Why won't my Panasonic aircon turn on?
When the unit does not work, Panasonic's Canadian operating instructions for its CS-E wall units name three things to look at. They are the remote batteries, a tripped circuit breaker and a timer that has been set.
The general power checks in aircon cannot turn on apply to every brand. Singapore models may differ from the Canadian and European units these sources cover. Panasonic adds its own lamp and timer signals, set out in the table.
| What happens | What Panasonic says | Next step |
|---|---|---|
| Remote display dim, or signal weak | Batteries inserted wrongly or weak | Fit new batteries of the same type |
| Remote works, unit ignores it | Receiver blocked, or some fluorescent lights interfering | Clear the receiver; consult a dealer if it persists |
| Aircon breaker tripped | Frequent trips need an authorised dealer | Keep it off; have the circuit checked |
| Power lamp blinks before the unit is on | Preparing to run because the ON timer is set | Normal, no action |
| Power lamp blinks slowly, long on and short off | Standby mode, per the service manual | Normal, no action |
| Cooling starts about 3 minutes after a stop | Compressor restart delay after a stop | Normal, wait it out |
| Unit stays off after a power cut | Automatic restart does not apply when a timer is set | Look at the timer settings |
| Unit stops and the timer lamp blinks | A fault code has been stored | Retrieve the code for the technician |
| Unit stops the moment it is switched on | An abnormality: stop using it | Switch off at the breaker; book a technician |
Checks that need no tools
A timer lamp that blinks after the unit stops is a stored code, not a timer setting.
- Fit new batteries of the same type. Panasonic warns that rechargeable Ni-Cd cells can damage the remote.
- Look at the aircon breaker in the DB box. If it has tripped, do not switch it back on; have the circuit tested.
- Make sure nothing blocks the indoor unit's signal receiver.
- Look at the timer settings on the remote. A power failure can cancel a timer, and Panasonic says it can be set again from the remote.
Leave it off, or keep trying?
Leave the breaker off when it trips. Panasonic lists a circuit breaker that switches off frequently among the conditions where power goes off at the breaker and an authorised dealer takes over.
The same holds for a burning smell, a power cord that turns abnormally hot, or a unit that stops as soon as it is switched on. For each, Panasonic tells owners to stop using the unit and turn off the breaker.
A wait after switching on again is normal. Panasonic's European service manual for its CS-E PKEW wall units holds the compressor off for 3 minutes from the moment operation stops.
What a technician tests, and when the board is replaced
The technician reads any stored code first; the codes and check mode are set out under panasonic check mode.
The European service manual sets H11 when the indoor and outdoor units fail to talk after a minute of running. The test then goes to the connecting wire, its terminals and the boards.
Panasonic's instructions leave repairs and internal cleaning to an authorised dealer or specialist, so keep the panels closed. Snowflake Aircon Services fits a new board when one has failed, and does not repair boards. On a unit still under cover, read the panasonic aircon warranty before booking.