serviced the unit to secure it.

What each blink count means is covered under starmex blinking light, not here.

  • Fit new batteries in the remote and try again.
  • Look at the DB box. If the aircon breaker has tripped, leave it in the off position and book a check.
  • Note whether the lamps are dark, lit or blinking, and count any blink pattern.
  • Note whether the outdoor unit makes any sound.

What a technician tests

The technician starts at the supply: whether power reaches the indoor and outdoor units, and why a breaker tripped.

Next is communication. For Starmex MSY-GP indoor units, Mitsubishi Electric's code sheet lists miswiring or a serial signal error among the reasons both units do not operate.

The same sheet lists the indoor and outdoor control systems. For both, its instruction is to replace the P.C. board, meaning the unit's circuit board.

Repair or replace when the board has failed

A failed board is replaced, not repaired. A board fault on its own does not make the whole system due for replacement; the age and condition of the compressor and coils decide that.

On a newer unit, read the mitsubishi electric warranty first. Mitsubishi Electric's terms run the limited warranty for 12 months from the purchase date and exclude units that have had unauthorised repairs.

Snowflake Aircon Services replaces failed boards and recommends Starmex for new installations, for its reliability, ease of servicing and parts supply, with Daikin quoted as the alternative.

Common questions

Why won't my Mitsubishi Electric aircon switch on?
Mitsubishi Electric's Singapore FAQ lists a faulty remote, a faulty receiver on the indoor unit, remote batteries that need replacing and no power supply to the indoor unit. The same answer asks owners to check the power supply for a trip, and a tripped aircon breaker should stay off until a technician tests the circuit.
Why are two lights blinking on my Mitsubishi Electric indoor unit?
Two indicator lights blinking continuously on a Mitsubishi Electric fan coil unit mean the safety switch on the left of the louvers is not properly locked in, according to Mitsubishi Electric. The switch is a safety device, the blinking stops once it is secured in position, and the unit itself is not faulty.
Should I switch the breaker back on if my aircon tripped it?
A breaker tripped by the aircon is best left off until a technician has tested the circuit. Mitsubishi Electric's FAQ treats a trip as a power supply cause, and switching it on again can repeat the fault on a unit with a wiring, motor or board problem.
Can a failed Mitsubishi Electric circuit board be repaired?
A failed Mitsubishi Electric board is replaced, not repaired. For Starmex single splits, Mitsubishi Electric's code sheet says to replace the indoor control board or the inverter board when the control system is at fault, once the wiring and sensors have been checked.