Why won't my Mitsubishi Electric aircon turn on?
Mitsubishi Electric's Singapore FAQ names a faulty remote, a faulty receiver on the indoor unit, remote batteries that need replacing, or no power reaching the indoor unit. It also asks owners to see whether the power supply has tripped.
Blinking indoor lamps point elsewhere: the unit is reporting a fault or sitting on a safety switch. The general steps when an aircon cannot turn on apply to every brand; the table covers the Mitsubishi Electric signs.
| What you see | Likely cause | Who deals with it |
|---|---|---|
| No response to the remote | Remote batteries, the remote itself or the indoor receiver | Owner changes the batteries; a technician tests the rest |
| Breaker or isolator tripped | A fault on the aircon circuit | Leave it off; a technician tests the circuit |
| Two indicator lights blinking non-stop | Fan coil safety switch not locked in, which is not a fault | Have it secured in position |
| Operation lamp blinking a pattern, nothing runs | Wiring or signal between units, a sensor, the fan motor or the indoor board | A technician reads the code |
| Outdoor unit LED blinking, outdoor unit stopped | Outdoor power or control system, or the signal wiring | A technician tests the outdoor unit |
What an owner can check safely
Mitsubishi Electric says two continuously blinking fan coil lights mean the safety switch beside the louvers is not locked in, and that the unit is not faulty. It tends to follow work on the front panel, so ask whoever last serviced the unit to secure it.
What each blink count means is covered under starmex blinking light, not here.
- Fit new batteries in the remote and try again.
- Look at the DB box. If the aircon breaker has tripped, leave it in the off position and book a check.
- Note whether the lamps are dark, lit or blinking, and count any blink pattern.
- Note whether the outdoor unit makes any sound.
What a technician tests
The technician starts at the supply: whether power reaches the indoor and outdoor units, and why a breaker tripped.
Next is communication. For Starmex MSY-GP indoor units, Mitsubishi Electric's code sheet lists miswiring or a serial signal error among the reasons both units do not operate.
The same sheet lists the indoor and outdoor control systems. For both, its instruction is to replace the P.C. board, meaning the unit's circuit board.
Repair or replace when the board has failed
A failed board is replaced, not repaired. A board fault on its own does not make the whole system due for replacement; the age and condition of the compressor and coils decide that.
On a newer unit, read the mitsubishi electric warranty first. Mitsubishi Electric's terms run the limited warranty for 12 months from the purchase date and exclude units that have had unauthorised repairs.
Snowflake Aircon Services replaces failed boards and recommends Starmex for new installations, for its reliability, ease of servicing and parts supply, with Daikin quoted as the alternative.