A bedroom wall unit in a Hougang HDB flat switches from crisp cooling to mild ambient airflow mid-evening while its green operation lamp begins blinking steadily. Toggling power at the wall switch clears the lamp briefly, yet the same warm-air shutdown returns within twenty minutes. Neighbouring rooms on the same system continue cooling normally.
- Setup
- Daikin Wall-mounted4-6 yearsHDBHougang
- Misread as
- Paying for trial-and-error refrigerant top-ups when a Hougang HDB bedroom aircon suddenly blows warm air with a flashing green light.
- Check first
- Pulling the stored fault family through Daikin remote Check mode before lifting covers, then confirming pipe thermistor resistance drift on a meter

What Else Produces This
A blinking green lamp on one Daikin fan coil means the control board has stored a specific fault code. Reading that code with the wireless remote first prevents guesswork gas charging.
Holding Cancel enters check mode and beeps on code C for unit 0, stepping to C4 for the pipe sensor.
Checking the outdoor condenser service valves shows dry, oil-free brass flares with zero frost or leak signs.
Lifting the indoor front cover exposes the copper pipe sensor clipped snugly into its coil pocket with intact wiring back to the indoor PCB.
Unplugging the thermistor harness and testing across the probe pins on a digital multimeter shows resistance drifted far off ambient room temperature tables.
Why It Happens
Continuous condensation cycles on a Singapore HDB bedroom evaporator coil expose the clipped pipe thermistor tip to constant moisture and cold-to-warm swings. Over four to six years of nightly cooling, moisture slowly creeps past the epoxy tip seal and shifts the sensor reading. The Daikin board interprets that skewed figure as a coil fault and halts cooling safely.
What Resolution Involves
Leave the healthy refrigerant charge and outdoor condensing unit completely untouched. Isolate power, unclip the drifted indoor pipe thermistor from its copper pocket, route a genuine matching Daikin sensor harness neatly along the factory channels, and seat the plug cleanly onto the indoor PCB header.
How to Tell It Worked
Restore power, clear the stored fault history, and run remote Check mode again to confirm a clean 00 double-beep readout. Test the Hougang bedroom unit on cool mode for thirty minutes, checking steady cold discharge air, smooth compressor modulation, and zero green-lamp blinking.
Before You Approve a Quote
Pull the stored remote code before guessing low gas
- Daikin wall units store exact fault families accessible right from the wireless remote Check mode before a single screw is removed.
- A C-series sensor readout directs inspection straight to the indoor coil thermistor instead of wasting money on unnecessary refrigerant charging.
- Swapping the drifted pipe thermistor restores crisp bedroom cooling in one visit with the sealed gas loop untouched.