Daikin Aircon PCB Repair in Singapore
A Daikin that has power but will not start, keeps restarting or shows a communication code may need a new board, or only a smaller fix to its wiring or controls. We test the supply, wiring, sensors and connected parts before quoting a replacement board.
On-site check: $30 / visit. Visit fee waived if you proceed with the quoted work.
Signs Your Daikin Aircon Needs a PCB Check
The Unit Has Power but Will Not Start
Lights or the controller may still respond while the indoor unit, outdoor unit or both refuse to run normally.One Room or the Whole System Stops Responding
The pattern across rooms helps separate an indoor-board problem from an outdoor or shared communication fault.A Communication or Board-Related Error Appears
Service Scope
Find the cause
We check power, wiring and sensors to isolate the fault. Depending on the model, we test the indoor and outdoor boards or inverter drive.
Confirm the repair and quote
We quote the repair and confirm parts and lead time before you approve. If the board has failed, we replace it with one of the same revision and test startup, controls and communication after fitting.
Workmanship Warranty
Labour
30-day workmanship warranty. If the same fault returns from our repair, we come back and the labour is on us, with no second on-site check fee.
Parts
Parts carry the distributor's warranty for that component, so the term varies by part. We tell you both terms before you approve the work.
Photos from Recent Jobs
What Customers Say
“Great people and process. Booked their $30 check when my air conditioner could not switch on. They traced the problem to wiring. No upsell, no drama. Repair done same day, check fee waived. Everything upfront, no hidden cost. Definitely would use their services again! 5/5”
Yong Jun YeoGoogle “The installer for my new aircon had done a brillant job and the communication had been seamless as well. I am happy in engaging their service!😄”
cz0903Carousell “Repeated the chemical wash today. Their professional team made sure there was minimal mess and dirt during the process. Can really feel the difference, the aircon feels much better after the servicing. Very satisfied with their service!”
jonathan limGoogle “they are amazingly on time, and very upfront on the prices. Friendly disposition and they provided valuable advices. i like how that they only sell what you need. Just awesome!”
makchique_specsCarousell “Customer service was prompt and responsive throughout. Guys came on time, helped to advise on the proper cleaning and relocation, even helped me to save money. Highly recommended!”
A NGoogle “The guys at Snowflake go above & beyond in terms of customer service. I had contacted them due to my aircon unit leaking. The guys spent an hour doing chemical clean. However my unit starting leaking again that night. Snowflake were extremely proactive by sending same guys next guy to fix the problem. They located pipe outside & cleared it. Really highly recommend 👍🏼🤩”
nazzasgCarousell “For our 1 year contract, we are satisfied with the efficiency and skilled of the technicians who maintained our aircon. Easy to schedule and coordinate. Hence, we will re contract for another year. Thanks for your service.”
Marian ArcaoGoogle “Fast and efficient service! 100% satisfied with the fast work! Arrived on time and work done was very professional for our commercial unit! Even provide us with new controller (at a price) cause ours didnt work anymore! 😔”
baecaresgCarousell “Used them a few times, very pleased with service level and prices. They provide honest advice on what is needed or not. Plus, they always bring a tarp to cover surfaces. No dodgy upselling practices. Recommended. Will continue to engage their service.”
HW LGoogle “Angeline is very patient in answering all my queries via chat. Tony came to check and does the necessary and give really good recommendation and advices on what is really needed to be done. Recommended 👍”
lill.yCarousell “Excellent Experience Installing System 3 Air Conditioner Knowledgeable, flexible, and efficient service.”
David NgGoogle “Excellent service, able to solve our problem with the aircon removal professionally and goes the extra mile to help us! Would recommend 101%! 💯💯”
kullookCarousell “Mr Yi Tat & Mr Kian were very efficient at servicing 4 ACs within 2 hours! They were very friendly and extremely easy to communicate with throughout the process. Will definitely call them back for future servicing. Thank you, gentlemen!”
Murshidah MunibGoogle “Engaged them because of good reviews and truly they deserved the good reviews. Tony and Ian were able to rectify my problems (other technician was not able to pin point the fault). Repaired and service with resonable charges. Thanks Tony and Ian for solving my issue. 🙏”
ngeokhimCarousell “My go to Aircon servicing for years on. Always prompt in responses and punctual on day if servicing. If delays are expected, they will update via WhatsApp. Never upsell and is honest and dependable. I always have Yen for my servicing. great guy!”
Joanne CGoogle “Technician came within the time frame that they provided and the technician even go extra miles in cleaning and wiping the surrounding areas after chemical wash. Servicing is indeed good”
SharonnczyCarousell “The technician explained their solution thoroughly and their price is transparent. Recommended”
Zi Hao TanGoogle “trusted,easy&fast reply..e service was excellent..e servicing man advice abt my aircon..no messy dust..👍 now my 3 unit aircon getting much colder...tqsm..(will deal wif u again)❤”
idaomrsleeCarousell “Great service! The response was very fast and they arranged the repair quickly. The technician was experienced and knew exactly what to do. Everything was fixed efficiently and the pricing was very reasonable. Definitely value for money—highly recommended!”
Alex LuGoogle “Thumbs up for snowflake aircon service. Delayed a bit on the arrival but they are able to inform prehand. Their guys are very professional to recommend what's the best solution for me. Reasonable price with quality work. Will surely engage them again :)”
ivanaviCarousell “My family has been going back to them for 10 years+. Service is always amazing and the people are very friendly 🤗🤗”
naurahGoogle “Prompt arrival and professional service. Been engaging them for 3 years now. Highly recommend! 👍”
luckyzackyCarousell
Checks, models and error codes
Is Daikin PCB Repair Worth It?
Replacing the PCB is usually sensible when the rest of the system is healthy, the exact board revision is available and testing has ruled out wiring, sensors and connected loads.
| System age | Usual call |
|---|---|
| Under 5 years | Almost always worth repairing. |
| 5–8 years | Repair is still the default for most faults. |
| 8–12 years | Depends on the fault. |
| Over 12 years | Major component failures usually favour replacement. |
Reasons for each row: full Daikin table.
You can wait
Testing finds a loose connector or a bad sensor. Fix that and keep the board.
Do not wait
The compressor fails to start on most attempts. A failing board does not recover, and an intermittent fault becomes permanent.
On-site check $30 / visit, waived if you go ahead with the quoted repair. Rates as of 20 Nov 2026. See our aircon system replacement process.
A Board-Related Code Does Not Always Mean a Failed PCB
Power or Wiring Fault
Loose terminals, a damaged interconnect or unstable supply can produce board and communication errors.Sensor or Connected Load
A shorted thermistor, motor or valve can pull down a healthy board or make its input look incorrect.Inverter Power Stage
On inverter systems, the main control PCB and the IPM or driver circuit are tested as separate failure points.
What Is Different on Daikin Systems
Daikin inverter efficiency depends on more control electronics. On systems past about eight years, the indoor board, outdoor board and inverter power stage must be separated before a replacement is approved.
Examples of Daikin Systems We Check
iSmile CTKS / CTKB and MKS Multi-Split Systems
iSmileEco CTKM / CTKP and EZi CTKC Systems
iSmart ENVi FTKM Single-Split Systems; SkyAir or VRV Scope Confirmed from the Exact Model
Model not listed
Message us the error code or what the unit is doing. A photo or short video helps if you have one.
Parts and timing
Current residential Daikin parts are well supported locally, but an inverter board or compressor on an older MKS system can materially change the repair decision.
Daikin Error Codes Related to PCB Problems
Choose where the code appeared on your unit.
Indoor unit or controller9 guides
- A1Indoor PCB defectiveness; Malfunction of indoor unit PCB
- A7Indoor swing-flap motor malfunction
- A8Power supply voltage abnormality
- C1Failure of transmission between indoor PCB and sub PCB; Transmission error involving the indoor unit PCB, fan PCB, or auto-grille control PCB
- U4Failure of transmission between indoor and outdoor unit; Transmission fault between indoor and outdoor unit
- U5Transmission fault between indoor unit and remote controller; Transmission error between the remote controller and indoor unit
- U8Transmission fault between remote controllers; Transmission error between main and sub remote controllers
- UETransmission fault between indoor unit and centralized control equipment; Transmission error between the centralized controller and indoor unit
- UFIndoor-to-BS-unit wiring or piping mismatch; Indoor-to-SV-unit wiring or piping mismatch
Outdoor unit12 guides
- E1Circuit board fault; Defective outdoor unit PCB
- E2Current-leakage detection or missing leakage-detection core
- H3Harness abnormality between the outdoor main PCB and inverter PCB
- L1Malfunction of inverter PCB; Inverter PCB abnormality
- L2Momentary power failure during test operation
- L5Inverter instantaneous overcurrent (DC output); Inverter PCB fault
- LCTransmission fault between control PCB and inverter PCB; Transmission error between the inverter PCB and outdoor main PCB
- P1Power voltage imbalance or inverter PCB; Power-supply voltage imbalance
- U2Power supply insufficient or instantaneous abnormality; Insufficient inverter supply voltage
- U3Check operation not executed or transmission error; Test run aborted because of communication issues
- U7Transmission fault between outdoor units or outdoor storage unit; Transmission error between outdoor units
- U9Transmission fault in another system; Another indoor unit on the same F1/F2 line has an error, but the EKVDX or indoor unit can still operate
Whole-system faults5 guides
Codes that depend on the exact model11 guides
- AJMalfunction of capacity setting on indoor unit PCB
- L0Malfunction of inverter system
- L3Electrical parts heat fault
- L4High temperature at inverter circuit heatsink; Malfunction of inverter radiation fin temperature rise
- L6Inverter instantaneous overcurrent (AC output)
- LAMalfunction of power transistor
- M1Malfunction of central remote controller PCB
- M8Transmission fault between optional centralized-control controllers
- PJImproper combination between inverter and fan driver; Malfunction of capacity setting on outdoor unit PCB
- U6Transmission fault between indoor units
- UJTransmission fault with accessory device
Every code is in the full lookup for this brand. Last reviewed 2026-08-21.
Other Daikin Repair Checks
Find the service that matches a different fault on the same brand of aircon.
Frequently Asked Questions
How do you confirm a Daikin PCB fault?
Is a Daikin error code enough to order the PCB?
Should I repair or replace my Daikin aircon?
Ready to Get Started?
Include model and error code or light.