Upgrading a Casement or Window Aircon to a 5-Tick Split

Replacing a casement or window aircon with a 5-tick inverter wall split cuts indoor compressor noise, seals off outdoor street dust, and lowers monthly SP Group bills. Older HDB flats just need clean trunking routes, proper condensate drainage, and compliant stainless steel brackets.

On this page

Why older HDB rooms move away from casement units

Window and casement aircons house the compressor and condenser fan directly inside the room opening, transmitting mechanical hum and vibration right next to the bed. Gaps around the window panel also admit tropical humidity, traffic noise, and warm outside air whenever the unit cycles off.

Moving the compressor outdoors onto a ledge or approved bracket leaves only a quiet indoor fan coil on the wall. Reclaiming the window opening lets natural daylight back in once the old frame is glazed or panelled shut.

Why older HDB rooms move away from casement units summary table
Upgrade areaOld window or casement unitNew 5-tick inverter split
Compressor locationBuilt into window frameMounted outside on ledge or bracket
Drainage pathRear tray or small hoseSloped PVC drain pipe to floor trap
Power supply13A plug or 15A switchDedicated 15A/20A isolator at condenser
Window sealingOpen cut-out panelNeeds glass or acrylic infill panel

Piping, drainage, and HDB bracket installation rules

Every split installation in an HDB block must be carried out by a BCA-trained aircon installer. Flats without a built-in aircon ledge require HDB-approved Grade 304 stainless steel brackets anchored with stainless steel bolts, and the installer must submit the installation report to HDB within 14 days.

Drainage deserves early planning during a window-to-split conversion. Because wall splits produce steady condensate in humid Singapore nights, the drain line must fall continuously toward a bathroom or kitchen floor trap rather than dripping onto the exterior facade.

Energy savings from 5-tick inverter wall splits

Older fixed-speed casement models slam on and off at full draw, spiking room electricity consumption across eight-hour sleeping cycles. Verified NEA 5-tick single-splits such as Daikin RKM25ZVMG (2.45 kW, S$255/yr NEA estimate) modulate inverter speed smoothly once the bedroom hits setpoint.

If two bedrooms currently run separate casement units, consolidating both onto a 5-tick System 2 such as Mitsubishi Electric MXY-2H20VF (4.51 kW, S$449/yr) avoids mounting multiple external brackets while reducing total running draw.

Common questions

Can a split aircon reuse the existing 13A wall socket from a window unit?
Wall-mounted split systems typically require a dedicated electrical circuit with an outdoor weatherproof isolator rather than plugging into a shared 13A bedroom socket. A licensed electrical worker should verify circuit capacity and install the proper isolator switch so the new condenser runs safely without tripping room circuits.
Who seals the leftover gap after removing an old casement aircon?
Aircon installers remove the old casement chassis and mount the new split system, while permanent glass pane replacement or aluminium window reinstatement is normally handled by a window contractor. Temporary acrylic or aluminium composite infill panels can close the opening cleanly until full window glazing is completed.
Is HDB approval needed before mounting external brackets for a split unit?
External condenser brackets on HDB blocks without built-in ledges must follow HDB structural specifications, use Grade 304 stainless steel fasteners, and be fitted by a BCA-trained installer. Filing the mandatory installation report after completion ensures ongoing compliance with HDB and BCA exterior facade safety inspections.