LG Aircon Not Cold: What Usually Causes It and the Repair

An LG aircon that runs without cooling usually has a dirty filter, a boxed-in outdoor unit, the wrong mode or low refrigerant. LG's CH codes separate the refrigerant, sensor and compressor faults that need a technician.

On this page

Why is my LG aircon not cold?

LG's troubleshooting pages for other markets start with airflow and settings: a dirty filter, curtains over the vents, something blocking the outdoor unit, or an energy-saving or low-noise mode. When the outdoor unit runs normally and the air still blows warm, LG says the refrigerant may be low.

Most other causes show up as a code. The table matches each cause to the CH codes LG publishes for it.

Why is my LG aircon not cold? summary table
CauseLG codeNext step
Dirty filter or blocked indoor ventsNoneFilter clean or servicing
Energy-saving or low-noise modeNoneSwitch to plain cooling mode
Outdoor unit overheating, poor ventilationCH61Book a check; do not climb onto the ledge to clear it
Refrigerant or compressor problem, often a leakCH38, CH32Leak test before any gas
Temperature sensor (thermistor) faultCH01, CH02, CH06, CH44 to CH46Sensor test and replacement
Compressor or its driveCH21, CH26, CH29Electrical tests, then repair or replace

What CH38 and CH32 point to

LG describes CH38 as the unit running low on refrigerant, and treats it as a protection warning. If it appears soon after installation or relocation, LG points to the piping connections and the installer.

CH32 means the inverter compressor's discharge pipe is too hot. LG's help page groups it with CH38 as a sign of low refrigerant, and its guidance is to stop using the aircon if the code persists.

Low gas means gas has escaped somewhere. Refrigerant goes back in only once the leaking joint or coil is located and repaired, otherwise the charge drains away again. Water dripping indoors is a drain fault, not a gas one, and the lg aircon leaking water page covers it.

Which codes point to a sensor or the compressor?

A thermistor is a temperature sensor. LG's codes CH01, CH02 and CH06 flag a disconnected or shorted sensor in the indoor unit, and CH44 to CH46 the same in the outdoor unit.

CH26 means the inverter compressor has seized or is not turning, and CH29 that it is drawing too much current. CH21 is a DC peak or IPM fault in the compressor drive. These are tested electrically before anyone condemns the compressor, and a failed board is replaced, not repaired.

Read the code against LG error codes for your model, and write it down while it is on the display.

Repair or replace under LG's Singapore warranty

LG Singapore gives every residential aircon type one year of warranty. The compressor motor parts carry five years, but labour and transport are charged from the second to the fifth year. Gas is listed as a consumable outside the cover.

So a compressor failure in years two to five still has a bill, though not for the part. Registration and the warranty card decide whether a claim stands, and the lg aircon warranty guide covers those conditions.

Six of the 11 LG models on NEA's register are multi-splits. On those, note which rooms are warm before the visit, because one indoor head and the shared outdoor unit are tested differently.

A sensor or a joint leak is normally worth fixing, and a failed board is replaced with a new one. A diagnostic visit reads the CH code and tests the circuit before a quote.

Common questions

Why is my LG aircon running but not cold?
LG lists a dirty filter, blocked vents, an obstructed outdoor unit and energy-saving or low-noise modes as common causes. When the outdoor unit runs normally and the air stays warm, LG says the refrigerant may be low, which needs a leak test by a technician.
What does CH38 mean on an LG aircon?
CH38 on an LG aircon is a low-refrigerant warning that protects the unit from damage. LG links it to the piping connections when it appears after installation or relocation, and advises stopping use if it persists, because the leak has to be located and repaired before refrigerant is added.
Does LG's warranty cover a compressor that stops cooling?
LG Singapore covers compressor motor parts for five years, against one year for the rest of the aircon. From the second to the fifth year, labour and transport are charged, and refrigerant is a consumable outside the warranty, so a compressor claim in that period still carries a bill.
Can a gas top-up fix an LG aircon that is not cold?
A gas top-up restores cooling only for a while when the refrigerant escaped through a leak. LG codes such as CH38 and CH32 point to low refrigerant, so the leaking joint or coil is repaired first, and sensor or compressor faults are ruled out before any gas goes in.