What It Looks Like
Cooling stops outright in an older flat; the condenser perched on the aircon ledge starts briefly and cuts out with a sharp click. Before that, cooling thinned across humid months while electricity bills climbed.
Commonly misread as
Just the compressor, when the age of the system has already decided half of it.
What Separates the Causes
A short run and a click has two causes that look identical from outside: a starting component that cannot turn the motor, or a compressor that cannot turn at all. The cheap one is cleared first. On an ageing system, either answer raises a third question: the condition of everything else.
A starting component testing within range removes the cheap explanation.
A manual start that draws heavy current and trips protection within seconds is seizure, not a starting fault.
Thinned fins and corrosion across a third of the outdoor coil face mean the heat-shedding surface is already gone.
A worn indoor blower and an original control board put the rest of the system on the same clock.
A seized compressor sits sealed inside its welded casing, so nothing on site reverses it. On an older Singapore HDB system it seldom fails alone: the outdoor coil, blower and control board have endured the same hours under afternoon sun. Swapping one major part inside a tired set buys only the lifespan of the next weakest component.
What Fixes It and How to Verify
Two figures, both in writing. A swap covers the part, labour and a recharge, and leaves every other component on its original clock. A replacement costs more, resets warranty across the whole set, and draws less for the same cooling. Past twelve years the two figures converge, which makes the swap a poor buy at that age and a clear one at seven.
How to tell it worked
The quote carries both figures. A swap priced without a replacement figure beside it, and without a word on the coil, blower or board, has priced a part, not assessed a machine.
Before You Approve a Quote
The compressor is half the question on an old system
- Ask what else was inspected. A quote naming only the compressor has not looked at the coil, blower or board.
- Ask for both figures in writing. Past twelve years they usually land close enough that warranty decides it.
- A new system restarts the clock on every part. A swapped compressor restarts it on one.