Starmex MXY-3H28VG vs MXY-4H38VG: System 3 vs System 4

Mitsubishi Electric Starmex MXY-3H28VG outputs 6.56 kW across three ports (S$3,750 nett with three MSXY-FP10VG heads). MXY-4H38VG outputs 8.05 kW across four ports (S$4,700 nett with four MSXY-FP10VG heads). Both hold NEA 5-tick labels and qualify for S$400 Climate Vouchers until December 2027.

On this page

Quick summary

Mitsubishi Starmex MXY-3H28VG (6.56 kW, COP 6.05) and MXY-3H28VG2 (6.45 kW, COP 6.07) fit 3-room and bedroom-only 4-room HDB flats at S$3,750 nett. MXY-4H38VG jumps to 8.05 kW (COP 6.19) for S$4,700 nett, giving fourth-room coverage and living-hall headroom while staying NEA 5-tick.

NEA 5-Tick Specs: MXY-3H28VG, MXY-3H28VG2, and MXY-4H38VG

All three Starmex outdoor condensers use R32 refrigerant and carry NEA 5-tick labels (NEA register checked 24 Nov 2026). Moving from MXY-3H28VG to MXY-4H38VG adds a fourth port and 1.49 kW of cooling output.

MXY-4H38VG posts a higher weighted COP (6.19 vs 6.05), even though its NEA annual figure is 508 kWh higher. NEA tests larger condensers at higher cooling loads, so total kWh rises with capacity rather than lower efficiency.

Scroll to see more columns

NEA 5-tick specs: MXY-3H28VG, MXY-3H28VG2, and MXY-4H38VG summary table
Specification (NEA checked 24 Nov 2026)MXY-3H28VG / SG2MXY-3H28VG2MXY-4H38VG
System class and portsSystem 3 (up to 3 heads)System 3 (up to 3 heads)System 4 (up to 4 heads)
NEA tick rating5-tick5-tick5-tick
Rated cooling capacity6.56 kW6.45 kW8.05 kW
Weighted COP6.056.076.19
NEA annual electricity2,418 kWh/yr (~S$753/yr)2,389 kWh/yr (~S$744/yr)2,926 kWh/yr (~S$912/yr)
NEA Certificate of RegistrationMELS-MIT-AC190018MELS-MIT-AC230005MELS-MIT-AC190008
Snowflake published nett installS$3,750 (3 x MSXY-FP10VG)S$3,750 (3 x MSXY-FP10VG)S$4,700 (4 x MSXY-FP10VG)

Upfront Price Gap and 2026 SP Group Running Costs

Snowflake's rate card (checked 24 Nov 2026) prices Starmex System 3 (3 x MSXY-FP10VG) at S$3,750 nett and System 4 (4 x MSXY-FP10VG) at S$4,700 nett. The S$950 gap pays for the fourth head, piping, and larger 8.05 kW condenser.

Annual estimates above use SP Group's Q4 2026 rate of 31.16 cents/kWh with GST (October to December 2026). Running two bedrooms at night draws nearly the same power on both units because the inverter slows down to match load.

Both MXY-3H28VG and MXY-4H38VG qualify for S$400 Climate Vouchers until 31 December 2027. Just confirm your exact indoor-outdoor set stays 5-tick at a participating retailer.

MXY-3H28VG vs MXY-3H28VG2 and Singapore Flat Sizing

Quotes in Singapore show both MXY-3H28VG (or MXY-3H28VG-SG2, COR MELS-MIT-AC190018) and the newer MXY-3H28VG2 (COR MELS-MIT-AC230005). Their cooling gap is tiny: 6.56 kW vs 6.45 kW. MXY-3H28VG2 edges ahead on COP (6.07 vs 6.05) and trims 29 kWh/yr.

Pick System 3 when you cool three bedrooms in a 4-room flat or two bedrooms plus a 3-room hall. Pick MXY-4H38VG when you want three bedrooms and the living hall on one outdoor unit.

Which Starmex Condenser Suits Your Flat and What to Do Next

Pick MXY-3H28VG or MXY-3H28VG2 if three heads cover every room you cool at S$3,750 nett. Pick MXY-4H38VG for four heads and 8.05 kW of living-hall muscle. Run four quick checks first:

  • Note which rooms run together from 1 pm to 6 pm versus after 9 pm so outdoor kW fits peak heat.
  • Match the NEA COR code (MELS-MIT-AC190018, AC230005, or AC190008) on your invoice for S$400 vouchers.
  • Check HDB aircon ledge space and isolator rating so the larger System 4 exhaust stays clear.
  • Book Snowflake's S$30 walkthrough (deducted on install) to verify piping, brackets, and nett rates.

Common Questions

What is the difference between MXY-3H28VG and MXY-3H28VG2 in Singapore?
MXY-3H28VG (COR MELS-MIT-AC190018) is rated at 6.56 kW with 6.05 weighted COP and 2,418 kWh/yr, while MXY-3H28VG2 (COR MELS-MIT-AC230005) is rated at 6.45 kW with 6.07 weighted COP and 2,389 kWh/yr. Both are 5-tick R32 System 3 Starmex condensers eligible for S$400 Climate Vouchers.
Why does MXY-4H38VG have higher annual kWh than MXY-3H28VG despite a higher COP?
NEA computes annual energy use from each condenser's full rated cooling capacity over standard test hours. Because MXY-4H38VG delivers 8.05 kW compared to 6.56 kW on MXY-3H28VG, its tested annual total is 2,926 kWh versus 2,418 kWh even though its 6.19 COP is more efficient per kilowatt.
Can MXY-4H38VG run all four rooms at the same time in a 4-room HDB flat?
With 8.05 kW of rated outdoor capacity, MXY-4H38VG handles three 9,000 BTU bedrooms plus a living hall far more comfortably than smaller 6.8 kW System 4 condensers. Running four units simultaneously in peak afternoon heat still shares that 8.05 kW pool, so room pull-down slows slightly.
How much more does Starmex System 4 cost than System 3 installed?
On Snowflake Aircon Services' published nett rate card, Starmex System 3 (3 x MSXY-FP10VG) is S$3,750 nett and System 4 (4 x MSXY-FP10VG) is S$4,700 nett, a S$950 difference. Brackets, a second trip, power points, and upsized living-room coils are quoted separately after a S$30 survey waived on install.