Mitsubishi Electric MXY-4H38VG holds NEA 5-tick listing MELS-MIT-AC190008 at 8.05 kW cooling output, 6.19 weighted COP, and 2,926 kWh annual test draw. Snowflake's baseline Starmex System 4 package starts at S$4,700 nett, while MXY-4H38VG upgrades add living-room cooling muscle.
Inspect MXY-4H38VG Power Numbers and SP Electricity Estimates
Registered on NEA certificate MELS-MIT-AC190008 through 6 March 2028, MXY-4H38VG carries 5 green ticks at 8.05 kW capacity. Test efficiency hits 4.97 full load, 7.01 part load, and 6.19 weighted COP.
NEA posts 2,926 kWh yearly (S$790 label estimate). Using Singapore's Q4 GST-inclusive electricity tariff (31.16c/kWh), that test figure reaches S$912 annually. Cooling a single sleep room for 8h overnight draws around 2.9 to 3.3 kWh (S$27 to S$31 monthly).
Two sleep zones operating nightly add roughly S$51 to S$60 monthly. Active three-bedroom plus hall schedules land between S$90 and S$120 depending on west sun.
Compare Starmex System 4 Package Costs and Ownership Specs
Contrast Snowflake's S$4,700 FP10VG baseline System 4 deal with stepping up to the 8.05 kW MXY-4H38VG outdoor unit:
Scroll to see more columns
| Ownership benchmark | FP10VG x 4 System 4 baseline | MXY-4H38VG 8.05 kW step-up | Buyer decision factor |
|---|---|---|---|
| NEA MELS registration | 5-tick MXY-4H33VG class (6.93 kW) | MELS-MIT-AC190008 (8.05 kW) | +16% extra peak cooling headroom |
| Weighted / part-load COP | 5.76 weighted COP | 6.19 weighted | 7.01 part-load COP | Stronger efficiency per kW cooled |
| NEA annual kWh / SP Q4 rate | 2,646 kWh (~S$824/yr at 31.16c) | 2,926 kWh (~S$912/yr at 31.16c) | Higher kWh reflects 8.05 kW test load |
| Snowflake System 4 install rate | S$4,700 nett (4 x MSXY-FP10VG) | Quoted after S$30 site survey | 22 SWG copper + 0.5-inch Armaflex Shield CX |
| Climate Voucher & warranty | S$400 HDB voucher eligible | 1yr work / 1yr parts / 5yr compressor | Up to 50 ft pipe per head; brackets extra |
Weigh S$4,700 Baseline Installs, Climate Vouchers, and Parts
Snowflake's S$4,700 nett System 4 bundle includes four MSXY-FP10VG indoor blowers, old-unit removal, and vacuum commissioning. Piping uses thick 22 SWG copper tubes wrapped in half-inch Armaflex Shield CX insulation up to 50 ft per unit, plus 16 mm Class 0 drains. Stainless brackets (S$200) and second renovation visits (S$150) bill separately.
Qualifying HDB households offset S$400 via NEA Climate Vouchers against Starmex 5-tick hardware through December 2027. Upgrading from baseline System 4 to MXY-4H38VG prevents warm afternoons whenever MSXY-FP18VG or MSXY-FP24VG lounge coils run alongside bedrooms. Easy Clean front flaps and wide Singapore stock of sensors, motors, and boards simplify mid-life repairs.
Decide Between Baseline System 4 and MXY-4H38VG Upkeep
Size your outdoor chassis around afternoon living-room heat first, and budget maintenance using published flat tiers:
- Book our S$30 survey to verify ledge space and electrical isolators. Snowflake credits all S$30 directly once your Starmex installation or repair proceeds.
- Normal general maintenance across four Starmex indoor units drops to S$25 per unit. Pairing two units runs S$30 per unit, whereas single-unit visits run S$50 backed by a 14-day warranty.
- Eliminate sour fan odours and slow pull-down with chemical servicing. Three or more Starmex indoor units clean at S$60 per head, two at S$70 per head, and one at S$80 under a 60-day warranty.
- Severe blower mould requires full chemical overhauls off the wall. Cleaning three-plus wall units runs S$115 per blower, pairs run S$125 per blower, and an individual unit costs S$150 (90-day warranty).
Check Your Diagnostic or Servicing Price
Tap your job, unit count, and home type for our published Singapore rate — then send the pre-filled message on WhatsApp.
Published Singapore estimate
$30 / visit site survey (waived on installation)
Covers piping route check, condenser ledge access, and a firm nett package quote for your 3 indoor units.
1-year installation workmanship warranty + agent parts and 5-year compressor warranty.