Why Is My LG Aircon Leaking Water, and When Did It Start?

Condensate has stopped getting out of your LG unit, and it is now finding another way down. Which stretch of the drain path gave way is usually settled by one question: when did the first drip appear?

On this page

Quick summary

An LG indoor unit drips when its drain clears water slower than the coil makes it, so cooling still works. The date of the first drip separates the cause: from new points at the drain's fall, days after a service at a reassembly slip, only in heavy rain at a drain with no headroom.

A Drain Is a Rate, Not an on or off Switch

Every cooling cycle condenses water vapour from the room on the coil. A tray collects the runoff and a pipe takes it outside, and that pipe has a speed limit.

Most indoor leaks are not a sealed pipe. They are a drain path clearing water slower than the coil makes it. The tray fills to the lip and the surplus goes over the edge. The room still cools while the unit drips.

Fix the Start Date Before You Study the Drip

Two questions do more than any inspection: the date of the first drip, and who had their hands in the unit shortly before it.

A unit that has dripped since new has a routing problem. One that started days after work has a reassembly problem. One that leaks only in bad weather has a load problem. A true blockage is different: it drips every time the unit runs, from the first minute, whatever the weather.

Fix the start date before you study the drip summary table
When the dripping happensWhat that points atWhat it gets mistaken for
Within weeks of a new installA drain run without steady fall along its whole lengthA defective unit for warranty
Within days of a service or washA connection left short of fully home on reassemblyA part that failed during the wash
Only in heavy rain or very humid spellsA drain that keeps pace at normal load but not at peakA blocked line
Slow at first, worse as the unit got more useWater pooling at a low spot that gravity used to clearA fault spreading inside the unit
Every time it runs, from the first minuteA genuine blockage or a broken section of pipeA timing or load problem

Rain-Linked Leaks Are the Drain Running Out of Headroom

Humidity links rain outside to water inside. Damp air carries more moisture, the coil pulls more out, and the tray fills faster than on a dry day. A drain that copes with an ordinary afternoon falls behind in a wet one.

Rainwater entering an exposed drain route, or condensation forming on exposed pipe, can mimic this. Tracing where the water starts separates them.

Ceiling cassettes and ducted units add a pump and float switch, because they sit above the drain. Wall units usually fall away by gravity.

The float switch trigger level can sit slightly high. The pump then starts on time on ordinary days and late on the heaviest, and water passes the tray lip first. Nothing has failed, and the ceiling is wet anyway.

A Pump Can Run Perfectly and Still Leak

A pump only moves water that reaches it. Where the drain line meets the pump chamber, a gap of a few millimetres sends part of the flow down inside the cabinet.

Testing the pump alone proves nothing then: it clears water at full rate while the unit keeps dripping. Check the inlet seating before pricing any pump.

Install Week and Service Week Are Where Most of These Begin

Drain faults are put there by hand. A pipe does not develop a wrong angle on its own, and a seated fitting does not work loose.

On a new install the usual error is fall. The line needs a steady drop along its full run, not only where it leaves the unit. One short uphill stretch looks fine at low volumes and pools once daily use raises them, so a unit can run dry for weeks and then drip. Nothing changed inside it. The water volume did.

After a service or chemical wash the usual error is reassembly: a hose at a shallower angle, a cover slightly out of line, a fitting short of home. It passes the visual check and shows itself on day three or four.

Give the date of the work and the date of the first drip. Whoever did the work is usually quickest at putting a slip right.

The Order This Should Be Checked In

The drain path is cleared or ruled out before the unit is opened. It takes minutes and holds the answer in most cases.

Fall first: follow the line from the tray outlet to its discharge for any level or uphill stretch. A dip holds water and a rise stops it.

Connections next: every joint fully seated, including the inlet at a pump chamber.

Then run under load. Cooling continues until the coil makes condensate at a realistic rate, with someone at the outlet throughout. A drain that swallows a poured jug can still fall behind a working coil on a humid day.

A tray, pump or coil is a fair question only after those three. A quote that opens with one of them has skipped the cheap part.

Common Questions

Why is my LG aircon leaking water?
An LG aircon leaks when the coil makes condensate faster than the drain can carry it away, so the tray overflows while cooling still works. The date of the first drip separates the causes: a unit that dripped from new has a routing problem, and one that started days after a service has a reassembly problem.
Why does my LG unit only drip in heavy rain?
An LG unit that drips only in heavy rain has a drain with little headroom: humid air loads the coil harder, the tray fills faster than on a dry day, and the drain falls behind at peak. Rain entering an exposed drain route can look the same, so the water is traced from where it starts.
Does a condensate pump rule out a leak?
A condensate pump on an LG cassette or ducted unit only moves water that reaches it. A gap of a few millimetres at the pump inlet sends part of the flow into the cabinet, so the pump clears at full rate while the unit still drips. Check the inlet seating before pricing any pump.
What should be checked before any LG part is quoted?
Before any LG part is quoted, the drain line's fall is checked from tray outlet to discharge, every connection is checked for full seating, and the unit is then run under load with someone watching the outlet. A tray, pump or coil is a fair question only after those three checks.