Daikin aircon E2 error code
Use this Daikin E2 error code guide to confirm the source table meaning, capture the reporting equipment and model, and match the service manual before diagnosis. Match the model first; same-looking codes can point to different rows.
What does Daikin E2 mean?
Daikin E2 is listed as missing of earth leakage detection core, current-leakage detection or missing leakage-detection core, and earth-leakage detector activated in mixed model-family source rows, including VRV X RXQ-A(N)R cooling only, VRV IV+ REYQ / REMQ heat recovery, VRV 5 Heat Recovery REMA / REYA R32, VRV 5 Heat Pump RYMA / RXYA R32, and ERA-AYF AHU / air curtain. The loaded row is source-backed by official diagnostic material. Do not collapse this code across model families; use the model, series, or system type to choose the right row. Confirm the exact model, series, or signal row before accepting a parts quote.
Choose the matching source row
The same visible code has more than one source-backed meaning. Match the model family, system type, or reporting unit before approving parts.
| Code | What it means | What to check first |
|---|---|---|
| SM-TS3 matrix overview | Missing of earth leakage detection core | Match this row to the installed model or reporting unit, then use the source-specific checks below. |
| VRV X RXQ-A(N)R cooling only | Current-leakage detection or missing leakage-detection core | Match this row to the installed model or reporting unit, then use the source-specific checks below. |
| E2-01 - master / E2-02 - slave 1 / E2-03 - slave 2 | Earth-leakage detector activated | Restart the unit. If the problem reoccurs, contact the dealer. Match the alternating E2-01 display to the master source row. |
| E2-06 - master / E2-07 - slave 1 / E2-08 - slave 2 | Earth-leakage detector malfunction: open circuit at A1P connector X101A | Check the connection on the PCB or actuator. Match the alternating E2-06 display to the master source row. |
| VRV 5 Heat Recovery R32 - E2 / VRV 5 Heat Pump R32 - E2 | Outdoor current-leakage detector activated | Check the earth-leakage detector and its PCB connection before returning the unit to service. |
| ERA-AYF AHU / air curtain | Earth-leakage detector activation or detector circuit fault (E2-01/06) | Match this row to the installed model or reporting unit, then use the source-specific checks below. |
What to do now
Use these steps to record evidence and match the installed model to its service manual before diagnosis or a repair quote.
Record E2 and match the service manual
Record E2 and stop there; the source table gives no customer reset procedure. Arrange diagnosis with the matching service manual.
No manufacturer reset steps listed for E2
Capture the complete E2 error code and model stickers first. The source table lists the meaning but no customer reset procedure; do not treat a generic power-cycle as manufacturer guidance.
Send these to us
E2 error code, a clear display photo, Daikin indoor and outdoor model stickers, the controller, gateway, or unit that reported the code, operating mode and affected area, and any power or setting changes made after the code appeared
Source-specific guidance
These diagnostic-reference notes help match the code to the exact model. Electrical, refrigerant, wiring, resistance, and component checks are technician work, not DIY steps.
| Source detail | What it says |
|---|---|
| Singapore / model note | Official Daikin SM-TS3 page-1 matrix row. The matrix gives the broad malfunction wording, but not the detailed cause table; confirm the exact model and installed accessories before treating it as final. |
| Singapore / model note | Official Daikin RXQ6-48A(N)R cooling-only service-manual row. Confirm the installed model and matching regional manual before diagnosis; this source is not claimed as universal across every Daikin VRV generation. |
| Singapore / model note | Official Daikin 4PEN561154-1C overview row for REYQ8~20 and REMQ5U7Y1B VRV IV+ heat-recovery systems. The guide refers technicians to the service manual for the complete code list and detailed troubleshooting. |
What to check before repair
The source table establishes the code meaning, not a repair procedure. Capture evidence first; model-specific tests belong to the matching service manual.
| You can check | Technician should confirm |
|---|---|
| Photograph the complete E2 error code before taking any action. | Confirm E2 exactly and record which controller, gateway, or unit reported it. |
| Capture the Daikin indoor and outdoor model stickers and identify which controller or unit reported it. | Match the indoor and outdoor model stickers, installed family, and reporting equipment to the source scope. |
| The source table provides no customer reset procedure. Preserve the evidence and use the matching service manual for any system action. | Follow the matching service-manual procedure and keep measured test evidence before naming a failed part. |
Source-bounded repair decision
Daikin E2 confirms the source-table fault label, not a failed part or repair procedure. Match the installed model to its service manual and require measured diagnostic evidence before approving parts, settings, or refrigerant work.
Whether the reporting controller or unit and exact installed model are confirmed.
What the matching service-manual procedure and measured tests show.
Whether the proposed repair names the evidence for the failed part or condition.
Daikin E2 questions
What does the Daikin E2 error mean?
Can I fix a Daikin E2 error myself?
Is it safe to keep running the aircon with an E2 error?
What causes a Daikin E2 error?
Will a Daikin E2 error need a repair or a full replacement?
What should I send a technician about a Daikin E2 error?
Confirm the fault
Share the error code, model number and symptoms so we can assess the likely cause.
Not the right code?
Browse the full Daikin list or check a few codes in the same fault category.
Ready to get started?
Tell us what’s going on. Symptoms, setup, photos, anything we should know. We’ll assess and come back with the right next step.
Read next
Use this quote-check guide only after the matching service manual identifies the diagnostic path.