Both 5-tick System 3 condensers deliver almost identical peak output (6.55 kW Panasonic CU-3XU28YBZ vs 6.56 kW Mitsubishi Electric MXY-3H28VG). Picking between them weighs Starmex's 6.05 weighted COP and quick flap care against Panasonic's nanoe X.

On this page

Quick summary

Both the 6.55 kW Panasonic CU-3XU28YBZ (5.70 COP, 2,529 kWh/yr) and 6.56 kW Starmex MXY-3H28VG (6.05 COP, 2,418 kWh/yr) deliver 5-tick cooling. Starmex saves 111 kWh yearly and cleans fastest, while Panasonic includes nanoe X.

Compare Cooling Output and HDB Flat Fit

Both condensers fit the exact same 3-room HDB, compact condo, and three-bedroom 4-room HDB layout. NEA MELS certificate MELS-PAN-AC220035 rates Panasonic CU-3XU28YBZ and CU-3XU28YBZ-H at 6.55 kW (valid until 10 May 2028). MXY-3H28VG from Mitsubishi Electric yields 6.56 kW capacity under registration MELS-MIT-AC190018 (valid through 27 March 2028).

A 0.01 kW gap equals roughly 34 BTU across three rooms, so pull-down cooling speed feels identical. Both sets require BCA-trained filing via HDB Form AC-02 and qualify for S$400 HDB Climate Vouchers until December 2027.

Side-by-Side Ownership Table: Panasonic CU-3XU28YBZ vs Starmex

Compare NEA metrics, SP Group Q4 2026 running costs (31.16c/kWh GST-inclusive), cleaning ergonomics, and upfront package options:

Side-by-side ownership table: Panasonic CU-3XU28YBZ vs Starmex summary table
Ownership factorPanasonic CU-3XU28YBZMitsubishi Starmex MXY-3H28VG
NEA MELS registrationMELS-PAN-AC220035 (5 ticks)MELS-MIT-AC190018 (5 ticks)
Rated cooling capacity6.55 kW6.56 kW
Full / part / weighted COP4.91 / 6.22 / 5.704.89 / 6.82 / 6.05
NEA annual kWh & SP bill delta2,529 kWh/yr (S$683 label)2,418 kWh/yr (saves ~S$35/yr at 31.16c)
Indoor hygiene & wash accessBuilt-in nanoe X (needs careful masking)Easy Clean flap opens wide for fast washes
SG parts depth & package rateOfficial Panasonic supply; survey quotedDeepest SG independent stock; S$3,750 nett

Weigh Part-Load Efficiency, Cleaning, and Spare Parts

Across ten years in an HDB home, Starmex holds a 6.82 part-load efficiency edge alongside faster cleaning. Bedrooms run at low speed overnight, cutting 111 kWh yearly (near S$35 on SP's 31.16c Q4 rate). Wide MSXY-FP10VG flaps and broad local stock also speed repairs.

Panasonic XU units appeal when households prioritise active nanoe X deodorising and Comfort Cloud apps. Remind technicians to mask ionizer plugs well before chemical washes.

Choose the Better System 3 for Your Flat and Check Rates

Pick Starmex MXY-3H28VG for effortless upkeep, deep local parts, and S$3,750 nett pricing with Armaflex Shield CX (half-inch) wrapping 22 SWG copper; pick Panasonic CU-3XU28YBZ when active air deodorising ranks highest:

  • Reserve Snowflake's S$30 survey to verify HDB ledge fit. That fee credits back onto the S$3,750 Starmex bundle (1-year work, 1-year parts, 5-year compressor) or any approved job.
  • Quarterly general servicing on three bedrooms totals S$75 (S$25 per room). Two rooms cost S$30 each, whereas one room costs S$50, all carrying 14-day warranty.
  • Chemical servicing runs S$60 each on 3+ bedrooms, or S$70 each across 2 bedrooms. Lone bedrooms run S$80, covered by a 60-day warranty.
  • Deep strip-down overhauls cost S$115 per room (three-plus). Pair visits cost S$125 per room, while lone-room overhauls cost S$150, carrying 90-day warranty.

Check Your Diagnostic or Servicing Price

Tap your job, unit count, and home type for our published Singapore rate — then send the pre-filled message on WhatsApp.

1. What do you need?
2. How many indoor units?
3. Property type & estate (optional)

Published Singapore estimate

$30 / visit site survey (waived on installation)

WhatsApp this estimate

Covers piping route check, condenser ledge access, and a firm nett package quote for your 3 indoor units.

1-year installation workmanship warranty + agent parts and 5-year compressor warranty.

Common Questions

Does Starmex MXY-3H28VG save noticeable money on SP Group bills versus Panasonic CU-3XU28YBZ?
Starmex MXY-3H28VG records 2,418 kWh yearly against 2,529 kWh on CU-3XU28YBZ in NEA testing. Priced against SP's 31.16c Q4 GST-inclusive rate, that 111 kWh gap equals roughly S$35 yearly. Extended overnight runs slightly widen savings.
Is Panasonic nanoe X expensive to maintain during HDB aircon servicing?
Panasonic's nanoe X emitter operates without consumable filter cartridges, though technicians must mask the ionizer connectors carefully before spraying coils with water or chemical solution. Routine servicing prices stay identical across three-room System 3 units when cleaned carefully.
Do both Panasonic CU-3XU28YBZ and Starmex MXY-3H28VG qualify for S$400 Climate Vouchers?
Both Panasonic CU-3XU28YBZ (MELS-PAN-AC220035) and Starmex MXY-3H28VG (MELS-MIT-AC190018) hold 5 NEA green ticks, letting qualifying HDB families deduct S$400 with Climate Vouchers until year-end 2027, paired with registered multi-split indoor units.
Which System 3 brand has faster repair parts availability after year five in Singapore?
Mitsubishi Electric Starmex enjoys broader independent spare-part stock across local Singapore suppliers for fan motors, thermistors, and boards, keeping post-warranty downtime short. Panasonic maintains dependable official Singapore supply, though niche XU control assemblies occasionally take extra ordering lead time.