Panasonic CU-3XU28YBZ vs CU-4XU33YBZ vs CU-4XU38YBZ

Panasonic offers four NEA 5-tick R32 multi-split condensers: CU-2XU20YBZ (4.47 kW), CU-3XU28YBZ (6.55 kW), CU-4XU33YBZ (6.96 kW), and CU-4XU38YBZ (7.93 kW). Each pairs with nanoe X wall units and qualifies for S$400 Climate Vouchers until December 2027. Peak afternoon room load decides the right tier.

On this page

Quick summary

All four Panasonic YBZ R32 multi-split condensers carry NEA 5-tick labels and qualify for S$400 Climate Vouchers. CU-2XU20YBZ (4.47 kW) suits 2-room flats, CU-3XU28YBZ (6.55 kW) handles 3-room layouts, CU-4XU33YBZ (6.96 kW) fits staggered 4-room use, and CU-4XU38YBZ (7.93 kW, COP 5.78) covers simultaneous 4-room cooling.

Panasonic 5-Tick Multi-Split NEA Specs Side by Side

Every Panasonic YBZ multi-split condenser on the Singapore NEA register (checked 24 Nov 2026) uses R32 gas and scores 5 ticks. The -H variants share identical NEA Certificates of Registration, cooling output, COP, and annual kWh ratings.

Yearly power bills below use SP Group's Q4 2026 rate of 31.16 cents/kWh with GST (October to December 2026). Higher annual kWh on bigger units comes from larger rated cooling loads, not weaker efficiency.

Scroll to see more columns

Panasonic 5-tick multi-split NEA specs side by side summary table
Specification (NEA checked 24 Nov 2026)CU-2XU20YBZCU-3XU28YBZ / -HCU-4XU33YBZ / -HCU-4XU38YBZ / -H
System classSystem 2 (2 ports)System 3 (3 ports)System 4 (4 ports)System 4 (4 ports)
NEA tick rating5-tick5-tick5-tick5-tick
Rated cooling capacity4.47 kW6.55 kW6.96 kW7.93 kW
Weighted COP5.995.705.615.78
NEA annual electricity1,682 kWh (~S$524/yr)2,529 kWh (~S$788/yr)2,704 kWh (~S$843/yr)3,002 kWh (~S$935/yr)
NEA Certificate of RegistrationMELS-PAN-AC220030MELS-PAN-AC220035MELS-PAN-AC220034MELS-PAN-AC220036

Why CU-4XU33YBZ and CU-4XU38YBZ Suit Different 4-Room Flats

Both CU-4XU33YBZ and CU-4XU38YBZ run up to four XU nanoe X wall heads, yet their outdoor output differs sharply. CU-4XU33YBZ adds just 0.41 kW over the 3-port CU-3XU28YBZ (6.96 kW vs 6.55 kW).

That makes CU-4XU33YBZ right for shaded 4-room HDB flats that cool bedrooms overnight and switch to the hall by day. It is not built for running four west-facing rooms at 2 pm.

CU-4XU38YBZ jumps by 0.97 kW to 7.93 kW while lifting weighted COP from 5.61 to 5.78. Homes cooling an open living room plus a study or two bedrooms together get quicker pull-down while keeping 5-tick efficiency.

S$400 Climate Vouchers, Survey Quoting, and Upkeep

Eligible HDB flats and Singapore Citizen private homes can spend up to S$400 in Climate Vouchers until 31 December 2027 on NEA-listed 5-tick Panasonic sets at participating shops. Always verify that any mixed-BTU indoor pairing stays 5-tick.

Snowflake prices Panasonic multi-splits after a S$30 walkthrough survey, which is waived when you install. That site check confirms pipe length, HDB ledge clearance, and XU indoor head sizing upfront.

Routine general servicing stays on Snowflake's flat rate card (checked 24 Nov 2026): S$50 for one head, S$30 each for two, and S$25 each for three or more heads.

Which Panasonic 5-Tick Condenser Suits Your Flat and What to Do Next

Pick CU-2XU20YBZ for 2-room Flexi flats or dual-room studios. Choose CU-3XU28YBZ for three-bedroom use, CU-4XU33YBZ for staggered four-room schedules, and CU-4XU38YBZ for simultaneous hall and bedroom cooling. Check four items first:

  • Count how many rooms cool together during hot afternoons rather than counting total rooms.
  • Verify the NEA COR (MELS-PAN-AC220030, AC220035, AC220034, or AC220036) on your quote for S$400 vouchers.
  • Measure HDB ledge width and check isolator amps so CU-4XU38YBZ exhaust stays clear.
  • Book Snowflake's S$30 walkthrough (deducted on install) to compare Panasonic against Starmex System 3 (S$3,750) or System 4 (S$4,700).

Common Questions

Is CU-4XU38YBZ more efficient than CU-4XU33YBZ on the NEA register?
Panasonic CU-4XU38YBZ achieves a higher weighted COP of 5.78 compared with 5.61 on CU-4XU33YBZ, meaning it delivers more cooling per watt drawn. Its NEA annual energy estimate is higher (3,002 kWh vs 2,704 kWh) solely because NEA tests its larger 7.93 kW capacity at a heavier load.
Do the -H variants like CU-3XU28YBZ-H and CU-4XU38YBZ-H stay 5-tick?
NEA registers CU-3XU28YBZ-H, CU-4XU33YBZ-H, and CU-4XU38YBZ-H under the same 5-tick Certificates of Registration as the standard YBZ models (MELS-PAN-AC220035, AC220034, and AC220036). Confirm the exact paired indoor head codes on your retailer invoice before claiming S$400 Climate Vouchers.
When should a Singapore homeowner pick CU-2XU20YBZ over CU-3XU28YBZ?
Panasonic CU-2XU20YBZ (4.47 kW, weighted COP 5.99, 1,682 kWh/yr) fits 2-room Flexi HDB flats, compact condos, or dual-room clinics that only need two indoor heads. Stepping up to CU-3XU28YBZ (6.55 kW) makes sense only when a third room needs cooling.
How are Panasonic YBZ System 3 and System 4 installs priced at Snowflake?
Snowflake Aircon Services quotes Panasonic YBZ multi-split installs after a S$30 site survey, which is waived when you proceed with installation. The survey verifies HDB or condo pipe routes, condenser ledge clearance, bracket needs, and exact XU indoor head capacities.